SS . Thank you very much for purchasing our product. For safe and proper use of the product, please thoroughly read this manual and understand the contents before ELECTRONIC PRESSURE SWITCH using. Also, please keep this manual in a safe place for future reference. | S For more detailed information please ask for the nearest distributor or the following sales center. C€ [Compliance with EMC Standards] COPAL ELECTRONICS INSTRUCTION MANUAL Ver.1.0 Nishi-Shinjuku Kimuraya Bidg. , 7-5-25 i Nishi-Shinjuku Shinjuku-ku Tokyo 160-0023, Japan Phone. : (03)3364-7055 EE AN CAUTION.--this caution mark describes when there is a possibility that user may suffer from damage or physical damage may occur if the product is used improperly. AX CAUTION + The product is neither drip proof nor dust proof structure. Never use it under the condition where water or oil drips, dust rises, or corrosion occurs. + Do not use corrosive gases or liquids as pressure media. + Do not apply a pressure that exceeds the maximum pressure. * Do not short-circuit the output terminals of the switch to other terminal. Also, do not connect a load in which a current over 80mA may flow to/from the switch. Otherwise, the internal circuitry may be damaged. + When handling the product, be sure to pick up the body and not to give an excessive force to the cable. + When performing piping work on the product, be sure to hold the product on the port section and tighten pipes with torque less than the specified torque. + For stability, use a regulated DC power supply. Surge absorbing circuits (diodes, varistors, etc.) are necessary if inductive loads such as relays and solenoids are connected to the same power line as the PS6. Ifusing a DC power supply unit such as a switching power supply, the FG terminal should be earthed. (See the figure below.) + Use pH neutral detergents to clean the body. Do not use lacquer Unit poner supply peer line thinner and other solvents for cleaning. * aC Ba input input power power FG Earthing of the Surge absorbing circuit FS terminal MODEL NUMBER DESIGNATION Please identify the model number of the product you purchased. Ps 6 -DOODOO00 Fitting part type R : R1/8 with M5 female screw M : MS female screw Switch output type A : Oneswitch output (variable hysteresis) and Analog output Pressure range W : Two-switch output (fixed hysteresis) 102V : 0~—100kPa Output transistor configuration 102G : 0~100kPa N : NPN open collector 103G : 0~IMPa P : PNP open collector ou

When using R1/8 fitting: Use a wrench on the port section of the body to tighten with a torque of 4.9 N-m or less. Apply sealing tape if necessary. When using commercially available fitting for M5 female screw: Hold the switch on the port section. Tighten the fitting with a wrench with a torque of 0.49 N-m or less. A Do not directly hold the switch body when tightening. Do not use a wrench to any other part than the port section when tightening. Such handling may cause a breakage of the switch. The wires should be connected as shown in the table below. Be sure to connect the wires properly. CAD type OWD type Brown Power supply | Power supply Blue Common Common + Be earthing the shield wire if necessary. DAD type (one switch output) Pressure measurement mode ‘Switch setting mode a,Place the display selector switch (MODE) in the "SW" position. 2 aw ae ads b.Turn the pressure setting trimmer (SET) to set the switch operating pressure. Ao2i:) @oo [-58 Soo c.Turn the hysteresis adjustment trimmer (HYS) to get your desired hysteresis. d.Place the display selector switch (MODE) back in the "ME" position. @OW( type (two switch outputs) Pressure measurement mode Switch 1 setting mode a.Place the display selector switch (MODE) in the "S1" position. zl ri Co @ (-58 OO @ b.Turn the pressure setting trimmer 1 (SET1)to set the switch 1 operating pressure. || “20 LN) war gu ee vol SED sce ers ee c.Place the display selector switch (MODE) in the "S2" position. ‘Switch 2 setting mode d.Turn the pressure setting trimmer 2 (SET2) to set the switch 2 operating pressure, = —e ¢.Place the display selector switch (MODE) back in the "ME" position. Soo Lal Moe es STE >For further precise setting, apply the pressure and get the optimum pressure level by adjusting trimmers several times. +The setting range of the switch, adjustable range of the setting trimmer in other words, does not agree with the rated indication range of the display. Even though the indication of the display is “ 0 through 99", the switch can be set at the pressure under 0 or over 99 with the extra margin of a few% FS. aN When setting the display selector switch and the pressure-setting trimmer, be careful not to apply too much force to them. ‘The allowable torque for the display selector switch and the pressure setting trimmer should be no more than 0.025 N-m. NAC type (one NPN output) PAC type (one PNP output) pot batch stat LD over supply brown) in status LED B o O Paver supply bron Oa talog ut (nhite) ‘Switch output lack) i Pressure Poe LQ Ft om Pressure Sie re + | Switch outout Bleck) D> A Crnsog output ite) wm © i | Tet i ¢ | | Ces Oconron lve} comntpar BB) Ton ONC. held thesion gh Shei NWL type (two NPN outputs) @PWC type (two PNP outputs) ‘Switch status LED ‘Switch status LED ¢ Po Ly brown) ¢ & foe sly Fen & ae Power supply frown) & | a= & | [A QT site utput black) Pressure rit © +] bat Loo Pressure Stuit © t o “ae 5 © common {blue} ‘Poorman fiver . oe Seen eS TIER, phew TR, phe e

CADAL FLECTDAAC? OUTLINE DIMENSIONS (unit:mm) CDUIOR type (Fitting part : R1/8 with MS female screw) {Sriteh states LEDI (eed) \\ pgwitch status LED? (ereen) | For two-switch outeut model Pressure port) Pelvacetal 7. er = Ci Liaae2s PS | / ‘dyst is-sett tril WHIMS MILER RMAT ae © /. Wises te'set the sviten't tor tuecsvited ovtout node! Pressure-setting trimmer ‘H Used to set the switch | for two-switch output model ry Ri/B #34 aouab ine tot case . Polycarbonate A “4 a ay ff — M5, deat ns ie rae “t-core shielded cable)

4.5 Soft vinyl chloride

8.513] 52.505 L=1500150. UIC type (Fitting part : M5 female screw) Seiteh status LEDI (red) \\ Switch, status LED? (ereen! Pressure port \\ ‘# For two-switch outout model Polvacetal _—— 3 iss w { “ hyst: sett t PP astadionl Seitenise/ti/ng // Hisee'ta'set the eiteh 2 tor twe-owiteh outout ode! ‘/Pressure-setting trimmer 10 HUsed to set the switch 1 for two-switeh output node! fl 243.3 Mounting hole tase _ . Polycarbonate A dj & 2 asl — 9 ——— M5, depths 7 hing AA-core shieidee cable [483 45 Soft vinyl calorie 8.503 52,505 ‘L=1500150_ MAJOR SPECIFICATIONS General specifications G auge pressure (indicator) een Operating temperature | =10~60°C Storage temperature | —20~70°C Conpensiedtemerte |v | Pressure range | 10eV 1026 1036 Rated pressure =100kPa 100kPa 1.0MPa Maximum pressure 200kPa 200kPa 1.5MPa Breakdown pressure | _500kPa 500kPa 2.0MPa Power supply Driving power voltage | 12~24V (+108) | Current consumption | 35mA maximum (No load switch "ON" )

CAPA! ELECTDARICE @Switch outputs [_Stinrrange | Rated Sd | Setting method _|_ Adjustable with single turn trimmer Number of CAC type: 1 settable output CWC type: 2 Hysteresis CAC) type: about 0 ~15% FS (adjustable) CWO type: about 2% FS maximum (fixed) Working chart Hysteresis ON fh OFF en | OkPa Setting Rated pressure Switch rating 30V, 80mA maximum (per output) Residual voltage NCO type: 0.8V max. (at flowin current load of 80mA) POO type: 1.2V max. (at flow-out current load of 80mA) [Accuracy |) £3% FS max. (0~50°C, reference temperature 25°C) @Pressure indication Number of digits of display 2 digits Display element | LED (red) Pressure range 102V 102G 103G Rated indication —0~—99kPa_| _0~99kPa -0~.99MPa Sampling cycle Approx. 4 times per second Accuracy £3% FS£2 count (0~50°C, reference temp. 25°C) Analog output (IAC) type only) ZERO voltage 140.1V SPAN voltage 4£0.1V Output current 1mA max. (output load should be 5k minimum) ‘Thermal error ZERO : £0.1% FS/'C SPAN : 0.1% FS/C Linearity/Hysteresis | 0.5% FS @EMC [Standard | BN61326—1 : 19977A1: 1998 [___Accuraey | tors WARRANTY ‘This product can be covered by one-year warranty. COPAL ELECTRONICS warrants that the any part of the product, which proves to be defective due to the design and/or manufacturing of COPAL ELECTRONICS within one year from the date of delivery, will be repaired or replaced, free of charge. Note that the warranty will only be applied to the product alone, not to damages induced by any failure of the product. However, the warranty will not be applied in any of the following cases. (Failure and damage caused by improper use not conforming to the instruction manual or negligent handling. @Failure and damage caused by inappropriate modification, adjustment or repair. Failure and damage caused by natural disaster, fire or other act of God.