PS40 COPAL | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 1
Technical content
When using the O-ring ZH 7. INTERNAL ELECTRICAL SCHEMATICS 9. MAJOR SPECIFICATIONS COPAL ELECTRONICS Fitting “O"ring SD © Type NAR and NAM (one NPN switch) D General specifications suitable Mounting block) Put the fitting O-ring in the Pressure reference Gauge (Referring to atmospheric pressure) Tyo groove and connect the “4 Switch status indicator Pressure media Non-corrosive MS screw G a Power gases ELECTRONIC PRESSURE SWITCH PS 4Q ‘ GS ‘counting block to the pressure port fx ‘ower supply (brown) Frese mel ge fntares C€ marking \\ ‘ wp head with suitable M3 screws with [ [en] Storage temp.range —20~80°C (Compliance with EMC Standards) ae : the torque up to 0.29N-m. Win 6 Sun (bia) Compensated temp.range 0~S0°C INSTRUCTION MANUAL vVer2.1 N O-ring “D> a] ct ‘Analog (white) ene] 02 501G 102G 103G 7 :, SS 102V P8(JIS B 2401) 3 | | 2) it Thank you very much for purchasing our product. In order to derive its ce S Rated pressure | —100kPa | _50kPa 100kPa 1MPa desired ch ics and utilize it with high reliability, please thoroughh ® S 501G,102G,103G | P10 IS B 2401) & gommon ue) lesired characteristics and utilize it with high reliability, please thoroughly 5 Shield (N.C.) Maxinum pressure) 200kPa 100kPa 200kPa 1.5MPa read this manual and understand the contents before using. Also,please keep or ‘ this manual and read again as necessary. wet pe 4. INSTALLATION OF THE MAIN BODY Type PAR and PAM (one PNP switch) Operating voltage 108~30V DC cs DSide face instalation Bottom face installation 7 Sah sas rae Tre] NAR. NAM |SPARIPAMI) NWR Nw | PHRIPWE IMPORTANT INFORMATION and CAUTION ax 5 ay ve neither dri ee a a, Es 40 Power supply (brown) Current 17mA or less 25mA or less DThe product is neither drip proof nor dust proof structure. Never use it under MEE eA Apassony aw consumption| (No load switch “ON”) | (No load switches “ON") the condition where water or oil drips , dust rises, or corrosion occurs. OL iP LS Wein 7 ‘Analog (white) Never apply corrosive gases nor liquids for pressure media oy A sua A& Dol Pressure circuit © ‘Switch (black) @ Switch @Never take in the over-pressure exceeding the maximum pressure. BAY 2 wa screw D> 2] tem | NAR.NAM | PAR,PAM | NWR.NWM @Never short circuit the switch output to the other terminals, nor them connect ® [SKS = ~ i PAR PAM | RN to the low impedance load that would allow the output current over 80mA. SND ON ®) J Common (ius) z - : = “ . 4 AEN, Shield (N.C.) Setting Adjustable with the 3-turn trimmer (s) ‘These conduct might damege the internal circuitry. A ec Use the stable DC power supply for the power source. Surge absorbing circuit QS . . No.of 1 2 Giodes,varistor,ete,) is opomer — Untpower Accessory Het Oy eee. @ Type NWR and NWM (two NPN switches) switches | necessary if inductive load i MS screw BENS 7 Switch status Indicator __| Adjustable,about 1~15% oo ° AC pc Se > red—| Power supply (brown) Hysteresis of the set value with Fixed,28FS or less such as relay or solenoid S ; B®. SAIN Qa o the Lturn trimmer was connected tothe power [I (A) oa ore Re SX SSP goon | 4 [ Tem) — a line and/or to the switch s Fa Y, S) RS ae Sap) A 2 ° oN oN FG terminal on the unit YQ ») D> , P Switch (white) OFF, OFF power supply should be y A) SD) 9 ~ 2 © [2 / | ; Working chart aa @When handling the product, > a) eee = . . @Bottom face installation 2 ES be sure to pick up the body and not to give the excessive force to the cable, in ganging configuration PNY +P <—_> Dse the neutral detergent when cleaning the body, also do not use the " OO uate @ Type PWRand PWM (two PNP switches) fesse pressure |premsere Ma serew solvents lke lacquer thinner, rea — (Snitch stats ncoator Rating | 28008 | oma | sv soma | aogafated 1. PART NUMBER DESIGNATION 5. WIRING ren t+ Power supply (brown) or less oni orless ores Wiring connection must be done as instructed below without fail. Aa & Switcht_ (back) Residual | 08V max | 12V max. | 08V max | 12V max Please confirm the part number of the product you purchased. " : 4 ol esidual atflowin | atflowout | atflowin | atflow-out Type NAR, NAM, PAR and PAM Type NWR, NWM, PWRand PWM p Main © Switch, voltage | currentload_ | currentload | currentload | current load ‘Type Color Connection Color Connection ‘D> ore oF soma cred soma cs) pat ek I I z ps40-OO0C-O04 Ble GND The END comma uct Accuracy (0~S0°C reference temp. 25°C) | Black : 5 4 ac Switeh out Black Switch out 1 Shield (N.C.) _ Pressure range L Shape of the fitting portion Whine T ‘Analog out White 1 -Switch out ® Analog output (1~SV) 102V:0~-100kPa R:R1/8 with M5 female screw bore Item ~~!" | NAR,NAM | PAR,PAM. 501G:0~50kPa ‘M-Flat head with M5 female screw bore and O-ring UNTO Never short-circuit the switch output(s) to the other terminals,nor 8. OUTLINE DIMENSIONS ZERO voltage. 1+0.1V 102G:0~ 100kPa groove then connect to the low impedance load that would allow the output current over i SPAN volt ‘aoiv 103G:0~ 1MPa 80mA. These conduct might damage the internal circuitry. D Type NAM, PAM, NWM and PWM jolage . . Output (Fitting shape : Flat head with MS female screw bore and O-ring groove) ImA or less Switch configuration Aone switch output with variable hysteresis circuit gS ETTING Pressure por yp Case Output current | _Resistance should N:NPN_ P:PNP and one analog output . (Polyacetal Z| (Polycarbonate) be 5k or more Wetwo switches (fixed hysteresis) DTypeNARNAM,PARand PAM (onesviteh) pressure pot mo Ll eee “Thermal error ZERO OAMFS/C oF les5 | ctype NWR NWM « ~ Swit indicator a Get the appropriate hysteresis 1 jermal error] * 2. ACCESSORIES eee ea caduainon inner vale by adjusting the oes oat tT ‘all SPAN _0.18PS/C or less | PWRand PWM don't have Pan head small screws and spring lock washers---2pcs each \\ f° (Setting valve wit increase as the hysteresis adjustment trimmer. oepnas / 225 _,| 11, | \\ 263.3 Mounting hole Linearity/ Hysteresis -£0.5%FS or less the analog output. INSNA,_/ trimmer being tuned clockwise) _b Apply the pressure you desire 7 / 2-943 Mounting hole a Screw driver for adjustment ‘Ipe < GOD - Hysteresis adjustment immer the switch to be turned on and a/ 5) EMC y LY etipuakealincesssss get the switching point by rt [3 )O\\ (_) ENSSO11 : 1998 (Group, Class A) | BELL tne vimmer being tumed clockwise) adjusting the switching point x ¥ oa EN60947—1 : 1997 3. PIPING SS aS adjustmenet trimmer, @©)e «2 OT | ‘Aoouracy | 4 5%FS o . on . OQ | Seanativer Repeat the above procedures | © 3 ON curacy + When using the R1/8 fitting part @/When using MS female screw bore fora couple of times and get the +e! a [Be SES (0) 10. Warranty A art oO exact point. / [20 { #8 45 Nidec Copal Electronics warrants the products for the period of one year after de>, iw; PATTON] be aware of not applying too much force to the trimmers, The 15 L 46 . Le1s00 | the date ofthe customers recip, We wll repair the troubled products caused S —D applying torque to the hysteresis adjustment trimmer should be up to 0.044N-m. by our improper designing and/or production control at our cost. Our warranty
6 SS > is limited to the products only, not on another damage that is caused by the
2 RSA Type NAR, PAR, NWR and PWR product malfunction. 4 Som Pree > Type NWR, NWML PWRand PWM. (ovo sitehes Fitting shape : R1/8 with MS female screw bore) Please note that the repairing cost resulted from the following matters are out of ONS y a Apply the pressure you desire jy Onse our responsibility. we? A oy) 5 Switch status indicator 2 (green) thee oech loo be bed on and Proseis pot — /\\__ Polycarbonate) (1) Trouble and damage caused by mishandling or careless usage against the Pressure ~ wy \\_ [Switch status indicator 1 (red) get the switching point by = a a a —— handlimg manual. port ENN ic (3 IN \\ switching point adjustment tmmert adjusting the switching point Cl aL @) Trouble and damage caused by improper remodeling, adjustment or repair. 0 ROD (Setingjave wnincesse ase adhstment immer. at OQ QL!) @) Trouble and damage caused by natural disaster, fire or any other irresistible g x ‘rimmer being turned clockwise) (The red LED lights up when the Pressurepot ” # 225 || 11 || \\2-888Mounting hole force. Hold the pressure port block and wre- Support the pressure port block and NZ} switching point adusiment Switch I turns “ON") 5 doth 5 backbonnate ) Replacement of maintenance or consomption parts. nch up the suitable fitting with the wrench up the suitable fitting with the NJ lat ptinmert_(Setiravaliewl'y Apply the pressure you desire 7 2:93: Mounting hole ————————E torque of up to 4.9N-m. Be sure not to torque of up to 0.49N-m. Be sure that OB ined dockwiaa) "the switeh 2 to be turned on and / == )O\\ (_} For more detailed information please ask for the nearest . on one ‘ ‘kis ) ct the switching point b = 3 — distributor or the following sales center. wrench the other portion except the _pressure port block is the only portion u Screw diver a et a nihe ahitching pot ge ‘a OD L| pressure port block. Use the sealing to be hold when piping. foradjustment Adjusting the switching point “tl “ adjustment trimmer. 3 |@) tape if necessary. (The green LED light up when f IB = Is the switch 2turns"ON". y Nishi-Shinjuku Kimuraya Bidg. , 7-5-25 PATTY Never tighten the PS40 with holding the main body. This may e switch Ztums'ON") rie! | | 4s NishiShinjukku Shinjuku Tokyo 160-0023 , Japan physically break the switch or affect its performance characteristics. DANTON] Be aware of not applying too much force to the trimmers. 18 85) 45 L100 Phone. : (03) 3364-7055 J