www.eravant.com | 424-757-0168 | support@eravant.com Copyright © 2023 by Eravant Final Rev 1.1 WR-12 Amplitude Detector, Positive Output SFD-603903-12SF-P1-M is a WR-12 amplitude detector that can be used for full or narrow band applications. The detector is zero biased and intended for small signal detection purposes. The detector exhibits high sensitivity characteristics across the full waveguide operating bandwidth. The detector is designed to have a 10 MHz video bandwidth and a 1 MΩ video output impedance. Electrical Specifications: *Note: The sensitivity is for the input signal level -20 dBm or below. Mechanical Specifications: Parameter Minimum Typical Maximum Frequency 60 GHz 90 GHz Sensitivity* 3000 mV/mW RF Input Power -20 dBm RF Power Handling +10 dBm Video Bandwidth 10 MHz Detection Speed, Rise Time (50 Ohm Load) 5 Nano Seconds Output Voltage Polarity Positive Specification Temperature +25 ˚C Operating Temperature 0 ˚C +50 ˚C Item Specification RF Port WR-12 Waveguide with UG-387/U-M Anti-Cocking Flange DC Port SMA (F) Case Material Aluminum Finish Gold Plated Weight 0.4 Oz Outline FD-E3-A ECCN EAR99
FEATURES
- Full Waveguide Band Operation
- High Sensitivity
APPLICATIONS
- Test Instrumentations SUPPLEMENTAL DETAILS
www.eravant.com | 424-757-0168 | support@eravant.com Copyright © 2023 by Eravant Final Rev 1.1 100 1000 10000 60 65 70 75 80 85 90 Sensitivity (mV/mW) Frequency (GHz) Sensitivity vs. Frequency RF: -20 dBm 100 200 300 400 500 600 -25 -20 -15 -10 -5 Vout (mV) Input Power (dBm) Typical Detected Voltage vs. Input Power
60 GHz
75 GHz
90 GHz
www.eravant.com | 424-757-0168 | support@eravant.com Copyright © 2023 by Eravant Final Rev 1.1 Mechanical Outline: (Unless otherwise specified, all dimensions are in inches [millimeters]) NOTE:
- On condition that test data is provided it is collected from a sample lot. Actual data may vary slightly from unit to unit. All testing is performed under +25 °C room temperature.
- The amplitude detector is a small signal detector. The sensitivity shown is for RF signal -20 dBm or lower.
- Eravant reserves the right to change the information presented without notice. CAUTION:
- Exceeding absolute maximum ratings will damage the device.
- The device is static sensitive. Always follow ESD rules when working with the device.