PS69-DPM PROSOFT | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 3
Technical content
The PS69 PROFIBUS DP Master module expands the functionality of ’s CompactLogix / MicroLogix family of processors to include PROFIBUS. This module supports both I/O control and messaging, thus integrating DPV0 and DPV1 functionality into CompactLogix / MicroLogix. The PS69-DPM is a CompactLogix / MicroLogix compatible, PROFIBUS certified module, which enables controllers to communicate with a PROFIBUS network. The configuration and diagnostic of the PROFIBUS system is done via the serial diagnostic interface of the module using the System Configuration tool . The data exchange between controller and module is done via the I/O process data image using CompactLogix / MicroLogix backplane technology. DPV0 Services Supported Fail Safe Mode Global Control Sync and Freeze Watchdog DPV1 Services Supported Read Request Write Request Alarm Indication Extended Device Diagnostics Features Benefits PROFIBUS certified Recognized quality certification mark FDT configuration software and communication DTM included Module DTM will configure master module and network slave devices. The DTM can be used in many FDT compatible software containers Sample ladder program Simplifies integration for quick and easy project start-up Supports CIP ladder logic messaging Request diagnostic, status and slave data based on ladder events. Offer better cyclic data performance Configuration The Configuration for the PS69-DPM is done with our next generation configuration tool PROSOFT.fdt. The configuration software and communication DTM are included with the module allowing easy configuration of the Master module and network slave devices. The DTM can be used in any FDT compatible software container. The configuration is transferred via the serial diagnostic interface and stored in the FLASH memory of the PS69-DPM module.
Input/Output Maximum 244 Bytes per Slave Input Data Maximum 408 Bytes (*) Acyclic Data DPV1 Status data 88 Bytes Output data Maximum 480 Bytes (*) Command data 16 Bytes DPV1 services Read / Write class 1, Alarm Services Global-Control, Slave-Diag, Set-Parameter Sync, Freeze Command Supported Up to 32 PROFIBUS devices can be connected to one bus segment. If several bus segments are linked to each other with repeaters, there can be up to 127 devices on the network. The maximum length of a bus segment depends on the baud rate used. Only PROFIBUS certified cable, preferably the cable type A, should be used. Baud rate in kBit/s Max. Distance 9.6 1,200 m / 4000 ft 19.2 1,200 m / 4000 ft 93.75 1,200 m / 4000 ft 187.5 1,000 m / 3280 ft 500 400 m / 1300 ft 1,500 200 m / 650 ft 3,000 100 m / 325 ft 6,000 100 m / 325 ft 12,000 100 m / 325 ft Parameter Value Impedance 135 to 65 Ohm Capacity < 30 pF/m Loop resistance 110 Ohm/km Wire gauge 0.64 mm Where Automation Connects™ Global Distribution We think like you do ProSoft Technology® products are distributed and supported worldwide through a network of over 500 distributors in over 50 countries. Our knowledgeable distributors are familiar with your application needs. For a complete list of distributors, go to our web site at: www.prosoft-technology.com Global Support We are there for you All ProSoft Technology products are backed with free, unlimited technical support. Contact our worldwide Technical Support team directly by phone or email. Global Offices We are where you are ProSoft Technology has regional offices worldwide available to help you with all your industrial application needs. If you need help choosing a ProSoft Technology solution for your particular application check out our contact information under distributor sales on the web site at: www.prosoft-technology.com Whether your application is large or small, our technical professionals are there to help you choose the right communication solution.
Single Slot – 1769 backplane compatible The module is recognized as an Input/Output module and has access to processor memory for data transfer between processor and module Ladder Logic is used for data transfer between module and processor. Sample ladder file included. Supports all CompactLogix and MicroLogix 1500 LRP Controllers except 1769- L23E-QBFC1B, 1769-L16x, and 1769-L18x Hardware Specifications Specification Description Processor EC1-160P with integrated ASPC2 PROFIBUS Interface RS-485, max. 12 MBaud, potential free, according EN 50170 Diagnostic Interface RS232, PS/2 Mini DIN female connector, 9600 Baud, non isolated Power Supply +5 V ±5 % / 260 mA Max. Distance Rating Maximum 6 modules to the power supply module Dimensions Standard 1769 Single-slot module Burst EN 61000-4-4, 2 kV, 5 kHz Surge EN 61000-4-5, 2 kV common mode, 1 kV differential mode ESD EN 61000-4-2, 4 kV contact, 8 kV air, 4 kV indirect Radiated/ Conducted Immunity EN 61000-4-3, 10 V/m, 30...1000 MHz, 80% AM, 1 kHz sinewave EN 61000-4-6, 10 V, 0,15...30 MHz Radiated/ Conducted Emission EN 55011 Class A Vibration/Shock IEC 600068-2-6, 10-150 Hz, ± 0,75 mm, ± 1 g, 1 Octave/min IEC 600068-2-27, 15 g, 11 ms Operating Temp. 0°C to 60°C (32°F to 140°F) Relative Humidity 5 to 95% (non-condensing) Agency Certification: UL/CE C-UL certified, UL 508 listed, CE PROFIBUS conformance Certified Additional Products ProSoft Technology® offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. For a complete list of products, visit our web site at: www.prosoft-technology.com
Ordering Information
To order this product, please use the following: PROFIBUS DPV1 Master Communication Module PS69-DPM To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft Technology distributors near you, go to: www.prosoft-technology.com and select Where to Buy from the menu. Copyright © 2014 ProSoft Technology, Inc. All rights reserved. 10/1/2014 Specifications subject to change without notice.