6 W DC-DC Converter P6P-Series
- Wide 4:1 input range
- -40...85 °C operation temperature range
- Isolation up to 3000 VDC
- Continuous short circuit protection
- Under voltage protection
- Efficiency up to 85 %
- DIL24 plastic case Model guide Add suffix “H” for 3 kV isolation voltage Page 1 of 5 Type Input voltage Input current Output voltage [VDC] Output current [mA] max. Efficiency [%] typ. Capacitive load (note 1) [µF] max. nominal [VDC] range [VDC] No load [mA] typ. Full load [mA] typ. Single output Dual output Deutschland: Schweiz: Inselkammerstraße 10 Hochstrasse 355 D-82008 Unterhaching CH-8200 Schaffhausen Tel.: 089 614 503-10 Tel.: 052 647 42 00 E-Mail: power@hy-line.de E-Mail: power@hy-line.ch
Input : Filter Pi Network Input reflected ripple current 20 mAp-p, typ. (see Fig. 1) Start up time @ Vin nominal & R-load 20 ms Under voltage shut down P6P24xxx P6P48xxx Typical values ! lock on 8.5 V, lock out 7 V lock on 16.5 V, lock out 14.5V Isolation: Rated voltage Input / output 60 sec. Standard. 1500 VDC Suffix “H”: 3000 VDC Resistance input to output 109 Ω Capacitance 1 nF, typ. Output: Voltage tolerance ± 2 %, max. Voltage balance @ dual outp. ± 2 %, max. Cross deviation @ 75 % load difference between outputs ± 5 %, max. Line voltage regulation ± 0.5 %, max. Load voltage regulation ± 1.2 %, max. Temperature coefficient ± 0.02 % / °C Ripple and noise (at 20 MHz BW) <80 mVp-p, (see fig 2) <100 mVp-p, only P6Pxx24D Over load protection 160 % of specified current Short circuit protection Continuous, automatic restart Transient recovery time @ 25 % load steps 300 µs, typ. Transient response deviation @ 25 % load steps ± 3 %, ± 5 % only P6Pxx3R3x Note: All parameters are specified at Ta 25 °C, nominal input voltage and full load unless otherwise specified! *1 Specified by nominal input voltage and constant resistive load Page 2 of 5 General: Switching frequency 330 kHz, typ. Safety Standart complay with IEC, EN, UL, cUL 60950-1 Reliability calc. MTBF MIL-HDBK-217 F @ 25 °C >800000 h Environmental: Operating ambient temperature range -40…85 °C , see SOA -40… 60 °C, without derating Storage temperature range -55…125 °C Case temperature max. 100 °C Humidity 95 %, max., not condensing Cooling Free air convection Physical : Dimensions 31.75 x 20.32 x 10.16 mm Weight 13 g Case material Black plastic, UL94V-0 rated Potting material Epoxy resin, UL94V-0 rated EMC in accordance with Radiated emissions EN55022 class A Conducted emissions EN55022 class A ESD IEC61000-4-2 perf. criteria A RS IEC61000-4-3 perf. criteria A EFT IEC61000-4-4 perf. criteria A Surge (see Fig. 3) IEC61000-4-5 perf. criteria A CS IEC61000-4-6 perf. criteria A PFMF IEC61000-4-8 perf. criteria A Absolute maximum ratings Input voltage P6P24xxx P6P48xxx Soldering temperature 260 °C for 10 s distance 1.5 mm from case Deutschland: Schweiz: Inselkammerstraße 10 Hochstrasse 355 D-82008 Unterhaching CH-8200 Schaffhausen Tel.: 089 614 503-10 Tel.: 052 647 42 00 E-Mail: power@hy-line.de E-Mail: power@hy-line.ch
Deutschland: Schweiz: Inselkammerstraße 10 Hochstrasse 355 D-82008 Unterhaching CH-8200 Schaffhausen Tel.: 089 614 503-10 Tel.: 052 647 42 00 E-Mail: power@hy-line.de E-Mail: power@hy-line.ch
Fig.1 Measure circuit for reflected input ripple current Fig.2 Measure circuit for output ripple and noise Fig.3 EMI filter circuit to comply IEC61000-4-5 performance criteria A Page 4 of 5 Deutschland: Schweiz: Inselkammerstraße 10 Hochstrasse 355 D-82008 Unterhaching CH-8200 Schaffhausen Tel.: 089 614 503-10 Tel.: 052 647 42 00 E-Mail: power@hy-line.de E-Mail: power@hy-line.ch 220 µF, 100 V + +Vin Full- load -Vout -Vin +Vout DC DC KY-Series Nippon Chemicon +Vin - Vin -Vout +Vout Load DC DC 1 µF ceramic 47 µF + +Vin Load -Vout -Vin +Vout 12 µH Measure point DC DC ESR <1 Ω @ 100 kHz
9 No pin Common Output
11 Not connected. -V Output 14 +V Output +V Output 16 -V Output Common Output 22 +V Input +V Input 23 +V Input +V Input Deutschland: Schweiz: Inselkammerstraße 10 Hochstrasse 355 D-82008 Unterhaching CH-8200 Schaffhausen Tel.: 089 614 503-10 Tel.: 052 647 42 00 E-Mail: power@hy-line.de E-Mail: power@hy-line.ch PHI-CON is a trademark of HY-LINE Holding GmbH. Only for professional use by professionals ! Not for resale or distribution to the general public in any way ! Read the instructions carefully before using! Life Support Policy: HY-LINE does not authorize the use of any of its products for use in life support devices or systems without the express wr itten approval of an officer of the Company. Life support systems are devices which support or sustain life, and whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in significant injury to the user. Rev: 01.17 f All units in mm 1. Pin tolerance ±0.05 mm 2. Pitch tolerance ±0.35 mm 3. Pin length tolerance ±0.35 mm 4. Case tolerance ±0.5 mm