DATASHEET SEARCH SITE | WWW.ALLDATASHEET.COM

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 4

Technical content

˙MODEL NUMBER DESIGNATION P S 6 0 - 1 0 2 R - N M C N Series name Signal / power cable pullout method Pressure port Switch output interface Rated pressure range Pressure reference 102ɿ−100 ~ 100 kPa 103 ɿ−100 ~ 1000 kPa 302ɿ−100 ~ 300 kPa RɿCompound pressure (Negative pressure ~ Positive pressure) CNɿConnector pullout MɿM5 female screw NɿNPN open collector PɿPNP open collector PRESSURE SWITCHES WITH GAUGE PS60 Part name Material Pressure port “O” ring Sensor module board Housing Display board Operation panel seet Polyamide (Resin of MXD6 series) Brass (Ni-plated) Fluoro-rubber ——— PBT (Polybutyleneterephtalate) ——— Polyester INTERNAL STRUCTURE /g79/g3Applicable for negative through positive pressure with 10 mm thick slim housing /g79/g3Suitable for use in clean rooms with easy-to-use push keys /g79/g3Plug-in connector is provided for easy installation and maintenance /g79/g3Space saving and mountable on DIN rails /g79/g3Data protection by panel lock system /g79/g3Low consumption by nondisplay mode ˙FEATURES ˙ LIST OF MODEL NUMBERS Pressure port M 5 female screw NPN open collector output PNP open collector output Switch output 102R 302R 103R −100 ~ 100 kPa −100 ~ 300 kPa −100 ~ 1000 kPa PS60-102R-NMCN PS60-302R-NMCN PS60-103R-NMCN PS60-102R-PMCN PS60-302R-PMCN PS60-103R-PMCN ˞Verify the above model numbers when placing orders. marking Compatible with EMC directive 1 2 3 4

PRESSURE SWITCHES WITH GAUGE General specificationsDisplay Power Item Model number 102R 302R 103R PS60 ˙STANDARD SPECIFICATIONS Pressure reference Gauge Non-corrosive gases −100 ~ 100 −100 ~ 300 −100 ~ 1000 200 600 1500 500 1000 2000 −10 ~ 50 0 ~ 50 35 ~ 85ʢNo condensationʣ −20 ~ 70ʢAtmospheric pressure, humidity 65 %RH maximumʣ Approx. ʢIncludihg cableʣ 12 ~ 24 V ± 10 %ʢIncluding ripple percentageʣ 100 (500 V DC)

500 V AC, 60 sʢLeakage current 1 mA maximumʣ

−100 ~ 100 kPa −100 ~ 300 kPa −0.10 ~ 1.00 MPa ± 1 %F.S. 1 count Pressure medium Rated pressure range kPa Maximum pressure kPa Break-down pressure kPa Operating temp. range °C Compensated temp. range °C Operating humidity %RH Storage temp. °C Net weight g Supply voltage V DC Consumption current mA max. Insulation resistance M Ω min. Thermal error Dielectric strength Pressure port Display element Rated display range Display accuracy ʙ ˆ ʢReference temp. 25 °Cʣ Resolution /g79/g3Unless otherwise specified, the specs are defined at an ambient temperature of 25 ± 5 °C and excitation voltage of 24 V DC. Switch output 0 ~ 30 counts

30 V 100 mA maximum

1.2 (NPN), 2.2 (PNP) −110 kPa (approx.) ~ “999” counts Red LED ON ± 0.3 %F.S. maximum Approx. 5, 25, 250 PS60 cable, DIN rail adaptor Adjustable range Switching capacity Residual voltage V maximum Display Repeatability Switch hysteresis Response ms Accessories Open collector output (NPN or PNP) Adjustable by panel switch 2No. of outputs Output interface Setting method

PRESSURE SWITCHES WITH GAUGE ˙ CIRCUIT DIAGRAMS Pressure Load S.Output1Main circuit Power B Sensor Common S.Output2 Load 2 ̡̙̚ɹIndicator1 LED Pressure indication Sensor Main circuitPressure Power B S.Output2 1 ̡̙̚ɹIndicator2 Pressure indication LED Common S.Output1 Load Load /g79/g3NPN open collector /g79/g3PNP open collector ˙ SWITCH OUTPUT MODE ˙ DISPLAY RANGE 0VUQVU .PEF 0QFSBUJPO Pressure setting (Operating point) 4FUUJOH 4FUUJOH -PXFSMJNJU 4FUUJOH 6QQFSMJNJU 4FUUJOH -PXFSMJNJU 4FUUJOH 6QQFSMJNJU 4FUUJOH 48 48 Separate mode Window comparator mode 4FQBSBUF 8JOEPXDPNQBSBUPS 4FQBSBUF 8JOEPXDPNQBSBUPS ʢHI operationʣ ʢ LO operationʣ ʢA operationʣ ʢ B operationʣ P1: SW1 P2: SW2 P1 P2 P1 P2 OFF ON ON ON ON -Pr OFF OFF OFF Pr -Pr Pr -Pr Pr HH P1: SW1 P2: SW2 OFF ON -Pr Pr HH HH HH )ɿSwitch hysteresisɺ 1ʹSetting 1 ɺ1ʹSetting 2 P1ʽP2 or P1ʾP2 P1 ʽP2–2H Note 1. In the Separate Mode, setting 1 corresponds to SW1, and Setting 2 corresponds to SW2. Note 2. In the Window Comparator Mode, the minimum value for SW1 and SW2 corresponds to Setting 1 and the maximum value corresponds to Setting 2. ˞Atmospheric pressure /g79/g3Display range can be selected as the table. Note) “–” on the table indicates that it is not selectable in relation to resolution and display lines. ˞ : In terms of setting display range, please verify the default mode. ˙ ENVIRONMENTAL CHARACTERISTICS Test item Test conditions Permissible change Vibration 10 ~ 500 Hz, 1.5 mm maximum/98.1 m/s 2, 3 directions for 2 hours each 490 m/s2, 3 directions for 3 times each 40 °C, 90 ~ 95 %RH, 240 hrs. 0 ~ Rated pressure, 106 cycles EMI : EN55011: 2007, A2 : 2007 Group 1, class B/g253 EMS : EN61326-1 : 2006 Table 2 Pressure indication and switch operating output : ± 2 %F .S., maximum each after test Pressure indication and switch operating output, alalog output : ± 5 %F .S., maximum during test Shock Moisture resistance Pressure cycling EMC Number 1 (kPa) 2 (MPa) Rated pressure range 102R — — –0.10 ~ 1.00 302R 103R

Length : 1500 50 Heat shrink tube (Black) 4-core cable AWG26 ULNo.2844 ( 4)φ Housing : Manufactured by JST (XAP-04V-1) Contact : Manufactured by JST (SXA-001T-P0.6L) 70 20 50 10 (5) ˙OUTLINE DIMENTIONS Unless otherwise specified, tolerance : ± 0.5 (Unit: mm) PS60 PRESSURE SWITCHES WITH GAUGE Pressure port (PA MXD6) 4.6 Mounting hole Part No. (Laser marking) DIN rail adapter (accessory) Connector : Pitch / 4 poles Housing : Manufactured by JST (XAP-04V-1) < Terminal No. > Housing (PBT) Panel seet (Polyester) 4.5 2 – 3.1 (52.5) 10.2 4.5(7)13.2 1.1 φ –0.225 –0.2 Pressure port (BSBM, Ni-plated) Insert screw : M5 depth 5 /g79/g3Pressure port M type (NMCN, PMCN) Terminal no. Connection SW output 1 SW output 2 Power (DC10.8 ~ 26.4 V) Common Pin no. Wire color Connection Black SW output 1 White SW output 2 Blown Power B Blue Common ˙Accessories /g79/g3DIN rail adapter /g79/g3Connector cable 6.5 PS60 1.1 3.7 1.5 54.2 DIN rail (width 35) adaptaion Tolerated stroke 2 maximuum DIN base : PBT Slide (DIN stopper) : POM