Features
AOI: Module communication is integrated within Studio/RSLogix 5000 using a sample Add-On Instruction (AOI), or sample ladder logic file, reducing commissioning time. Autoscan: The new Autoscan feature reduces start up times and simplifies troubleshooting by scanning the PROFIBUS network and uploading slave device addresses and configuration information. (Reads and maps nodes automatically to the module.) ComDTM: Allows remote Ethernet connectivity with Asset Management Software significantly lowering maintenance costs. You can configure, commission, maintain and diagnose your fieldbus devices throughout their entire lifecycle with this comprehensive, fully integrated engineering and maintenance environment. SD card slot (SD card optional) is used for storing configuration files in the event of a disaster. It can also be used to update the firmware of the module without the need of a 1769 CPU.
PROFIBUS DP Specifications Specification Description Slaves Maximum 125 Input/Output Maximum 244 Bytes per Slave Input Data Maximum 5712 Bytes Acyclic Data DPV1 Status data 88 Bytes Output data Maximum 5760 Bytes DPV1 Services Class 1 Read/Write Class 1 Alarm Class 2 Initiate/Read/Write/Data transport/Abort Services Global-Control, Slave-Diagnostic, Set-Parameter Sync, Freeze Command Supported Baud rate 9.6 kBaud, 19.2 kBaud, 45.45 kBaud, 93.75 kBaud, 187.5 kBaud, 500 kBaud 1.5 MBaud, 3 MBaud, 6 MBaud, 12 MBaud Auto-detection mode is supported Hardware Specifications Specification Description PROFIBUS Interface RS-485, max. 12 Mbps, potential free, according EN 50170 Diagnostic Interface 10/100 Ethernet, RJ45 Power Supply +5 V ±5 % / 570 mA Max. Distance Rating 2 slots Dimensions Standard 1769 Single-slot module Burst EN 61000-4-4, 2 kV, 5 kHz Surge EN 61000-4-5, 2 kV common mode, 1 kV differential mode ESD EN 61000-4-2, 4 kV contact, 8 kV air, 4 kV indirect Radiated/Conducted Immunity EN 61000-4-3, 10 V/m, 30...1000 MHz, 80% AM, 1 kHz sine wave EN 61000-4-6, 10 V, 0,15...30 MHz Radiated/Conducted Emission EN 55011 Class A Vibration/Shock IEC 600068-2-6, 10-150 Hz, ± 0,75 mm, ± 1 g, 1 Octave/min IEC 600068-2-27, 15 g, 11 ms Operating Temperature 0°C to 60°C (32°F to 140°F) Relative Humidity 5 to 95% (non-condensing) PROFIBUS conformance Certified Agency Approvals and Certifications PROFIBUS PI Certified (pending) CE Mark UL/cUL Class 1 Div 2 ATEX Zone 2 CB Safety Where Automation Connects™ Global Distribution ProSoft Technology® products are distributed and supported worldwide through a network of over 500 distributors in over 50 countries. Our knowledgeable distributors are familiar with your application needs. For a complete list of distributors, go to: www.prosoft-technology.com
Ordering Information
To order this product, please use the following: PROFIBUS Master Network Interface Module for CompactLogix ILX69-PBM To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft Technology distributors near you, go to: www.prosoft-technology.com and select Where to Buy from the menu. Copyright © 2017 ProSoft Technology, Inc. All Rights Reserved. 3/13/2017 Specifications subject to change without notice.