6W DC-DC Converter P6X-Series

  • 6 W maximum output power
  • Adjustable Output Voltage
  • 2:1 wide input voltage range
  • Five-Sided continuous shield
  • Small package 1.6" x 1" x 0.33"
  • Short circuit protection Model selection guide Typ Input nominal voltage [VDC] Input current full-load [mA] Output voltage [VDC] Output current [mA] Efficiency typ. [%] Capacitor load max. [uF] Single output P6X05S33 4.5…9 1131 3.3 1200 74 6600 P6X05S05 4.5…9 1370 5.0 1000 77 3000 P6X05S12 4.5…9 1519 12.0 500 83 1400 P6X12S33 9…18 573 3.3 1200 76 6600 P6X12S05 9…18 658 5.0 1000 80 3000 P6X12S12 9…18 617 12.0 500 85 1400 P6X24S33 18…36 286 3.3 1200 77 6600 P6X24S05 18…36 321 5.0 1000 82 3000 P6X24S12 18…36 309 12.0 500 85 1400 P6X48S33 36...75 143 3.3 1200 77 6600 P6X48S05 36...75 165 5.0 1000 80 3000 P6X48S12 36...75 155 12.0 500 85 1400 Dual output P6X05D12 4.5…9 1519 ±12.0 ±250 83 2 x 510 P6X12D12 9…18 617 ±12.0 ±250 85 2 x 510 P6X24D12 18…36 309 ±12.0 ±250 85 2 x 510 P6X48D12 36...75 155 ±12.0 ±250 85 2 x 510 Trimming Remote Control Page 1 of 2 Deutschland: Schweiz: Inselkammerstraße 10 Gründenstrasse 82 D-82008 Unterhaching CH-8247 Flurlingen Tel.: 089 614 503-10 Tel.: 052 647 42 00 E-Mail: power@hy-line.de E-Mail: power@hy-line.ch Output can be externally trimmed by using the method shown below. ( ) for dual output 5 (4) 6 (6) 7 (7) TRIM UP TRIM DOWN

6W DC-DC Converter P6X-Series Specifications Input Voltage range 5V type: 4.5…9 V DC 12V type: 9…18 V DC 24V type: 18…36 V DC 48V type: 36…75 V DC Filter L-C type EMC external filter capacitor for EN55022 class A 5V type: 220 µF / 16 VDC 12V type: 220 µF / 25 VDC 24V type: 100 µF / 50 VDC 48V type: 100 µF / 100 VDC Input surge voltage for 100mS max. 5V type : 15 VDC max. 12V type : 36 VDC max. 24V type : 50 VDC max. 48V type : 100 VDC max. Output Power 6 W max. Voltage accuracy ± 2% Minimum load 0% Line regulation ± 0.2% Load voltage regulation ± 0.5% between 10% and 100% load Ripple and noise (at 50 MHz BW) 100mVp-p max. Transient response recovery time 500 µs / 25% load step change Short circuit protection continuous, automatics recovery Voltage adjustability ± 10% Over current protection 150% Temperature coefficient ± 0.02% / °C Dimensions Derating Pin connections Pin Single Dual 1 + Input + Input

2 CTRL CTRL

4 N.C. Common 5 - Output - Output

6 Trim Trim

Switching frequency 100 to 1500 kHz Isolation voltage 500 V AC Isolation Resistance 50 Ω @ 500 V Isolation Capacitance 300 pF, max. Safety standards in accordance with IEC60950, UL60950, EN60950 MTBF Bellcore TR-NWT-000332 @Ta 40 °C, 100% stress: 1.5x10 hrs Environmental Operating temperature -20 °C to +70 °C (with derating) Storage temperature -40 °C to +85 °C Thermal shock MIL-STD-810D Cooling Nature convection Vibration 10..55..10 Hz, sweep15 minutes, amplitude 1.5 mm, max. 9 G X,Y, Z 2 hrs each axis Relative humidity operating and storage 20% to 95% RH Physical Dimensions 1.6 x 1 x 0.33 inches 41 x 25.8 x 8.5 mm Weight 20 g Base material None Case material Metal Deutschland: Schweiz: Inselkammerstraße 10 Gründenstrasse 82 D-82008 Unterhaching CH-8247 Flurlingen Tel.: 089 614 503-10 Tel.: 052 647 42 00 E-Mail: power@hy-line.de E-Mail: power@hy-line.ch Life Support Policy : HY-LINE does not authorize the use of any of its products for use in life support devices or systems without the express written approval of an officer of the Company. Life support systems are devices which support or sustain life, and whose failure to perform, when properly used in accordance with instructions for use provided in the labeli ng, can be reasonably expected to result in significant injury to the user. Rev: 02 / 2008 f All dimensions in inches (mm) Pin Pitch tolerance ±0.014 (0.35)