6 W DC-DC Converter P6N-Series
Deutschland: Schweiz: Inselkammerstraße 10 Hochstrasse 355 D-82008 Unterhaching CH-8200 Schaffhausen Tel.: 089 614 503-10 Tel.: 052 647 42 00 E-Mail: power@hy-line.de E-Mail: power@hy-line.ch
- Wide 2:1 input range
- -40...85 °C operation temperature range
- Isolation up to 3000 VDC
- Continuous short circuit protection
- Under voltage protection
- Efficiency up to 85 %
- DIL24 plastic case Model guide Add suffix “H” for 3 kV isolation voltage Page 1 of 5 Type Input voltage Input current Output voltage [VDC] Output current Efficiency [%] typ. Capacitive load (note 1) [µF] max. nominal [VDC] range [VDC] No load [mA] typ. Full load [mA] typ. [mA] min. [mA] max. Single output P6N123R3S 12 9...18 7 515 3.3 0 1400 76 470 P6N1205S 12 9...18 7 635 5.0 0 1200 80 470 P6N1212S 12 9...18 10 600 12.0 0 500 84 100 P6N1215S 12 9...18 10 600 15.0 0 400 85 100 P6N1224S 12 9...18 20 610 24.0 0 250 83 47 P6N243R3S 24 18...36 7 260 3.3 0 1400 75 470 P6N2405S 24 18...36 7 315 5.0 0 1200 80 470 P6N2412S 24 18...36 7 300 12.0 0 500 84 100 P6N2415S 24 18...36 7 300 15.0 0 400 84 100 P6N2424S 24 18...36 10 305 24.0 0 250 83 47 P6N483R3S 48 36...75 7 125 3.3 0 1400 77 470 P6N4805S 48 36...75 7 150 5.0 0 1200 83 470 P6N4812S 48 36...75 7 150 12.0 0 500 85 100 P6N4815S 48 36...75 7 150 15.0 0 400 85 100 P6N4824S 48 36...75 7 150 24.0 0 250 85 47 Dual output P6N123R3D 12 9...18 10 660 ±3.3 0 ±910 77 2 x 220 P6N1205D 12 9...18 10 625 ±5.0 0 ±600 81 2 x 220 P6N1212D 12 9...18 15 600 ±12.0 0 ±250 84 2 x 100 P6N1215D 12 9...18 20 600 ±15.0 0 ±200 84 2 x 100 P6N1224D 12 9...18 35 625 ±24.0 0 ±125 81 2 x 47 P6N243R3D 24 18...36 7 330 ±3.3 0 ±910 77 2 x 220 P6N2405D 24 18...36 7 315 ±5.0 0 ±600 80 2 x 220 P6N2412D 24 18...36 10 305 ±12.0 0 ±250 83 2 x 100 P6N2415D 24 18...36 15 300 ±15.0 0 ±200 84 2 x 100 P6N2424D 24 18...36 20 310 ±24.0 0 ±125 82 2 x 47 P6N483R3D 48 36...75 7 160 ±3.3 0 ±910 79 2 x 220 P6N4805D 48 36...75 7 150 ±5.0 0 ±600 83 2 x 220 P6N4812D 48 36...75 7 150 ±12.0 0 ±250 84 2 x 100 P6N4815D 48 36...75 7 150 ±15.0 0 ±200 84 2 x 100 P6N4824D 48 36...75 15 160 ±24.0 0 ±125 81 2 x 47
Deutschland: Schweiz: Inselkammerstraße 10 Hochstrasse 355 D-82008 Unterhaching CH-8200 Schaffhausen Tel.: 089 614 503-10 Tel.: 052 647 42 00 E-Mail: power@hy-line.de E-Mail: power@hy-line.ch Specifications Note: All parameters are specified at Ta 25 °C, nominal input voltage and full load unless otherwise specified! *1 Specified by nominal input voltage and constant resistive load Fig.1 Measure circuit for reflected input ripple current Page 2 of 5 Input : Filter Pi Network Input reflected ripple current 20 mAp-p, typ. (see Fig. 1) Start up time @ Vin nominal & R-load 20 ms Under voltage protection P6N48xxx Start up 8.5 V, typ. Lock off 7 V, typ. P6N12xxx Start up 16.5 V, typ. Lock off 14.5 V, typ. P6N24xxx Start up 34.5 V, typ. Lock off 30 V, typ. Isolation: Input / output rated voltage 60 sec. Standard. 1500 VDC Suffix “H”: 3000 VDC Resistance input to output 109 Ω Capacitance 1 nF, typ. Output: Voltage tolerance ± 2 %, max. Voltage balance @ dual outp. ± 2 %, max. Cross deviation @ 75 % load difference between outputs ± 5 %, max. Line regulation ± 0.5 %, max. Load regulation ± 1.2 %, max. Temperature coefficient ± 0.02 % / °C Ripple and noise (at 20 MHz BW) <80 mVp-p, (see fig 2) <100 mVp-p, only P6Nxx24D Over load protection 160 % of specified current Short circuit protection Continuous, automatic restart Transient recovery time @ 25 % load steps 300 µs, typ. Transient response deviation @ 25 % load steps ± 3 %, ± 5 % only P6Nxx3R3x General: Switching frequency 330 kHz, typ. Safety standard IEC, EN, UL, cUL 60950-1 Reliability calc. MTBF MIL-HDBK-217 F @ 25 °C >800000 h Environmental: Operating ambient temperature range -40…85 °C, see SOA -40… 60 °C, without derating Storage temperature range -55…125 °C Case temperature max. 100 °C Humidity 95 %, max., not condensing Cooling Free air convection Physical : Dimensions 31.75 x 20.32 x 10.16 mm Weight 13 g Case material Black plastic, UL94V-0 rated Potting material Epoxy resin, UL94V-0 rated EMC in accordance with Radiated emissions EN55032 class A Conducted emissions EN55032 class A ESD IEC61000-4-2 perf. criteria A RS IEC61000-4-3 perf. criteria A EFT IEC61000-4-4 perf. criteria A Surge (see Fig. 3) IEC61000-4-5 perf. criteria A CS IEC61000-4-6 perf. criteria A PFMF IEC61000-4-8 perf. criteria A Absolute maximum ratings Input voltage P6N12xxx P6N24xxx P6N48xxx 25 VDC, 0.1 s, max. 50 VDC, 0.1 s, max. 100 VDC, 0.1 s, max. Soldering temperature 260 °C for 10 s distance 1.5 mm from case 47 µF + +Vin Load -Vout -Vin +Vout 12 µH Measure point DC DC ESR <1 Ω @ 100 kHz
Deutschland: Schweiz: Inselkammerstraße 10 Hochstrasse 355 D-82008 Unterhaching CH-8200 Schaffhausen Tel.: 089 614 503-10 Tel.: 052 647 42 00 E-Mail: power@hy-line.de E-Mail: power@hy-line.ch Fig.2 Measure circuit for output ripple and noise Fig.3 EMI filter circuit to comply IEC61000-4-5 performance criteria A Page 3 of 5 220 µF, 100 V + +Vin Full- load -Vout -Vin +Vout DC DC KY-Series Nippon Chemicon +Vin - Vin -Vout +Vout Load DC DC 1 µF ceramic
Deutschland: Schweiz: Inselkammerstraße 10 Hochstrasse 355 D-82008 Unterhaching CH-8200 Schaffhausen Tel.: 089 614 503-10 Tel.: 052 647 42 00 E-Mail: power@hy-line.de E-Mail: power@hy-line.ch Page 2 of 5 Page 4 of 5
Deutschland: Schweiz: Inselkammerstraße 10 Hochstrasse 355 D-82008 Unterhaching CH-8200 Schaffhausen Tel.: 089 614 503-10 Tel.: 052 647 42 00 E-Mail: power@hy-line.de E-Mail: power@hy-line.ch Dimensions Page 5 of 5 Pin assignment Single Dual 2 -V Input -V Input 3 -V Input -V Input
9 No pin Common Output
11 Not connected. -V Output 14 +V Output +V Output 16 -V Output Common Output 22 +V Input +V Input 23 +V Input +V Input PHI-CON is a trademark of HY-LINE Holding GmbH. Only for professional use by professionals ! Not for resale or distribution to the general public in any way ! Read the instructions carefully before using! Life Support Policy: HY-LINE does not authorize the use of any of its products for use in life support devices or systems without the express wr itten approval of an officer of the Company. Life support systems are devices which support or sustain life, and whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in significant injury to the user. Rev: 20171106 f All units in mm 1. Pin tolerance ±0.05 mm 2. Pitch tolerance ±0.35 mm 3. Pin length tolerance ±0.35 mm 4. Case tolerance ±0.5 mm