DATASHEET SEARCH SITE | WWW.ALLDATASHEET.COM

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 5

Technical content

6 W DC-DC Converter P6L24xxCx-Series

HY-LINE Power Components Vertriebs GmbH HY-LINE AG Inselkammerstraße 10 Hochstrasse 355 D-82008 Unterhaching CH-8200 Schaffhausen Tel.: 089 614 503-10 Tel.: 052 647 42 00 E-Mail: power@hy-line.de E-Mail: info@hy-line.ch

  • Wide 4:1 input range
  • 1500 VDC isolation
  • Standard SIL 8 Pin package
  • Continuous short circuit protection
  • -40...85 °C operating temperature range Model guide Type Input voltage Input current Output voltage [VDC] Output current Efficiency @ full load Capacitive load (Cout) (see note 3) [µF] max. nominal [VDC] Range [VDC] no load max. [mA] full load max. [mA] min. load [mA] max. load [mA] [%] min. [%] typ. Single Output P6L243R3CS 24 9...36 12 245 3.3 0 1350 76 78 1800 P6L2405CS 24 9...36 12 315 5 0 1200 80 82 1000 P6L2409CS 24 9...36 16 315 5 0 667 82 84 470 P6L2412CS 24 9...36 16 315 12 0 500 84 86 470 P6L2415CS 24 9...36 16 315 15 0 400 85 87 220 P6L2424CS 24 9...36 16 315 24 0 250 83 85 100 Dual Output P6L2405CD 24 9...36 16 320 ±5 0 ±600 78 80 2 x 470 P6L2409CD 24 9...36 16 310 ±9 0 ±333 81 83 2 x 220 P6L2412CD 24 9...36 16 310 ±12 0 ±250 81 83 2 x 120 P6L2415CD 24 9...36 16 310 ±15 0 ±200 81 83 2 x 100 P6L2424CD 24 9...36 16 315 ±24 0 ±125 80 82 2 x 68 Specifications Input Under voltage protection Start up voltage Under voltage lockout P6L24xxCx ≤ 9 VDC ≥ 5.5 VDC Filter Capacitor Reflected ripple current 50 mAp-p, typ. (see Figure 1) Input surge voltage ≤ 50 VDC duration ≤ 1 s Remote control threshold (see Figure 5) ON state OFF state 3.5…12 V Or open input ≤1.2 V OFF state idle input current ≤10 mA Isolation input - output: Rated voltage (tested for 1 Minute) P6L24xxCS: 1600 VDC, at ≤ 1 mA P6L24xxCD: 1500 VDC, at ≤ 1 mA Resistance ≥ 109 Ω, measured @ 500 VDC Capacitance 1000 pF, typ. Output Voltage tolerance ≤ ± 3 %, load range 5…100 % Voltage load regulation ≤ ± 1.5 %, at 5 %...100 % load Voltage cross balance (dual outputs) ≤ ± 1.5 %, at balanced load Voltage cross deviation (dual outputs) ≤ ± 5 %, at 50 % load difference Line voltage regulation ≤ ± 1.5 %, over full Vin range Temperature coefficient ± 0.03 % / °C Transient recovery time ≤ 500 µs, at 25 % load steps Transient response deviation @ 25 % load steps ≤ 8 %, P6L243R3Cx, P6L2405Cx ≤ 5 % all others Short circuit protection Continuous, hiccup, auto restart Over current protection 110 %... 230 % of rated current Rippel & noise, BW 20MHz P6L24..CS ≤ 100 mVp-p (see Figure 2) P6L24..CD ≤ 150 mVp-p (see Figure 2) Product ordering information Series P6L Input voltage Output voltage Revision Output configuration PHI-CON 6 W 24 24 V 3R3 3.3 V C S Single 05 5 V D Dual 09 9 V 12 12 V 15 15 V 24 24 V Example: P6L2405CD Pout: 6 W, Vin: 24 V (9…36 V), Vout: ±5 V Page 1 of 5 General Safety standard EN 62368-1 Start up time 10 ms, typ at R-load Switching frequency 500 kHz, typ. Reliability calculated MTBF MIL-HDBK-217F @ 25 °C ≥ 1 Mio. h EMC characteristics CE EN 55032, CISPR 32 Class B (see Figure 4) RE EN 55032, CISPR 32 Class B (see Figure 4) ESD EN-, IEC 61000-4-2 Contact ± 4 kV perf. Criteria B RS EN-, IEC 61000-4-3 10V/m perf. Criteria A EFT EN-, IEC 61000-4-4 ± 2 kV perf. perf. Criteria B (see Figure 4) Surge EN-, IEC 61000-4-5 Line to line ± 2 kV perf. Criteria B (see Figure 4) CS EN-, IEC 61000-4-6 3 Vrms perf. Criteria A Environmental Operating ambient temperature P6L…CS -40 °C … 85 °C with derating P6L…CD -40 °C … 105 °C with derating Storage temperature -55 °C … 125 °C Storage humidity 5…95 %, non condensing Cooling Free air convection, ≥ 35 LFM Vibration X-, Y- and Z-axis 10…150 Hz, 5g, 0,75 mm Physical Dimensions 9.5 x 22 x 12 mm Weight 4.6 g Case material Plastic (UL94V-0 rated) Potting Material Epoxy (UL94V-0 rated) Absolute max. ratings Pin soldering temperature ≤ 300°C peak duration ≤ 10 s, ≥ 1.5mm body distance

HY-LINE Power Components Vertriebs GmbH HY-LINE AG Inselkammerstraße 10 Hochstrasse 355 D-82008 Unterhaching CH-8200 Schaffhausen Tel.: 089 614 503-10 Tel.: 052 647 42 00 E-Mail: power@hy-line.de E-Mail: info@hy-line.ch Note: 1. Min. load should not be less than 5 %, otherwise ripple maybe increased dramatically, If the product operates under min. load , it may not be guaranteed to meet all specifications listed. Operation under minimum load will not damage the converter. 2. The recommended unbalanced load of dual output converter should be ≤ 5 %. At load asymmetry ≥ 5 %, it may not be guaranteed to meet al l specifications listed. 3. Maximum capacitive load is tested at input voltage range and full load. 4. All specifications measured at Ta 25 °C, humidity < 75 %, nominal input voltage and rated output load unless otherwise specified. 5. It is not recommended to increase the output power capability by connecting two or more converters in parallel Figure 1 Measure circuit input reflected ripple current Figure 2 Measure circuit output ripple & noise voltage Figures 3 Typical application circuit The P6L series been tested according to the following recommended test circuit before leaving the factory (see Figures 3a & 3b). If you want to further decrease the input / output ripple, you can increase a capacitance values properly or choose capacitor s with low ESR, but the total capacitance of the filter capacitor must not exceed the maximum load capacitance value (see Model guide table). Figure 3a Figure 3b Page 2 of 5 Recommended peripheral components to figure 3a & 3b Vin type Cin Cout P6L24xxCS 100 µF, 50 V 22 µF P6L24xxCD 100 µF, 50 V 2 x 22 µF

HY-LINE Power Components Vertriebs GmbH HY-LINE AG Inselkammerstraße 10 Hochstrasse 355 D-82008 Unterhaching CH-8200 Schaffhausen Tel.: 089 614 503-10 Tel.: 052 647 42 00 E-Mail: power@hy-line.de E-Mail: info@hy-line.ch Figures 4a & b EFT and Surge Filter to meet EN-, IEC 61000-4-4 Class B and EN-, IEC 61000-4-5 Class B EMI-Filter to meet conducted- and radiated- emission EN 55032-, CISPR32- Class B Single output application Dual output application Recommended peripheral components to circuits in figures 4 a & b Type Fuse Time delay type Cin, C4 C1, C2 L LCM C3 CY Cout P6L24xxCS 2 A 330 µF, 100 V 10 µF, 100 V - 0.47 mH - 1 nF, 2 kV See table Figure 3 P6L24xxCD 2 A 330 µF, 100 V 10 µF, 100 V 10 µH 1.5 mH 10 µF, 50 V 1 nF, 2 kV Page 3 of 5

HY-LINE Power Components Vertriebs GmbH HY-LINE AG Inselkammerstraße 10 Hochstrasse 355 D-82008 Unterhaching CH-8200 Schaffhausen Tel.: 089 614 503-10 Tel.: 052 647 42 00 E-Mail: power@hy-line.de E-Mail: info@hy-line.ch Figure 5 Remote control application circuits Page 4 of 5

HY-LINE Power Components Vertriebs GmbH HY-LINE AG Inselkammerstraße 10 Hochstrasse 355 D-82008 Unterhaching CH-8200 Schaffhausen Tel.: 089 614 503-10 Tel.: 052 647 42 00 E-Mail: power@hy-line.de E-Mail: info@hy-line.ch Mechanical dimensions Page 5 of 5 Pin assignment Single Dual 1 - Vin - Vin 2 + Vin + Vin 3 Rem. Ctrl Rem. Ctrl

4 No pin No pin

5 N.C. N.C. 6 + Vout + Vout 7 - Vout/ 0V Common 8 N.C. - Vout Unit: mm Pin diameter tolerance: 0.1 mm General tolerances: 0.5 mm PHI-CON is a trademark of HY-LINE Holding GmbH. Only for professional use by professionals! Not for resale or distribution to the general public in any way! Read the instruc tions carefully before using! Life Support Policy: HY-LINE does not authorize the use of any of its products for use in life suppor t devices or systems without the express written approval of an officer of the Company. Life support systems are devices which support or sustain life, and whose failure to p erform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in significant injury to the user. Rev: 20211027 f