SAS-124-09408-F1 ERAVANT | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 4

Technical content

www.eravant.com | 424-757-0168 | support@eravant.com Copyright © 2023 by Eravant Final Rev 1.2 WR-08 Linear to Circular Polarizer, 90-140 GHz SAS-124-09408-F1 is a F band, linear to circular polarizer that operates from 90 GHz to 140 GHz. The polarizer offers a typical insertion loss of 0.5 dB, typical axial ratio of 1.2, and a typical return loss of 20 dB. The polarizer is fixed and can be used for either right-handed or left-handed polarization based on the direction of the input signal. The polarizer is often combined with Eravant’s rectangular to circular waveguide transition (SWT-08094-SB) and WR-08 conincal antenna (SAC-2309-094-S2) for various system applications. Electrical Specifications: Mechanical Specifications: Parameter Minimum Typical Maximum Frequency Range 90 GHz 140 GHz Insertion Loss 0.5 dB Axial Ratio 1.2 Return Loss 20 dB Specification Temperature +25°C Operating Temperature -40°C -85°C Item Specification RF Ports Ø0.094” Waveguide with UG-387/U-M Anti-Cocking Flange Material Brass Finish Gold Plated Weight 0.07 Oz Outline AS-FFF-094-A ECCN EAR99

FEATURES

  • Broad Band Coverage
  • Compact Size
  • Good Axial Ratio

APPLICATIONS

  • Antenna Ranges
  • Waveguide Polarization Selection
  • Communication Systems SUPPLEMENTAL DETAILS

www.eravant.com | 424-757-0168 | support@eravant.com Copyright © 2023 by Eravant Final Rev 1.2 -70 -65 -60 -55 -50 -45 -40 -35 -30 -25 -20 -15 -10 -4.5 -3.5 -2.5 -1.5 -0.5 90 95 100 105 110 115 120 125 130 135 140 Return Loss (dB) Insertion Loss (dB) Frequency (GHz) Measured Insertion Loss, Return Loss Vs Frequency Insertion Loss Return loss 0.2 0.4 0.6 0.8 1.2 1.4 1.6 1.8 2.2 2.4 2.6 2.8 3.2 3.4 3.6 3.8 4.2 4.4 4.6 4.8 90 95 100 105 110 115 120 125 130 135 140 Axial Ratio Frequency (GHz) Measured Axial Ratio Vs Frequency

www.eravant.com | 424-757-0168 | support@eravant.com Copyright © 2023 by Eravant Final Rev 1.2 Mechanical Outline: Unless otherwise specified, all dimensions are in inches [millimeters]) NOTE:

  • Test data provided is collected from a sample lot. Actual data may vary slightly from unit to unit. All testing is performed under +25 °C room temperature.
  • Eravant reserves the right to change the information presented without notice. CAUTION:
  • Any foreign objects in the antenna will cause performance degradation and possible device damage.

www.eravant.com | 424-757-0168 | support@eravant.com Copyright © 2023 by Eravant Final Rev 1.2 LHCP and RHCP Polarization Configuration Notes and Diagram:

  • The polarizer’s product label indicates the direction of Left-Handed Circular Polarization (LHCP).
  • An example configuration diagram is provided below. The diagram indicates the input and output ports and the orientation in which the polarizer is to be attached to the rest of the components to obtain an LHCP signal at the output port.
  • The polarizer can be configured to obtain a Right-Handed Circular Polarized (RHCP) signal at the output port by reversing the input and output ports as shown in the second diagram.