DATASHEET SEARCH SITE | WWW.ALLDATASHEET.COM

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 3

Technical content

6 W DC-DC Converter P6G-Series

HY-LINE Power Components Vertriebs GmbH HY-LINE AG Inselkammerstraße 10 Hochstrasse 355 D-82008 Unterhaching CH-8200 Schaffhausen Tel.: 089 614 503-10 Tel.: 052 647 42 00 E-Mail: power@hy-line.de E-Mail: info@hy-line.ch

  • 8 Pin SIL
  • Wide 4:1 input range
  • 1500 VDC and optional 3000 VDC isolation
  • Continuous short circuit protection
  • ON/OFF Remote control input Model guide Specifications Notes: 1. The maximum capacitive load is specified by minimal Vin and constant resistive load. 2. All specifications are typical at 25 °C, nominal input voltage and full load unless otherwise noted. Page 1 of 3 Type Input voltage Input current Output voltage [VDC] Output current Efficiency typ. [%] Capacitive load (see note1) [µF] max. nominal [VDC] range [VDC] no load [mA] typ. full load [mA] typ. [mA] max. [mA] min. Single Output P6G243R3S 24 9…36 6 260 3.3 0 1500 79 4700 P6G2405S 24 9…36 6 300 5.0 0 1200 84 2200 P6G2409S 24 9…36 6 290 9.0 0 665 86 1000 P6G2412S 24 9…36 6 290 12.0 0 500 87 470 P6G2415S 24 9…36 6 290 15.0 0 400 87 220 P6G2424S 24 9…36 6 290 24.0 0 250 87 100 P6G483R3S 48 18...75 6 130 3.3 0 1500 79 4700 P6G4805S 48 18...75 6 150 5.0 0 1200 83 2200 P6G4809S 48 18...75 6 145 9.0 0 665 85 1000 P6G4812S 48 18...75 6 145 12.0 0 500 87 470 P6G4815S 48 18...75 6 145 15.0 0 400 87 220 P6G4824S 48 18...75 6 145 24.0 0 250 87 100 Dual Output P6G2405D 24 9…36 6 300 ±5.0 0 ± 600 84 2 x 330 P6G2412D 24 9…36 6 290 ±12.0 0 ± 250 86 2 x 220 P6G2415D 24 9…36 6 290 ±15.0 0 ± 200 87 2 x 100 P6G4805D 48 18...75 6 150 ±5.0 0 ± 600 82 2 x 330 P6G4812D 48 18...75 6 145 ±12.0 0 ± 250 85 2 x 220 P6G4815D 48 18...75 6 145 ±15.0 0 ± 200 86 2 x 100 Input Filter Capacitor Input reflected ripple current P6G24xxx: 20 mAp-p, typ. P6G48xxx: 40 mAp-p, typ. (see Figure 1) ON / OFF remote controll pin 3 ON: open / high impedance OFF: 3.3 / 5 V via series resistor 1 kΩ (see Figure 3) Off state control current 2 ... 4 mA Off state current consumption 2.5 mA, typ. Isolation: I/O isolation voltage (tested for 60 s) P6Gxxxxx: 1500 VDC P6GxxxxxH: 3000 VDC Resistance ≥ 109 Ω Capacitance 50 pF, typ. Output Voltage tolerance ≥ ± 1 % Line regulation ≥ ± 0.2 % Load deviation ≥ ± 1 % Dual output cross deviation ± 5 % @ 75% load difference Short circuit protection Continuous, automatic restart Start up time @ Vin nom & R-load 30 ms, typ Ripple & noise (20 MHz BW) ≤ 125 mVp-p (see Figure 2) Temperature coefficient ± 0.02 % / °C Transient recovery time 250 µs, typ., at 25 % load change steps Transient responce deviation P6Gxx3R3x, P6Gxx5x: ≤ ± 5 % All others: ≤ ± 3 % at 25 % load change steps General Switching frequency 580 kHz, typ. Reliability calculated MTBF (MIl-HDBK-217F@ 25°C) 800 000 h Safety standard EN 60950-1, IEC 60950-1 EN 62368-1, IEC 62368-1 Safety approval UL 62368-1, cUL 62368-1 Environmental Operating ambient temperature -40 … 71 °C (see derating curve) Storage temperature -55 ... 125 °C Case temperature ≤ 100 °C Humidity Up to 95 %, non condensing Cooling, Free air convection 30…65 LFM Physical Dimensions 21.9 x 9.2 x 11.1 mm Weight 4.5 g Case material Black plastic, UL94V-0 rated Potting material Epoxy, UL94V-0 rated EMC Specifiations RE EN 55032 Class A (see Figure 4) CE EN 55032 Class A (see Figure 4) ESD IEC 61000-4-2 Pref. criteria A RS IEC 61000-4-3 Pref. criteria A EFT IEC 61000-4-4 Pref. criteria A (see Figure 4) Surge IEC 61000-4-5 Pref. criteria A (see Figure 4) CS IEC 61000-4-6 Pref. criteria A PFMF IEC 61000-4-8 Pref. criteria A Absolute maximum ratings P6G24xxx Vin: ≤ 50 VDC, duration ≤ 100 ms P6G48xxx Vin: ≤ 100 VDC, duration ≤ 100 ms Soldering Temperature ≤ 260 °C, duration ≤ 10 s, ≥ 1.5 mm package distance

HY-LINE Power Components Vertriebs GmbH HY-LINE AG Inselkammerstraße 10 Hochstrasse 355 D-82008 Unterhaching CH-8200 Schaffhausen Tel.: 089 614 503-10 Tel.: 052 647 42 00 E-Mail: power@hy-line.de E-Mail: info@hy-line.ch Figure 1 Measure circuit for input reflected ripple current Figure 2 Measure circuit for output ripple & noise (BW 20 MHz) Figure 3 Application circuit for remote control function Figure 4 Application circuit to meet EN 61000-4-4 performance. criteria A, EN 61000-4-5 performance. criteria A and EN 55032 class A Type TVS Cin KY-Serie Nippon Chemicon C1, C2 MLCC-Type L C3, C4 MLCC-Type MLCC-Type P6G24xxxx 75 V, 3 kW 330 µF, 100 V 10 µF, 35 V 12 µH 470 pF / 3 kV ---- P6G48xxxx 130 V, 3 kW 470 µF, 100 V 2.2 µF, 100 V 12 µH 1 nF / 3 kV 1 nF / 3 kV These components should be closed mounted as possible to the module. All leads should be minimized to decrease radiated noise . Page 2 of 3

HY-LINE Power Components Vertriebs GmbH HY-LINE AG Inselkammerstraße 10 Hochstrasse 355 D-82008 Unterhaching CH-8200 Schaffhausen Tel.: 089 614 503-10 Tel.: 052 647 42 00 E-Mail: power@hy-line.de E-Mail: info@hy-line.ch Part number structure Output power Series Input voltage Output voltage Outputs I/O Isolation P6 G 24 3R3 S -

6 Watt

24 9..36 V 3R3 3.3 V S single blank 1.5 kVDC 48 18..75 V 05 5 V D dual H 3 kVDC 09 9 V 12 12 V 15 15 V 24 24 V Mechanical dimensions Page 3 of 3 Pin assignment Pin P6GxxxxS P6GxxxxD P6GxxxxSH P6GxxxxDH 1 -V Input -V Input -V Input -V Input 2 +V Input +V Input +V Input +V Input

4 No pin No pin No pin No pin

5 N.C. N.C. No pin No pin 6 +V Output +V Output +V Output +V Output 7 -V Output Common -V Output Common 8 N.C. -V Output N.C. -V Output PHI-CON is a trademark of HY-LINE Holding GmbH. Only for professional use by professionals! Not for resale or distribution t o the general public in any way! Read the instructions carefully before using! Life Support Policy: HY-LINE does not authorize the use of any of its products for use in life support devices or systems without the express written approval of an officer of t he Company. Life support systems are devices which support or sustain life, and whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in significant injury to the user. Rev: 20210205 f Note: All dimensions in mm 1. Pin diameter tolerance: ± 0.05 mm 2. Pin pitch tolerance: ± 0.35 mm 3. Pin length tolerance: ± 0.35 mm 4. Pin to case tolerance: ± 0.5 mm 5. Stand off tolerance ± 0.1 mm