PUMA68FV16006X-70 MOSAIC | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 5

Technical content

Features

 Access times of 70, 90 and 120ns.  3.3V + 10%.  Commercial and Industrial temperature grades  JEDEC Standard 68 PLCC footprint.  Industry standard pinout.  May be organised as 512Kx32, 1Mx16 or 2Mx8  User configurable as 8 / 16 / 32 bits wide.  10 Year Data Retention  Write Erase Cycle Endurance 100,000 (min)  Automatic Write/Erase by Embedded Algorithm  Uniform Sector Device. PUMA68FV16006X - 70/90/12 Issue 5.0 April 2001

Description

The PUMA68 range of devices provide a high density surface mount industry standard memory solution which may accommodate various memory technologies including SRAM, EEPROM and Flash. The devices are designed to offer a defined upgrade path and may be user configured as 8, 16 or 32 bits wide. The PUMA68FV16006X is a 512Kx32 FLASH mod- ule housed in a 68 Jleaded package which complies with the JEDEC 68 PLCC standard. Access times of 70, 90 or 120ns are available. The 3.3V device is available to commercial and industrial temperature grade. 1M x 32, and 2Mx32 FLASH PUMA68 devices are available in the same footprint to offer a defined upgrade path.

Issue 5.0 April 2001PAGE 2 Pin Definition - PUMA68F16006X Pin Signal Pin Signal

1 V CC 35 V CC

2 NC 36 A13

7 A17 41 A8

8 A18 42 A7

9 D16 43 D0

10 D17 44 D1

11 D18 45 D2

12 D19 46 D3

13 V SS 47 V SS

14 D20 48 D4

15 D21 49 D5

16 D22 50 D6

17 D23 51 D7

18 V CC 52 V CC

19 D24 53 D8

20 D25 54 D9

21 D26 55 D10

22 D27 56 D11

23 V SS 57 V SS

24 D28 58 D12

25 D29 59 D13

26 D30 60 D14

27 D31 61 D15

28 A6 62 A14

29 A5 63 A15

30 A4 64 A16

31 A3 65 /WE

32 A2 66 /OE

33 A1 67 NC

34 A0 68 NC

PAGE 3 Issue 5.0 April 2001 PUMA 68 pin JEDEC Surface Mounted PLCC 25.02 (0.985) 0.90 (0.035) typ 23.11 (0.910) 5.08 (0.200) max 24.13 (0.950) 25.27 (0.995) 1.27 (0.050) 0.46 (0.018) Pin 68Pin 1

Ordering Information

PAGE 4 Issue 5.0 April 2001 /G50/G55/G4D/G41/G20/G36/G38/G46._/G56/G31/G36/G30/G30/G36/G58/G49/G20/G2D/G20/G37/G30 Speed 70 = 70ns 90 = 90ns 12 = 120ns Temp. Range/Screening Blank =Commercial I = Industrial Pinout Configuration X = Industry Standard Pinout Memory Organisation 16006 = configurable as 512K x 32, 1M x 16 or 2M x 8 Technology FV = FLASH (3.3V) Package PUMA 68 = 68 pin ‘J’ Leaded PLCC http://www.mosaicsemi.com/ Note : Although this data is believed to be accurate the information contained herein is not intended to and does not create any warranty of merchantibility or fitness for a particular purpose. Our products are subject to a constant process of development. Data may be changed without notice. Products are not authorised for use as critical components in life support devices without the express written approval of a company director.

PAGE 5 Issue 5.0 April 2001 Visual Inspection Standard All devices inspected to ANSI/J-STD-001B Class 2 standard Moisture Sensitivity Devices are moisture sensitive. Shelf Life in Sealed Bag 12 months at <40O C and <90% relative humidity (RH). After this bag has been opened, devices that will be subjected to infrared reflow, vapour phase reflow, or equivalent processing (peak package body temp 220O C) must be : A : Mounted within 72 Hours at factory conditions of <30O C/60% RH OR B : Stored at <20% RH If these conditions are not met or indicator card is >20% when read at 23 O C +/-5% devices require baking as specified below. If baking is required, devices may be baked for :- A : 24 hours at 125O C +/-5% for high temperature device containers OR B : 192 hours at 40 O C +5O C/-0O C and <5% RH for low temperature device containers. Packaging Standard Devices packaged in dry nitrogen, JED-STD-020. Packaged in trays as standard. Tape and reel available for shipment quantities exceeding 200pcs upon request. Soldering Recomendations IR/Convection - Ramp Rate 6 O C/sec max. Temp. exceeding 183O C 150 secs. max. Peak Temperature 225 O C Time within 5O C of peak 20 secs max. Ramp down 6 O C/sec max. Vapour Phase - Ramp up rate 6 O C/sec max. Peak Temperature 215 - 219 O C Time within 5O C of peak 60 secs max. Ramp down 6 O C/sec max. The above conditions must not be exceeded. Note : The above recommendations are based on standard industry practice. Failure to comply with the above recommendations invalidates product warranty.