Rev. 07.08.13 PSE1000PFC 1 of 4 Embedded Power for Business-Critical Continuity Electrical Specifications Input Input ra nge: 90 - 264 Vac (Operating) 115/230 Vac (Nominal) Frequency: 47 - 63 Hz Inrush current: ≤ 50 A peak at 230 Vac @ 25 deg C (with external resistor from INRUSH pin to OUTPUT -) Power factor: > 0.97 typical Input current: 10.3 A RMS max input current, at 115 Vac Hold up time: 16 ms minimum, at 115 Vrms AC input, full load with 680 uF/450 Vdc electrolytic capacitor Efficiency: > 94% typical at full load / 230 VAC nominal ON/OFF power switch Remote negative enable Isolation: PRI-Chassis 1500 Vac PSE1000-PFC

1000 Watts

  • 1000 W output power
  • Unity power factor correction
  • 3.5” x 2.4” x 1”
  • 119 Watts per cubic inch
  • Industrial safety
  • -40 °C to 85 °C
  • High efficiency: 94% typical
  • Negative enable function
  • Output OTP, OVP and power limit
  • Current sharing and monitoring
  • MIL-STD-810F for shock and vibration Total Power: 1000 W # of Outputs: Single Output: 390 V Safety
  • UL 60950-1 508/1598/1433 60601-1 EO 3
  • cUL 60950-1
  • TUV 60950-1 60601
  • CB Scheme Report/Cert Compliance
  • EMI Class B (with external filter)
  • EN61000 lunity
  • RoHS 2

Rev. 07.08.13 PSE1000PFC 2 of 4 Embedded Power for Business-Critical Continuity Output Output rating 390 Vdc 180 - 264 Vac Set point Total regulation range 380 V to 400 Vdc

5 Vsb ± 1%

With 680 uF / 450 V electrolytic capacitor Rated load 1000 W maximum No derating up to 85 °C, Vin > 100 Vac Minimum load Main output @ 0.0 A No loss of regulation Output noise (PARD) < 50 V max p-p Full load at 680 uF / 450 V capacitor Output voltage overshoot No overshoot/undershoot outside the regulation band during ON or OFF cycle Transient response < 300 µSec 50% load step @ 1 A/µs Step load valid between 10% to 100% of output rating Recovery time to within 1% of set point at onset of transient Max units in parallel Up to 10 Remote sense Compensation up to 500 mV Output isolation Standard per safety requirements Forced load sharing To within 10% of all shared outputs Analog sharing control Overload protection (OCP) 140% to 160% Overvoltage protection (OVP) 110% to 135% Latched until AC line recycle Overtemp protection 102 - 107 °C baseplate temperature Shut down and automatically restart when fault is removed Environmental Specifications Electrical Specifications Operating temperature: -40 °C to +85 °C baseplate temperature Storage temperature -40 °C to +100 °C Humidity 10 to 100% non-condensing operating Altitude Operating - 13,000 feet, derating 1 degree C per 1000 feet above 10,000 feet Storage - 50,000 feet Shock MIL-STD-810F 516.5, Vibration MIL-STD-810F 514.5, Cat, IEC68-2-6 Model Number Output Nominal Output Voltage Set Point Current Output Ripple P/P 0-50 deg C Max Continuous Power Combined Line/ Load RegulationMin Max PSE1000PFC 390 V 390 V 0 A 2.82 A < 50 V 1000 2.5%

Ordering Information

C. Mon Current monitoring TXD Digital communication LD EN Load Enable Relay C. Share Current Share RXD Digital communication Remote Remote ON/OFF INRUSH Limit Inrush Current Output + DC Output + Output - DC Output - Mechanical Drawing Rev. 07.08.13 PSE1000PFC 3 of 4 Embedded Power for Business-Critical Continuity

Rev. 07.08.13 PSE1000PFC 4 of 4 Embedded Power for Business-Critical Continuity Americas

5810 Van Allen Way

Carlsbad, CA 92008 USA Telephone: +1 760 930 4600 Facsimile: +1 760 930 0698 Europe (UK) Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX United Kingdom Telephone: +44 (0) 1384 842 211 Facsimile: +44 (0) 1384 843 355 Asia (HK) 14/F, Lu Plaza

2 Wing Yip Street

Kwun Tong, Kowloon Hong Kong Telephone: +852 2176 3333 Facsimile: +852 2176 3888 For global contact, visit: www.Emerson.com/EmbeddedPower techsupport.embeddedpower @emerson.com While every precaution has been taken to ensure accuracy and completeness in this literature, Emerson Network Power assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. Emerson and the Emerson Network Power logo are trademarks of Emerson Electric Co. ©2013 Emerson Electric Co. All rights reserved. EmersonNetworkPower.com Embedded Computing Embedded Power Monitoring Outside Plant Power Switching & Controls Precision Cooling Racks & Integrated Cabinets Services Surge Protection Emerson Network Power. The global leader in enabling business-critical continuity. AC Power Connectivity DC Power Burn-In 100% Burn-in at 45 °C, at 80 - 90% load. Duration of burn-in determined by Quality Assurance Procedures MTBF The power supply has a minimum MTBF of 300K hours using the Bell core 332, issue 6 specification @ 25 °C and 40 °C, ambient, at full load. With the power supply installed in a system in a 25 °C ambient environment and operating at full load, capacitor life shall be 10 years, minimum for ALL electrolytic capacitors contained within this power supply. The power supply shall demonstrate a MTBF level of > 500,000 hours. Quality Assurance Full QAV testing shall be conducted in accordance with Emerson Network Power Standards with reports available upon request. Warranty Emerson Network Power shall warrant the power supply to be free of defects in materials and workmanship for a minimum period of three years from the date of shipment, when operated within specifications. The warranty shall be fully transferable to the end owner of the equipment powered by the supply. Miscellaneous Specifications