www.eravant.com | 424-757-0168 | support@eravant.com Copyright © 2023 by Eravant Final Rev 2.0 WR-10 Waveguide Cable, Flexible, 12” Long SCG-10120-F1 is a 12” long WR-10 waveguide cable. The frequency range of the waveguide cable is 75 to 110 GHz. The cable allows for varied orientations of waveguide to waveguide connections. The cable has a typical insertion loss of 8.5 dB and a nominal return loss of 14 dB. The cable is flexible with minimum bend radius of 0.250”. Other lengths are offered under different model numbers. Electrical Specifications: Mechanical Specifications: Parameter Minimum Typical Maximum Frequency 75 GHz 110 GHz Insertion Loss 8.5 dB Return Loss 14 dB Power Handling 2 W (CW) Specification Temperature +25°C Operating Temperature -40°C +85°C Item Specification Minimum Bending Radius 0.250” Waveguides WR-10 with UG-387/U Flange Waveguide Material and Finish Gold Plated Aluminum Cable Connectors 1 mm Male Connector Material Passivated Stainless Steel Cable Material Fluorinated Ethylene Propylene (FEP) Cable Outer Diameter 0.058” Length 12.0” Weight 1.5 Oz Outline CW-RWRW-FS-L ECCN EAR99
FEATURES
- Full Band Coverage
- High Return Loss
- Flexible and Durable
APPLICATIONS
- Test Lab
- Sub-assemblies SUPPLEMENTAL DETAILS
www.eravant.com | 424-757-0168 | support@eravant.com Copyright © 2023 by Eravant Final Rev 2.0 Mechanical Outline: (Unless otherwise specified, all dimensions are in inches [millimeters]) -35 -30 -25 -20 -15 -10 -35 -30 -25 -20 -15 -10 75 80 85 90 95 100 105 110 Return Loss (dB) Insertion Loss (dB) Frequency (GHz) Typical Performance vs Frequency Insertion Loss Return Loss
www.eravant.com | 424-757-0168 | support@eravant.com Copyright © 2023 by Eravant Final Rev 2.0 NOTE:
- Length “L” can be customizable.
- On condition that test data is provided it is collected from a sample lot. Actual data may vary slightly from unit to unit. All testing is performed under +25 °C room temperature.
- On condition that simulated test data is provided, actual measured data may slightly vary.
- Eravant reserves the right to change the information presented without notice. CAUTION:
- Bending the cable sharply will either cause damage or degrade the performance of the cable.
- Exceeding absolute maximum ratings shown will damage the device.
- If a waveguide is present, any foreign objects in the waveguide will cause performance degradation and may damage or destroy the unit. (0.90 ± 0.02 Nm). Torque wrench model SCH-08008-S1 is highly recommended.