P6Y1205S HY-LINE | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 2
Technical content
6W DC-DC Converter P6Y-Series
- Wide 2:1input range
- Up to 3500 V DC isolation
- Continuous short circuit protection
- None conductive plastic case Model selection guide Typ Input nominal voltage [VDC] Output voltage [VDC] Output current [mA] Efficiency typ. [%] Single output P6Y1205S 9...18 5.0 1200 77 P6Y1209S 9...18 9.0 667 75 P6Y1212S 9...18 12.0 500 80 P6Y1215S 9...18 15.0 400 80 P6Y1224S 9...18 24.0 250 80 P6Y2405S 18...36 5.0 1200 80 P6Y2409S 18...36 9.0 667 83 P6Y2412S 18...36 12.0 500 83 P6Y2415S 18...36 15.0 400 83 P6Y2424S 18...36 24.0 250 83 P6Y483R3S 36...72 3.3 1400 75 P6Y4805S 36...72 5.0 1200 80 P6Y4809S 36...72 9.0 667 83 P6Y4812S 36...72 12.0 500 83 P6Y4815S 36...72 15.0 400 83 P6Y4824S 36...72 24.0 250 83 Dual output P6Y1205D 9...18 ±5.0 ±600 77 P6Y1209D 9...18 ±9.0 ±334 75 P6Y1212D 9...18 ±12.0 ±250 80 P6Y1215D 9...18 ±15.0 ±200 80 P6Y1224D 9...18 ±24.0 ±125 80 P6Y2405D 18...36 ±5.0 ±600 80 P6Y2409D 18...36 ±9.0 ±334 83 P6Y2412D 18...36 ±12.0 ±250 83 P6Y2415D 18...36 ±15.0 ±200 83 P6Y2424D 18...36 ±24.0 ±125 83 P6Y4805D 36...72 ±5.0 ±600 80 P6Y4809D 36...72 ±9.0 ±334 83 P6Y4812D 36...72 ±12.0 ±250 83 P6Y4815D 36...72 ±15.0 ±200 82 P6Y4824D 36...72 ±24.0 ±125 82 Input voltage range reach from 4.5V to 72V and the output voltage range reach from 3.3V to 24V Suffix: “H” for 3.5kV isolation voltage Page 1 of 2 Deutschland: Schweiz: Inselkammerstraße 10 Gründenstrasse 82 D-82008 Unterhaching CH-8247 Flurlingen Tel.: 089 614 503-10 Tel.: 052 647 42 00 E-Mail: power@hy-line.de E-Mail: power@hy-line.ch
6W DC-DC Converter P6Y-Series Specifications Input Voltage range 12 V DC, 9…18 V DC
24 VDC, 18…36 V DC
48 VDC, 36…72 V DC
Isolation: Rated voltage 1500 V DC, Standard
3500 VDC, Suffix “H”
Resistance 10 9 Ω Capacitance 390 pF, typ. Output Voltage accuracy ± 1%, max. Voltage balance (dual outputs) ± 1% Ripple and noise (at 20 MHz BW) 60 mVp-p, max. Short circuit protection Continuous Short circuit restart Automatic Line voltage regulation ± 0.5%, max. Load voltage regulation ± 0.5%, max. Temperature coefficient ± 0.02% / °C Dimensions Pin connections Pin 1.5kV version 3.5kV version Single Dual Single Dual 1 +V Input +V Input Omitted Omitted 2 N.C. -V Output -V Input -V Input 3 N.C. Common -V Input -V Input
9 Omitted Omitted Omitted Common
10 -V Output Common Omitted Omitted 11 +V Output +V Output N.C. -V Output 12 -V Input -V Input Omitted Omitted 13 -V Input -V Input Omitted Omitted 14 +V Output +V Output +V Output +V Output 15 -V Output Common Omitted Omitted
16 Omitted Omitted -V Output Common
22 N.C. Common +V Input +V Input 23 N.C. -V Output +V Input +V Input 24 +V Input +V Input Omitted Omitted Page 2 of 2 General Efficiency 74% to 83% Switching frequency 100 kHz…400 kHz Environmental Operating temperatur (ambient) -40 °C to +71 °C Case temperature 100 °C max. Storage temperature -40 °C to +125 °C Derating None required Humidity Up to 90%, None condensing Cooling Free-air convection Physical Dimensions 31.75x20.32x10.16 mm Weight 17 g plastic standard, 19 g metal suffix “M” Case material None conductive plastic Life Support Policy : HY-LINE does not authorize the use of any of its products for use in life support devices or systems without the express written approval of an officer of the Company. Life support systems are devices which support or sustain life, and whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in significant injury to the user. Rev: 2.06 f Deutschland: Schweiz: Inselkammerstraße 10 Gründenstrasse 82 D-82008 Unterhaching CH-8247 Flurlingen Tel.: 089 614 503-10 Tel.: 052 647 42 00 E-Mail: power@hy-line.de E-Mail: power@hy-line.ch 31.75 20.32 27.94 15.24 0.5 2.54 10.16 3.05 min. P6Y1205S PHI-CON 0.5 All dimensions in mm Tolerance ±0.25 mm 1 12 bottom view 24 13