www.eravant.com | 424-757-0168 | support@eravant.com Copyright © 2023 by Eravant Final Rev 1.0 K-Band Balanced Up-Converter SFU-42-N1 is a K Band balanced up-converter that utilizes high performance GaAs Schottky beam-lead diodes and a balanced circuit configuration to offer superior RF performance. The up-converter supports the full waveguide band operation for both LO and RF frequencies from 18 to 26.5 GHz with an IF output from DC to 8.5 GHz. The mixer offers a conversion loss of 6.0 dB typical and a high RF to LO port isolation of 30 dB. Electrical Specifications: Mechanical Specifications: Parameter Minimum Typical Maximum RF Frequency 18 GHz 26.5 GHz LO Frequency 18 GHz 26.5 GHz IF Frequency DC 8.5 GHz LO Pumping Power +10 dBm +13 dBm +15 dBm Conversion Loss 6 dB IF Input P1dB -5 dBm RF to LO Isolation 30 dB Combined IF and LO Power +18 dBm Specification Temperature +25°C Operating Temperature -40°C +85°C Item Specification RF Ports WR-42 Waveguide with UG-595/U Flange LO Ports WR-42 Waveguide with UG-595/U Flange IF Port SMA (F) Case Material Aluminum Finish Gold Plated Weight 1.3 Oz Outline FB-NK ECCN EAR99
FEATURES
- Full Waveguide Band Coverage
- Low Conversion Loss
- High IF Frequency up to 8.5 GHz
APPLICATIONS
- Radar Systems
- Communication Systems
- Test Equipment SUPPLEMENTAL DETAILS
www.eravant.com | 424-757-0168 | support@eravant.com Copyright © 2023 by Eravant Final Rev 1.0 Mechanical Outline: (Unless otherwise specified, all dimensions are in inches [millimeters]) -10 18 19 20 21 22 23 24 25 26 Conversion Loss (dB) Frequency (GHz) Typical Conversion Loss vs. Frequency RF: -20 dBm; LO: +13 dBm Conversion Loss (LO @ 18 GHz) Conversion Loss (LO @ 22 GHz) Conversion Loss (LO @ 26.5 GHz)
www.eravant.com | 424-757-0168 | support@eravant.com Copyright © 2023 by Eravant Final Rev 1.0 NOTE:
- All data presented is collected from a sample lot. Actual data may vary unit to unit slightly.
- All testing was performed under +25 oC case temperature.
- Eravant reserves the right to change the information presented without notice. CAUTION:
- Exceeding absolute maximum ratings shown will damage the device.
- The device is static sensitive. Always follow ESD rules when working with the device.
- The IF port of the mixer is DC coupled. Use a DC block when connecting to other devices.
- Never apply an external bias voltage to the IF port because the mixer will be damaged.
- If a waveguide is present, any foreign objects in the waveguide will cause performance degradation and may damage or destroy the unit. (0.90 ± 0.02 Nm). Torque wrench model SCH-08008-S1 is highly recommended.