DATASHEET SEARCH SITE | WWW.ALLDATASHEET.COM
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 7
Technical content
Features
Cured, flame retardant epoxy polymer insulating material meets UL 94V-0 requirements RoHS compliant* and halogen free** Agency recognition:
Applications
Almost anywhere there is a low voltage power supply and a load to be protected, including: Computers & peripherals General electronics Automotive applications ***Tested at 40 amps Maximum Device Surface Temperature Condition A Environmental Characteristics Test Test Conditions Accept/Reject Criteria Test Procedures And Requirements For Model PRCP-R Series TNAILPMOC SHoR* CCC ** UL/TÜV only COPAL follows the prevailing definition of “halogen free” in the industy. COPAL considers a product to be “halogen free” if (a) the Bromine (Br) content is 900 ppm or less; (b) the Chlorine (Cl) content is 900 ppm or less; and (c) the total Bromine (Br) and Chlorine (Cl) content is 1500 ppm or less.
Specifications are subject to change without notice. The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time. Customers should verify actual device performance in their specific applications. Product Dimensions (see next page for outline drawing) Packaging options: BULK: All models = 500 pcs. per bag. 0.51 (24AWG) 0.81 (20AWG) PRCP-R Series - Polymer Resettable Circuit Protectors Additional Features Bulk packaging, tape and reel available on most models MM (INCHES)DIMENSIONS = TAPE & REEL: PRCP-R005-PRCP-R160 - 12.7 mm device pitch = 3000 pcs. per reel;
Specifications are subject to change without notice. The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time. Customers should verify actual device performance in their specific applications. Thermal Derating Chart - Ihold / Itrip (Amps) Ambient Operating TemperatureModel -40 ˚C -20 ˚C 0 ˚C 23 ˚C 40 ˚C 50 ˚C 60 ˚C 70 ˚C 85 ˚C 1.53 / 3.06 1.30 / 2.60 NOTE: Kinked lead option is available for board standoff. Contact factory for details. NOTE: Also available with straight leads. Contact factory for details. A E B D B D C Style 1 A E B D C Style 2 A E C Style 3 Style 4 A E B D C Product Dimensions (see previous page for dimensions) PRCP-R Series - Polymer Resettable Circuit Protectors 0.07 / 0.14 1.53 / 3.06
Specifications are subject to change without notice. The device characteristics and parameters inthis data sheet can and do vary in different applications and actual device performance may vary over time. Customers should verify actual device performance in their specific applications. How to Order PRCP - R 110 - 0 - 99 Product Designator Series R = Radial Leaded Component Hold Current, Ihold 005-1100 (0.05 Amps - 11.0 Amps) Packaging Options - 0 = Bulk packaging - 2 = Tape and Reel Part Number Suffix Option - 99 = = Part number suffix option for customers requiring a new part number to reference the engineering change to RoHS compliance. Typical Time to Trip at 23 ˚C 100 0.1 0.01 0.001 0.1 1 10 100 Fault Current (Amps) )sdnoceS( pirt ot emiT PRCP-R017 PRCP-R040PRCP-R075PRCP-R020 PRCP-R050PRCP-R065PRCP-R090PRCP-R025PRCP-R030PRCP-R010PRCP-R005 PRCP-R Series - Polymer Resettable Circuit Protectors 100 0.1 0.01 0.001 1 10 100 Fault Current (Amps) )sdnoceS( pirt ot emiT PRCP-R110 PRCP-R250, 01-0-052 PRCP-R500PRCP-R135 PRCP-R300PRCP-R400PRCP-R600PRCP-R700PRCP-R800PRCP-R900PRCP-R1100PRCP-R160PRCP-R185PRCP-R090 9-0- Typical Part Marking:PRCP-R005-R025 Represents total content. Layout may vary. PART IDENTIFICATION MANUFACTURER'S MARK DATE CODE: WEEK 1 OF 2005 = 5A (YEAR & WEEK) WEEK 27 OF 2005 = A5 (WEEK & YEAR) Typical Part Marking:PRCP-R030-R1100 Represents total content. Layout may vary. MANUFACTURER'S MARKPART IDENTIFICATION DATE CODE (FIRST DIGIT = LAST DIGIT OF YEAR; NEXT THREE DIGITS = DAY OF YEAR) LOT NO. (S = CHINA) c c
Specifications are subject to change without notice. The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time. Customers should verify actual device performance in their specific applications. Devices taped using EIA468–B/IEC286-2 standards. See table below and Figures 1 and 2 for details. IEC EIA Dimensions Dimension Description Mark Mark Dimensions Tolerance Carrier tape width W W Hold down tape width: W0 W4 min. Hold down tape No protrusion Top distance between tape edges W2 W6 max. Sprocket hole position W1 W5 Sprocket hole diameter D0 D0 Abscissa to plane (straight lead) H H Abscissa to plane (kinked lead) H0 H0 Abscissa to top (straight lead) H1 H1 max. Abscissa to top (kinked lead) H1 H1 max. Overall width w/lead protrusion (straight lead) C1 max. Overall width w/lead protrusion (kinked lead) C1 max. Overall width w/o lead protrusion (straight lead) C2 max. Overall width w/o lead protrusion (kinked lead) C2 max. Lead protrusion I 1 L 1 max. Protrusion of cutout L L max. Protrusion beyond hold-down tape I 2 I 2 Not specified Sprocket hole pitch P0 P0 Pitch tolerance 20 consecutive Device pitch: PRCP-R005-PRCP-R160 Device pitch: PRCP-R185‒PRCP-R400 Tape thickness t t max. Tape thickness with splice: PRCP-R010‒PRCP-R160 t 1 max. Tape thickness with splice: PRCP-R250‒PRCP-R1100 t 1 max. Splice sprocket hole alignment 0 Body lateral deviation ∆h ∆h 0 Body tape plane deviation ∆p ∆p 0 (.709) -0.5/+1.0 (-0.02/+.039) (.354) -0.5/+0.75 (-0.02/+0.03) (.157) ±0.2 (±.0078) 18.5 (.728) ±3.0 (±.118) (.63) 32.2 (1.268) 38.0 (1.496) 43.2 (1.7) 55.0 (2.165) 42.5 (1.673) 54.0 (2.126) 1.0 (.039) (.433) ±0.5 (±.02) 12.7 (0.5) 12.7 (0.5) 25.4 (1.0) 0.9 (.035) 1.5 (.059) 2.3 (.091) ±0.3 (±.012) (±.039) ±0.3 (±.012) ±0.6 (±.024) ±0.3 (±.012) ±1.0 (±.039) ±1.3 (±.051) (.433) (.118) DIMENSIONS = MM (INCHES) PRCP-R Series Tape and Reel Specifications
Specifications are subject to change without notice. The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time. Customers should verify actual device performance in their specific applications. t User direction of feed Cross section A - B p p H Reference plane W A B F D0P0I1 L hh h w h f d Reel Upper side Tape Lower side User direction of feed Reel Dimensions - Figure 2 Taped Component Dimensions - Figure 1 DIMENSIONS = MM (INCHES) IEC EIA Dimensions Dimension Description Mark Mark Dimensions Tolerance Arbor hole diameter f c Core diameter h n max. Box nom. Consecutive missing places 3 max. Empty places per reel Not specified (1.024) (3.15) (2.44) 355 (14.0) 345 (13.6) ±12.0 (±.472) PRCP-R Series Tape and Reel Specifications Lead spacing F F Reel width w W2 max. Reel diameter d a max. Space between flanges less device W1 h 5.08 (0.2) (2.205) 370 (14.57) ±0.2 (±.008) 4.75 (.187) ±3.25 (±.128) DIMENSIONS = MM (INCHES)
Date Rev. Reason
Revision History
11/02/2005ɹɹɹAɹɹɹɹɹɹInitial issue PRCP-R SERIES Revision : H Issue date : 06/02/15 12/12/2005ɹɹɹBɹɹɹɹɹɹUpdated UL, CSA, TÜV File Number 06/01/2007ɹɹɹCɹɹɹɹɹɹUpdated Packagingoptions 07/15/2011ɹɹɹDɹɹɹɹɹɹUpdated Typical Part Marking 02/20/2013ɹɹɹEɹɹɹɹɹɹUpdated Environmental Characteristics 10/02/2013ɹɹɹFɹɹɹɹɹɹUpdated Tape and Reel Specifications 09/23/2014ɹɹɹGɹɹɹɹɹɹUpdated Tape and Reel Specifications 06/02/2015ɹɹɹHɹɹɹɹɹɹUpdated Features (Added halogen free )