DATASHEET SEARCH SITE | WWW.ALLDATASHEET.COM
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 2
Technical content
Features
AOP and AOI: Module communication is integrated within Studio/RSLogix™ 5000 using a sample Add-On Instruction (AOI), and custom configuration utility created Add-On Routines to reduce commissioning time. Autoscan: The Autoscan feature reduces startup times and simplifies troubleshooting by scanning the PROFIBUS network and uploading slave device addresses and configuration information. (Reads and maps nodes automatically to the module.) ComDTM: Allows remote Ethernet connectivity with Asset Management Software, significantly lowering maintenance costs. You can configure, commission, maintain and diagnose your fieldbus devices throughout their entire lifecycle with this comprehensive, fully integrated engineering and maintenance environment. SD card slot (SD card optional) is used for storing configuration files in the event of a disaster.
PROFIBUS DP Master Specifications Specification Description Slaves Maximum 125 Input/Output Maximum 244 Bytes per Slave Input Data Maximum 5000 Bytes Acyclic Data DPV1 Status data 88 Bytes Output data Maximum 5000 Bytes DPV1 Services Class 1 Read/Write Class 1 Alarm Class 2 Initiate/Read/Write/Abort Services Global-Control, Slave-Diagnostic, Set-Parameter Sync, Freeze Command Supported kBaud, 500 kBaud 1.5 MBaud, 3 MBaud, 6 MBaud, 12 MBaud PROFIBUS DP Slave Specifications Specification Description Slaves Emulate up to 10 slaves Input/Output Maximum 244 Bytes per Slave Input Data Maximum 2440 Bytes Acyclic Data DPV1 Status data 88 Bytes Output data Maximum 2440 Bytes DPV1 Services Class 1 Read/Write, Class 1 Alarm Services Global-Control, Slave-Diagnostic, Set-Parameter Sync, Freeze Command Supported kBaud, 500 kBaud 1.5 MBaud, 3 MBaud, 6 MBaud, 12 MBaud. Auto-detection mode is supported Hardware Specifications Specification Description PROFIBUS Interface RS-485, Max. 12 Mbps, potential free, according EN 50170 Power Supply 450 mA @ 5Vdc, 2 mA @ 24 Vdc Dimensions Standard 1756 Single-slot module Burst EN 61000-4-4, 2 kV, 5 kHz Surge EN 61000-4-5, 2 kV common mode, 1 kV differential mode ESD EN 61000-4-2, 4 kV contact, 8 kV air, 4 kV indirect Radiated/Conducted Immunity EN 61000-4-3, 10 V/m, 30...1000 MHz, 80% AM, 1 kHz sine wave EN 61000-4-6, 10 V, 0,15...80 MHz Radiated/Conducted Emission EN 55011 Class A Vibration/Shock (operating) IEC 600068-2-6, 10-500 Hz, ± 0,75 mm, ± 2 g, 1 Octave/min IEC 600068-2-27, 30 g, 11 ms Operating Temperature 0°C to 60°C (32°F to 140°F) Relative Humidity 5 to 95% (non-condensing) PROFIBUS Conformance Certified (pending) Agency Approvals & Certifications Please visit our website: www.prosoft-technology.com Where Automation Connects™ Global Distribution ProSoft Technology® products are distributed and supported worldwide through a network of over 500 distributors in over 50 countries. Our knowledgeable distributors are familiar with your application needs. For a complete list of distributors, go to: www.prosoft-technology.com
Ordering Information
To order this product, please use the following: PROFIBUS Master/Slave Network Interface Module for ControlLogix ILX56-PBM To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft Technology distributors near you, go to: www.prosoft-technology.com and select Where to Buy from the menu. Copyright © 2020 ProSoft Technology, Inc. All Rights Reserved. 3/26/2020 Specifications subject to change without notice.