TIS TRACOPOWER | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 12
Technical content
Features
◆ Switch mode power supplies for DIN-rail mount ◆ 6 power ranges with 2, 3, 6, 12, 20 and
24 A output current (24 VDC models)
◆ Selectable 1 15/230 VAC input ◆ Very low ripple and noise ◆ EMI complies with EN 61000-6-3 and EN 61000-6-4 ◆ Operating temp. range –25°C to +70°C ◆ For system operation available with built-in functions: RED: Redundancy module for N+1 Systems with true current sharing SIG: Signal module with AC-power- fail, power good signal and external On/Off control UDS: DC-UPS module for uninter- ruptable battery backed-up power systems ◆ Worldwide safety approvals incl. class I, div. 2 location ◆ Easy snap-on mount on DIN-rails or chassis mount ◆ 3-year product warranty The switching power supplies of the TIS series have been particularly designed for applications in industrial process control systems and with machine tools. Excellent specifications and high immunity against electrical disturbances guarantee reliable power for sensitive loads in rugged industrial environments. With the help of op - tional function modules specific requirements for system applications can be easily realized with a standard model. With the UDS module the power supplies can be extended to a perfect DC-UPS with automatic battery- backup. This function is very often required in applications where a time delayed shutdown of a system is neces- sary. To monitor and control the power supply a signal module can be installed. For parallel operation with active power sharing a redundancy option is available. This flexibility makes the TIS series power supplies a cost effective solution for many industrial applications. Order Code Input Voltage Output Power Output Voltage Output Current (includes terminal plugs) nom. max. nom. max. TIS 50-112 115 –24 0 VAC 50 W 12 VDC 3.5 A TIS 50-124 universal input 24 VDC 2.0 A TIS 75-112 115/23 0 VAC 12 VDC 6.0 A TIS 75-124 selectable 75 W 24 VDC 3.0 A TIS 75-148 48 VDC 1.5 A TIS 150-124 115/23 0 VAC 150 W 24 VDC 6.0 A TIS 150-148 selectable 48 VDC 3.0 A TIS 300-124 115/23 0 VAC 24 VDC 12.0 A TIS 300-148 selectable 300 W 48 VDC 6.0 A TIS 300-172 72 VDC 4.2 A TIS 500-124-115 115 VAC 500 W 24 VDC 20.0 A TIS 500-124-230 230 VAC 500 W 24 VDC 20.0 A TIS 600-124 24 VDC 24.0 A TIS 600-148 115/23 0 VAC 600 W 48 VDC 12.0 A TIS 600-172 selectable 72 VDC 8.5 A Models CB Scheme (LVD) UL 60950-1 UL 62368-1 UL 508 UL 1604
http://www.tracopower.com Page 2 of 12 Industrial Power Supplies TIS Series 50–600 Watt Input Specifications Input voltage range TIS 50: 93 – 264 VAC TIS 75, 150, 300, 600: 93 – 132 VAC / 187 – 264 VAC TIS 500 -124-230. 187 – 264 VAC TIS 500-124-115: 93 – 132 VAC Input frequency 47 – 63 Hz Input current at full load (typ.) at 1 15 VAC at 230 VAC TIS 50: 0.85 A 0.50 A TIS 75: 1.3 A 0.75 A TIS 150: 2.7 A 1.6 A TIS 300: 4.9 A 2.9 A TIS 500: 6.0 A 4.3 A TIS 600: 7 .0 A 5.0 A Recommended circuit breaker, TIS 50: 5.0 A characteristic C TIS 75: 5.0 A or fuse, slow blow typ TIS 150: 10.0 A TIS 300: 15.0 A TIS 500: 15.0 A TIS 600: 20.0 A Output Specifications Output voltage adj. range 12 VDC models: 12 – 14 VDC
24 VDC models: 24 – 28 VDC
48 VDC models: 48 – 52 VDC
72 VDC models: 60 – 76 VDC
Regulation – Input variation 0.2 % – Load variation (10–90%) TIS 50, TIS 75, TIS 150: 1.0 % TIS 300, TIS 500, TIS 600: 0.3 % (2.0 % in parallel operation) Ripple and noise (20MHz bandwidth) <50 mV pk-pk Electronic short circuit protection current limitation at 1 10 % typ. (constant current, automatic restart) Over voltage protection, trigger point at 140 % typ. Vout nom. Hold-up time 1 15 VAC 230 VAC TIS 500: min. 20 ms min. 40 ms TIS 600: min. 15 ms min. 25 ms
http://www.tracopower.com Page 3 of 12 General Specifications Temperature ranges – Operating (ambient temp.) –25°C to +70°C – Derating above 50°C (122°F) 2 %/K – Storage (non operating) –25°C to +85°C Humidity (non condensing) 95 % rel. H max. Pollution degree 2 Temperature coefficient 0.02 %/K Altitude during operation 2’000 m max. Switching frequency 80 kHz typ. (pulse width modulation) Efficiency TIS 50 ... TIS 300: 85 % typ. TIS 500: 90 % typ. TIS 600: 90 % typ. Isolation according to IEC/EN 60950, UL 60950, UL 508 Reliability, calculated MTBF TIS 50/75: 450’000 h / 420’000 h (MIL-HDBK-217F, at +25°C, ground benign) TIS 150/300: 420’000 h / 360’000 h TIS 500/600: 340’000 h / 300’000 h Safety standards IEC/EN 60950-1 (SELV, except 72 VDC models) UL/cUL 60950-1, UL 508, UL/cUL 1604 Safety approvals – CB report for IEC 60950, IEC 62368-1 – UL approvals UL/cUL 60950, File e181381 UL 62368-1 UL/cUL 508, File e210002 UL/cUL 1604, File e213613 not for TIS 50 & 500 (Class I, Div. 2, Groups A, B, C and D hazardous locations) www.ul.com -> certifications – CSA certificate UL 60950-1, CSA 60950-1 – Certification documents www.tracopower.com/overview/tis Electromagnetic compatibility (EMC), Emissions EN 61000-6-3 / EN 61000-6-4 – Conducted RI suppression on input EN 5501 1 class B, EN 55022 class B, FCC part 15, level B – Radiated RI suppression EN 5501 1 class A, EN 55022 class A, FCC part 15, level A Electromagnetic compatibility (EMC), Immunity EN 61000-6-2 – Electrostatic discharge (ESD) IEC/EN 61000-4-2 4 kV/8 kV – Radiated RF field immunity IEC/EN 61000-4-3 10 V/m – Electrical fast transient / burst immunity IEC/EN 61000-4-4 2 kV – Surge immunity IEC/EN 61000-4-5 2 kV/4 kV – Immunity to conducted RF disturbances IEC/EN 61000-4-6 10 V – Power frequency field immunity IEC/EN 61000-4-8 30 A/m Safety class degree of electrical protection 1 (IEC 536) Case protection IP 20 (IEC 529) Environment – Vibration IEC 60068-2-6; 1 gn, 200 sweeps, each axis – Shock IEC 60068-2-27; 15 gn, 1 1 ms, each axis Enclosure material aluminium (chassis) / zinc plated steel (cover) Mounting (snap-on with self locking spring) for 35 mm DIN-rails as per EN 50022 Connection detachable screw terminal block (plugs included) (TIS 600: fixed screw terminal block) Industrial Power Supplies TIS Series 50–600 Watt Instruction manual can be downloaded under: www.tracopower.com/overview/tis All specifications valid at nominal input voltage, full load and +25 °C after warm-up time unless otherwise stated.
http://www.tracopower.com Page 4 of 12 Power Supplies with Redundancy Function With this option a parallel operation of up to 5 units is possible. Decoupling diodes and current share lines allow to build true N +1 redun- dant systems with active current sharing for all units. This function also includes an alarm relay to signal a single unit failure. This option is available for TIS 150 W, TIS 300 W and TIS 600 W models. Please note: This option cannot be combined with other options. Industrial Power Supplies TIS Series 50–600 Watt Order Code Input Voltage Output Power Output Voltage Output Current (includes terminal plugs) max. nom. max. TIS 150-124 RED 115/230 VAC 150 W 24 VDC 6.0 A TIS 150-148 RED selectable 48 VDC 3.0 A TIS 300-124 RED 115/230 VAC 300 W
24 VDC 12 A
TIS 300-148 RED selectable 48 VDC 6.0 A TIS 600-124 RED 115/230 VAC 600 W
24 VDC 24 A
TIS 600-148 RED selectable 48 VDC 12 A Models I-Sense Regulator L Con1 Pin3 N115/230VAC Con1 Pin1 AC Con1 Pin2 DC Common Unit OK Unit OK Con3 - Pin1 Bus Indicator Con2 - Pin1/2 Con2 - Pin3/4 V-Sense +Vout Current Share- line Unit OK Con3 - Pin4 Con3 - Pin3 Con3 - Pin2 -Vout 24/48VDC Specifications Rating per relay contact 60 VDC /0.36 A max. Instruction manual for RED option can be downloaded under: www.tracopower.com/overview/tis
http://www.tracopower.com Page 5 of 12 Power Supplies with Powerfail Functions These models provide 3 functions required in many process control system applications: ◆ AC-Powerfail signal (relay contact) ◆ Power Good signal (relay contact) ◆ Remote On/Off Industrial Power Supplies TIS Series 50–600 Watt Order Code Input Voltage Output Power Output Voltage Output Current (includes terminal plugs) max. nom. max. TIS 150-124 SIG 115/230 VAC 150 W 24 VDC 6.0 A TIS 150-148 SIG selectable 48 VDC 3.0 A TIS 300-124 SIG 115/230 VAC 300 W 24 VDC 12 A TIS 300-148 SIG selectable 48 VDC 6.0 A TIS 600-124 SIG 115/230 VAC 600 W 24 VDC 24 A TIS 600-148 SIG selectable 48 VDC 12 A Models Remote ON/OFF L115/230VAC Con1 Pin1 N Con1 Pin2 Con1 Pin3 AC DC Mains Fail Detection Mains OK Remote ON/OFF +Vout Con2 - Pin3/4 -Vout24/48VDC Common AC-Powerfail Con3 - Pin2 Con3 - Pin7 Con3 - Pin6 Con2 - Pin1/2 Output OK Power Good Detection Power Good Common Power Good Power Good Con3 - Pin5 Con3 - Pin4 Con3 - Pin3 Con3 - Pin1 (Relay A) (Relay B) Specifications Power Good signal trigger point models with 24 Vout: >22.8 VDC ±0.5 V relay B closed (pin 4 – pin 3) models with 48 Vout: >45.6 VDC ±1.0 V relay B closed (pin 4 – pin 3) AC-Powerfail signal Vin <93 resp. <187 VAC relay A closed (pin 7 – pin 6) Raiting per relay contact 60 VDC /0.36 A max. Remote On/Off – On short circuit con 3 pin 1 and pin 2 – Off open circuit con 3 pin 1 and pin 2 Instruction manual for SIG option can be downloaded under: www.tracopower.com/overview/tis
http://www.tracopower.com Page 6 of 12 DC-UPS-System Industrial Power Supplies TIS Series 50–600 Watt In addition to the standard power supply function, these models include a professional battery management system to charge and monitor an external battery. In the event of a power failure the battery is switched automatically and without any interruption to the DC output. Once mains power is available again, the battery is switched off. The backup time is limited only by battery capacity and load. Charge current and voltage can be adjusted to values as required by battery type. Power fail and low battery alarm signals are available via two independent relay contacts. During normal operation the battery status is monitored by periodically loading the battery for a short time. If a cell resistance is high, there is a relay alarm is available. The battery is fully protected under any operational conditions. The power supply is short circuit protected even in battery backup operation but, for safety reasons, the bat - tery should be fitted with a fast blow fuse. Battery mode can be activated by interconnecting pin 7 and 8. External Batteries For external batteries we recommend: Two Panasonic LC-R123R4PG in series for 3.4 Ah: www.tracopower.com/products/tsp-panas_034.pdf Two Panasonic LC-R127R2PG1 in series for 7 .2 Ah: www.tracopower.com/products/tsp-panas_072.pdf Mounting Devices for Batteries Order Code: TIS 24-32AF Frame & wiring for two Panasonic LC-R123R4PG batteries TIS 24-70AF Frame & wiring for two Panasonic LC-R127R2PG1 batteries Order Code 1) Input Voltage Output Power Output Voltage Output Current 2) max. nom. max. TIS 300-124 UDS 115/230 VAC 300 W 24 VDC 12 A selectable TIS 600-124 UDS 115/230 VAC 600 W 24 VDC 24 A selectable Models 1) Includes terminal plugs, does not include batteries 2) reduce max. output current by battery charging current
http://www.tracopower.com Page 7 of 12 DC-UPS-System Industrial Power Supplies TIS Series 50–600 Watt Batter y ON/OFF Con4 Pin7 L115/230VAC Con1 Pin1 Con4 Pin8 N Con1 Pin2 Batter y - Batter y + Con1 Pin3 Con3 - Pin1 Con3 - Pin2 AC DC Mains Fail Detection Battery Test Battery OK Battery Low / failure Common Low Battery Con4 - Pin4 AC-Power fail Con4 - Pin6 Con4 - Pin5 Batter y Switch Logic I Battery ChargerV +VoutCon2 - Pin3/4 -Vout24VDC Common AC-Power OK AC-Powerfail Con4 - Pin3 Con4 - Pin2 Con4 - Pin1 Con2 - Pin1/2 Output OK VBat>18V Bat ON/OFF Mains Fail (Relay B) (Relay A) Specifications Charging current (factory set) TIS 300-124 UDS: 1.2 A TIS 600-124 UDS: 2.4 A Adjustment range of charging current TIS 300-124 UDS: 0.15 – 1.5 A TIS 600-124 UDS: 0.25 – 2.5 A Holding current for charged battery at voltage 27 .3 VDC <50 mA Overload or short circuit during battery operation system switches off AC-Powerfail signal Vin <93 or <187 VAC relay A closed (pin 2 – pin 3) Low battery signal – Battery voltage below 22 V relay B closed (pin 5 – pin 6) – Raiting per relay contact 60 VDC /0.36 A max. During battery charge operation output current reduction by 1.4 x battery charge current Supporting documents : www.tracopower.com/overview/tis
http://www.tracopower.com Page 8 of 12 100.0 (3.94) 75 (2.95) 37.5 (1.48) 74.0 (2.91) 56.7 (2.23) 26 (1.02) (0.2) 31.5 (1.24) (0.39) TIS 50-112 Input 115/230 VAC 1,2/0,7 A NL
12 VDC
3,5 A Output + – Industrial Power Supply Model DC-ON adj 114.6 (4.51) 90 (3.54) 45 (1.77) (0.39) 56.7 (2.23) (0.2) 39.5 (1.56) TIS 75-112 Input 115/230 VAC 1,7/0,9 A NL + – Industrial Power Supply Model DC-ON adj 114.6 (4.51) (0.39) 80 (3.15)38.5 (1.52) (0.2) 39.5 (1.56) TIS 150-124 Input 115/230 50/60Hz 3,7/1,7 A N L
24 VDC / 6 A
+ – Industrial Power Supply Model DC-ON Case Dimensions Industrial Power Supplies TIS Series 50–600 Watt TIS 50 models TIS 75 models Weight: 0.48 kg (1.06 lb) Weight: 0.80 kg (1.76 lb) TIS 150 models Weight: 0.41 kg (0.9 lb) Dimensions in [mm], () = Inch Tolerances: ±0.5 (±0.02) TIS PLUG-1 Connector Set for TIS 50/ 75/ 150 TIS PLUG-1-RED Connector Set for TIS 150-1xx RED Connectors ( Included in shipment)
http://www.tracopower.com Page 9 of 12 114.6 (4.51) (0.39) 83 (3.27) 38.5 (1.52) 130 (5.12) 83 (3.27) 207 (8.15) 91.5 (3.6) (1.36) 34.5 34 (1.34) (0.2) 39.5 (1.56) TIS300-172 Input 115/230 50/60Hz 5,4/3,3 A N L
72 VDC / 4 A
+ – Industrial Power Supply Model DC-ON + – 83 (3.27) 130 (5.12) 220 (8.66) (0.39) (0.2) 5 47 (1.85) TIS 500-124-230 Input
230 VAC 50/60Hz
5,3 A N L
24 VDC / 20 A
+ – Industrial Power Supply Model DC-ON + – Case Dimensions Industrial Power Supplies TIS Series 50–600 Watt TIS 300 models Weight: 1.4 kg (3.09 lb) Weight: 1.9 kg (4.19 lb) TIS 500 models Dimensions in [mm], () = Inch Tolerances: ±0.5 (±0.02) TIS PLUG-3 Connector Set for TIS 300 TIS PLUG-3-RED Connector Set for TIS 300-1xx RED TIS PLUG-3-UDS Connector Set for TIS 300-1xx UDS TIS PLUG-5 Connector Set for TIS 500 Connectors ( Included in shipment)
http://www.tracopower.com Page 10 of 12 6.8 (0.27) (1.26) 120.2 (4.73) 82.6 (3.25) 179 (7.05) 243 (9.57) TIS 600-124 Input 115/230 VAC 50/60Hz 10,5/6,4 A N L Outline Dimensions mm (inches) Industrial Power Supplies TIS Series 50–600 Watt TIS 600 models Weight: 2.0 kg (4.41 lb) Dimensions in [mm], () = Inch Tolerances: ±0.5 (±0.02) TIS PLUG-6-RED Connector Set for TIS 600-1xx RED TIS PLUG-6-UDS Connector Set for TIS 600-1xx UDS Connectors ( Included in shipment)
http://www.tracopower.com Page 11 of 12 Optional Mounting Systems Industrial Power Supplies TIS Series 50–600 Watt Wall mounting kit B A C 7.5 (0.30) D E 4.6 (0.18) Models Order code A B C D E Rugged DIN-Rail mounting kit * included in standard shipping Note * End of life 4.2 (0.17) (0.98) 50.1 (1.97) A B C countersink M4 TIS 150 RMK-150 150 (5.91) 115 (4.53) 35 (1.38) TIS 300 RMK-300 200 (7.87) 165 (6.50) 35 (1.38) TIS 500 RMK-300 200 (7.87) 165 (6.50) 35 (1.38) TIS 600 (standard) * 180 (7.09) 165 (6.50) 15 (0.59) Models Order code A B C Dimensions in [mm], () = Inch Tolerances: ±0.5 (±0.02)
Outline Dimensions mm (inches) Specifications can be changed without notice! Make sure you are using the latest documentation, downloadable at www.tracopower.com www .tracopower.com Industrial Power Supplies TIS Series 50–600 Watt TIS 24-32AF (Frame & wiring, excluding batteries) TIS 24-70AF (Frame & wiring, excluding batteries) A B A B 204 (8.03) 184 (7.24) 69 (2.72) Detail B Detail A (0.35) 5.8 (0.23) (0.47) (0.55) (0.28) 100 (3.94) 135 (5.14) (0.28) B A 272 (10.71) 252 (9.92) B A 100 (3.94) Rev. November 23, 2021 Dimensions in [mm], () = Inch Tolerances: ±0.5 (±0.02)