www.eravant.com | 424-757-0168 | support@eravant.com Copyright © 2023 by Eravant Final Rev 1.0 2-Way Coaxial Power Splitter, 5 to 65 GHz SCS-0536533816-VFVF-27 is a coaxial 2-way power splitter with a typical insertion loss of 3.8 dB at each output port and a typical isolation of 16 dB across the frequency range of 5 to 65 GHz. The power splitter has a power handling of 5W (CW) and a typical amplitude unbalance of 0.6 dB. The return loss for all ports is 11 dB typical. The RF connectors of the power splitter are female 1.85 mm (V) female connectors. Electrical Specifications: *Note: The insertion loss is circuit loss, which does not include the power dividing loss. Mechanical Specifications: Parameter Minimum Typical Maximum Frequency Range 5 GHz 65 GHz Insertion Loss* 3.8 dB Amplitude Unbalance 0.6 dB Phase Unbalance 6.0 Port Isolation 16 dB Return Loss 11 dB Forward Power Handling 5 W (CW) Impedance 50 Specification Temperature +25 °C Operating Temperature -40 °C +85 °C Item Specification RF Connectors 1.85 mm (V) Female Case Material Aluminum Finish Black Paint Outline CS-V2-Z1 ECCN EAR99
FEATURES
- Low Insertion Loss
- High Isolation
- Compact Package
APPLICATIONS
- Test Labs
- Sub-assemblies
- Instrumentations SUPPLEMENTAL DETAILS
www.eravant.com | 424-757-0168 | support@eravant.com Copyright © 2023 by Eravant Final Rev 1.0 -25 -20 -15 -10 -25 -20 -15 -10 5 10 15 20 25 30 35 40 45 50 55 60 65 Isolation (dB) Insertion Loss (dB) Frequency (GHz) Typical Insertion Loss and Isolation vs. Frequency Insertion Loss Isolation -60 -55 -50 -45 -40 -35 -30 -25 -20 -15 -10 -60 -55 -50 -45 -40 -35 -30 -25 -20 -15 -10 5 10 15 20 25 30 35 40 45 50 55 60 65 Output Return Loss (dB) Input Return Loss (dB) Frequency (GHz) Typical Return Loss vs. Frequency Input Return Loss Output Return Loss
www.eravant.com | 424-757-0168 | support@eravant.com Copyright © 2023 by Eravant Final Rev 1.0 Mechanical Outline: (Unless otherwise specified, all dimensions are in inches [millimeters]) -20 -15 -10 -20 -15 -10 5 10 15 20 25 30 35 40 45 50 55 60 65 Phase Unbalance (deg) Amplitude Unbalance (dB) Frequency (GHz) Amplitude and Phase Unbalance vs. Frequency Amplitude Unbalance Phase Unbalance
www.eravant.com | 424-757-0168 | support@eravant.com Copyright © 2023 by Eravant Final Rev 1.0 NOTE:
- All data presented is collected from a sample lot. Actual data may vary slightly from unit to unit.
- All testing is performed under +25 °C case temperature.
- Eravant reserves the right to change the information presented without notice. CAUTION:
- Exceeding absolute maximum ratings shown will damage the device. recommended.