DATASHEET SEARCH SITE | WWW.ALLDATASHEET.COM

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 5

Technical content

50 W DC-DC Converter P50C-Series

Deutschland: Schweiz: Inselkammerstraße 10 Hochstrasse 355 D-82008 Unterhaching CH-8200 Schaffhausen Tel.: 089 614 503-10 Tel.: 052 647 42 00 E-Mail: power@hy-line.de E-Mail: power@hy-line.ch

  • 2:1 wide input voltage range
  • High efficiency up to 92 %
  • Over current protection
  • Over voltage protection
  • Over temperature protection
  • Continuous short circuit protection
  • Adjustable output voltage
  • On/Off - remote control input
  • Soft start
  • Standard 2" x 1" package Model guide Specifications Part number designation key PHI-CON Output power Series designation Input voltage range Output voltage Output configuration P 50 50 W C 12 9…18 V 3R3 3.3 V S single output 24 18…36 V 5 5 V SK Single outp. with heat sink 48 36…75 V 12 12 V 15 15 V Page 1 of 5 Type Input voltage Input current Output voltage [VDC] Output current Efficiency typ. [%] Capacity load max. [µF] nominal [VDC] range [VDC] no load [mA] max. full load [mA] typ. [mA] min. [mA] max. P50C123R3S 12 9...18 120 3020 3.3 0 10000 90 26000 P50C1205S 12 9...18 170 4600 5.0 0 10000 89 17000 P50C1212S 12 9...18 50 4700 12.0 0 4167 89 3300 P50C1215S 12 9...18 50 4630 15.0 0 3333 89 2200 P50C243R3S 24 18...36 70 1500 3.3 0 10000 91 26000 P50C2405S 24 18...36 90 2250 5.0 0 10000 91 17000 P50C2412S 24 18...36 40 2300 12.0 0 4167 91 3300 P50C2415S 24 18...36 30 2300 15.0 0 3333 91 2200 P50C483R3S 48 36...75 50 750 3.3 0 10000 91 26000 P50C4805S 48 36...75 60 1130 5.0 0 10000 92 17000 P50C4812S 48 36...75 30 1150 12.0 0 4167 91 3300 P50C4815S 48 36...75 40 1140 15.0 0 3333 89 2200 General Switching frequency 250 kHz, typ. Standard in accordance with EN-, IEC-, cUL-, UL 60950-1 EN-, IEC-, cUL-, UL 62368-1 Radiated emissions EN 55032 class A Conducted emissions EN 55032 class A ESD IEC 61000-4-2 pref. criteria A Radiated immunity IEC 61000-4-3 pref. criteria A Fast transient (see figure 3) IEC 61000-4-4 pref. criteria A Surge (see figure 3) IEC 61000-4-5 pref. criteria A Conducted immunity IEC 61000-4-6 pref. criteria A PFMF IEC 61000-4-8 pref. criteria A Reliability calculated (MIL-HDBK-217 F) @ 25 °C MTBF > 200 000 h Environmental Operating ambient temperature -40 … 95 °C (with derating) -40 … 50 °C (without derating) Storage temperature -40 °C …125 °C Cooling Air convection 30…60 LFM (16...33 cm/s) Thermal impedance P50CxxxxS: 9.5 K/W P50CxxxxSK: 8.5 K/W Maximum case temp. 110 °C, max. Over temperature protection 115 °C, typ Storage humidity 95 %, non condensing Physical Dimensions P50CxxxxS: 50.8 x 25.4 x 12 mm P50CxxxxSK: 50.8 x 25.4 x 18.1 mm Weight P50CxxxxS: 45 g P50CxxxxSK: 56 g Case material Copper Potting material Epoxy, UL94V-0 rated RoHS compliant yes Absolute maximum ratings Input surge voltage 100 ms max. P50C12xx: 25 VDC P50C24xx: 50 VDC P50C48xx: 100 VDC Soldering temperature ≤ 260 °C, ≤ 10 s, ≥ 1.5 mm distance from case Input Input Filter: Pi- type Start up voltage P50C12xx: 8.6 V, typ. P50C24xx: 17.8 V, typ. P50C48xx: 24 V, typ. Under voltage lockout P50C12xx: 7.9 V, typ. P50C24xx: 16 V, typ. P50C48xx: 29 V, typ. Start up time 50 ms, typ. Input reflected ripple current 20 mAp-p, typ (see fig. 1) Remote control input Pin 3 (see figure 4a & 4b) “On” 3.0…12 V or open input “Off” Short to -Vin or 0…1.2 V Input idle current at Ctrl "Off" 5 mA at nominal Vin Isolation input to output Isolation voltage, Input to output or to case, 1 minute tested 1600 VDC, min. Resistance 109 Ω, min. Capacitance 2000 pF, typ. Output Over voltage protection with Z-diode clamp P50Cxx3R3: 3.9 V P50Cxx05: 6.2 V P50Cxx12: 15 V P50Cxx15: 18 V Voltage accuracy ±1 % Voltage trim range ±10 %, max. (see figure 5) Ripple and noise (at 20 MHz BW) 100 mVp-p, max. (see figure 2) Short circuit protection Hiccup, automatic recovery Line regulation ± 0.5 %, max. Load voltage regulation at 0…100% load change ± 0.5 % Temperature coefficient ± 0.02 % / °C Transient recovery time at 25 % load change steps 250 µs, typ. Transient response deviation at 25 % load change steps ± 3 %, max. Over load protection 140 %, max. of full load

Deutschland: Schweiz: Inselkammerstraße 10 Hochstrasse 355 D-82008 Unterhaching CH-8200 Schaffhausen Tel.: 089 614 503-10 Tel.: 052 647 42 00 E-Mail: power@hy-line.de E-Mail: power@hy-line.ch Figure 1 Input reflected ripple current measure circuit Figure 2 Output ripple & noise measure circuit Figure 3 Recommended circuit to meet (EFT) IEC61000-4-4 and (Surge) IEC61000-4-5 Output ripple & noise reduction Figure 4a On / Off remote control circuit for positive logic Page 2 of 5 47 µF + +Vin Load -Vout -Vin/GND +Vout 12 µH Measure point DC DC ESR <1 Ω @ 100 kHz 1 µF ceramic +Vin -Vout -Vin/GND +Vout Load DC DC +Vin -Vin/GND -Vout +Vout Load DC DC 1 µF cer. 10 µF 10 µF +Vin -Vin/GND Ctrl +Vin Load -Vout +Vout DC DC Remote control input on: 3.5 V…≤12 V or open off: 0…1.2 V -Vin/GND To reduce ripple and noise, it is recommended to use a ceramic capacitor and an electrolytic capacitor. The input reflected ripple current is measured through a source inductor 12 µH and a source capacitor Cin 47 µF, ESR <1 Ω at 100 kHz at nominal input voltage and full load. 220 µF, 100 V + +Vin Load -Vout -Vin/GND +Vout DC DC KY-Series Nippon Chemicon

Deutschland: Schweiz: Inselkammerstraße 10 Hochstrasse 355 D-82008 Unterhaching CH-8200 Schaffhausen Tel.: 089 614 503-10 Tel.: 052 647 42 00 E-Mail: power@hy-line.de E-Mail: power@hy-line.ch Figure 4b On / Off remote control circuit for inverse logic Figure 5 Trim circuit example Output voltage trim function allows the user to increase or decrease the output voltage set point. the module maybe connected with an externalresistor (R trim) between Trim and either +Vout or -Vout pin. By adjusting Rtrim, the output voltage can be changed by 10 % of nominal output voltage. Page 3 of 5 P50Cxx3R3S Trim up 1 2 3 4 5 6 7 8 9 10 [ % ] P50Cxx05S Trim up 1 2 3 4 5 6 7 8 9 10 [ % ] P50Cxx12S Trim up 1 2 3 4 5 6 7 8 9 10 [ % ] P50Cxx15S Trim up 1 2 3 4 5 6 7 8 9 10 [ % ] +Vin -Vin Load 5 -Vout 4 +Vout DC DC

6 Trim

+Vin -Vin Load 4 -Vout 4 +Vout DC DC +Vin -Vin/GND Ctrl. Load -Vout +Vout DC DC Remote control input off on on off

Deutschland: Schweiz: Inselkammerstraße 10 Hochstrasse 355 D-82008 Unterhaching CH-8200 Schaffhausen Tel.: 089 614 503-10 Tel.: 052 647 42 00 E-Mail: power@hy-line.de E-Mail: power@hy-line.ch Page 4 of 5

Deutschland: Schweiz: Inselkammerstraße 10 Hochstrasse 355 D-82008 Unterhaching CH-8200 Schaffhausen Tel.: 089 614 503-10 Tel.: 052 647 42 00 E-Mail: power@hy-line.de E-Mail: power@hy-line.ch Mechnical dimensions Dimensions in mm 1. Pin diameter tolerance: ± 0.05 mm 2. Pin length tolerance: ± 0.35 mm 3. Pitch tolerance: ± 0.35 mm 4. Case tolerance: ± 0.5 mm 5. Stand-off tolerance: ± 0.1 mm Page 5 of 5 Pin assignment 1 +Vin 2 -Vin 3 Rem. Ctrl. 4 + Vout 5 - Vout PHI-CON is a trademark of HY-LINE Holding GmbH. Only for professional use by professionals ! Not for resale or distribution to the general public in any way ! Read the instructions carefully before using! Life Support Policy: HY-LINE does not authorize the use of any of its products for use in life support devices or systems without the express written approval of an officer of the Company. Life support systems are devices which support or sustain life, and whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in significant injury to the user. Rev: 20181004 f