DATASHEET SEARCH SITE | WWW.ALLDATASHEET.COM
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 5
Technical content
6 W DC-DC Converter P6F-Series
Deutschland: Schweiz: Inselkammerstraße 10 Hochstrasse 355 D-82008 Unterhaching CH-8200 Schaffhausen Tel.: 089 614 503-10 Tel.: 052 647 42 00 E-Mail: power@hy-line.de E-Mail: power@hy-line.ch
- Wide 4:1 input range
- 1500 VDC isolation
- Standard package 1” x 1”
- Continuous short circuit and over voltage protection
- -40...85 °C operating temperature range Model guide Type Input voltage Input current Output voltage [VDC] Output current Efficiency @ full load Capacitive load (Cout) (see note 3) [µF] max. nominal [VDC] Range [VDC] no load max. [mA] full load max. [mA] min. load [mA] max. load [mA] [%] min. [%] typ. Single Output P6F243R3S 24 9...36 12 270 3.3 0 1500 77 79 1800 P6F2405S 24 9...36 12 310 5 0 1200 81 83 1000 P6F2409S 24 9...36 12 310 5 0 667 83 85 680 P6F2412S 24 9...36 12 310 12 0 500 85 87 470 P6F2415S 24 9...36 12 310 15 0 400 86 88 220 P6F24245S 24 9...36 12 310 24 0 250 86 88 100 P6F483R3S 48 18...75 8 135 3.3 0 1500 77 79 1800 P6F4805S 48 18...75 8 155 5 0 1200 81 83 1000 P6F4812S 48 18...75 8 155 12 0 500 85 87 470 P6F4815S 48 18...75 8 155 15 0 400 86 88 220 P6F4824S 48 18...75 8 155 24 0 250 86 88 100 Dual Output P6F2405D 24 9...36 12 310 ±5 0 ±600 81 83 2 x 470 P6F2412D 24 9...36 12 310 ±12 0 ±250 85 87 2 x 100 P6F2415D 24 9...36 12 310 ±15 0 ±200 86 88 2 x 100 P6F2424D 24 9...36 12 310 ±24 0 ±125 86 88 2 x 100 P6F4805D 48 18...75 8 155 ±5 0 ±600 81 83 2 x 470 P6F4812D 48 18...75 8 155 ±12 0 ±250 85 87 2 x 100 P6F4815D 48 18...75 8 155 ±15 0 ±200 86 88 2 x 100 Specifications Input Start up voltage P6F24xxx on @ ≤ 9 VD P6F48xxx on @ ≤ 18 VDC Under voltage lockout P6F24xxx off @ ≥ 5.5 VDC P6F48xxx off @ ≥ 12 VDC Filter π - type Reflected ripple current 20 mAp-p, typ. (see figure 1) Isolation input - output: Rated voltage (tested for 1 min.) 1500 VDC, at ≤ 1 mA Resistance > 109 Ω, measured @ 500 VDC Capacitance 1000 pF, typ. Output Voltage tolerance ± 3 %, max., load range 0~100 Voltage cross balance (dual outputs) ± 1.5 %, max. @ balanced load Voltage cross deviation (dual outputs) ± 5 %, max. @ 50 % load difference Input voltage regulation ± 1 %, max @ full Vin range Temperature coefficient ± 0.03 % / °C Transient recovery time ≤ 500 µs, @ 25 % load steps Transient response deviation @ 25 % load steps ≤ 8 %, @ P6Fxx3R3x, P6Fxx05x ≤ 5 % all others Short circuit protection Continuous, hiccup Short circuit restart Automatic Over current protection 110 % of rated current, min. 190 % of rated current, max. Rippel & noise, BW 20MHz 85 mVp-p, max. (see figure 2) Over voltage protection 110…160 % of rated Vout Page 1 of 5 General Start up time 10 ms, typ @ R-load Switching frequency 300 kHz, typ. Reliability calculated MTBF MIL-HDBK-217F @ 25 °C > 1 Mio. hours EMC characteristics Radiated emissions CISPR22 / EN55022 Class A Radiated emissions,(with Fig. 4) CISPR22 / EN55022 Class B Conducted emissions CISPR22 / EN55022 Class A Conducted emissions, (with Fig. 4) CISPR22 / EN55022 Class B ESD, (with Fig. 2) EN61000-4-2 Contact ± 4 kV perf. crit. B RS EN61000-4-3 10V/m perf. crit. A EFT (with Fig. 4) EN61000-4-4 ± 2 kV perf. crit. B Surge (with Fig. 4) EN61000-4-5 ± 2 kV perf. crit. B CS EN61000-4-6 3 Vrms perf. crit. A Voltage dips, short interruptions and voltage variations immunity EN61000-4-29 0..70 % perf. crit. B Environmental Operating ambient temperature -40 °C … 85 °C with derating Storage temperature -55 °C … 125 °C Storage humidity 5…95 %, non condensing Cooling Free air convection Vibration X-, Y- and Z-axis 10 G, 10..55 Hz, 30 minutes Physical Dimensions 25.40 x 25.40 x 11.7 mm Weight 14 g Case material Aluminium Alloy Potting Material Epoxy (UL94V-0 rated) Absolute max. ratings Pin soldering temperature 300°C for 10s, 1.5mm body distance Max. input voltage < 1 s P6F24xxx -0.7…50 VDC P6F48xxx -0.7…100 VDC
Deutschland: Schweiz: Inselkammerstraße 10 Hochstrasse 355 D-82008 Unterhaching CH-8200 Schaffhausen Tel.: 089 614 503-10 Tel.: 052 647 42 00 E-Mail: power@hy-line.de E-Mail: power@hy-line.ch - Input + Input DC DC + Vin - Vin + Vout - Vout Cout Cin - Input + Input DC DC + Vin - Vin + Vout - Vout Cout Cout Cin Figure 1 Measure circuit input reflected ripple current Figure 2 Measure circuit output ripple & noise voltage Figures 3 Typical application circuit The P6F series is been tested according to the following recommended test circuit before leaving the factory (see Figures 3a & 3b). If you want to further decrease the input / output ripple, you can increase a capacitance values properly or choose capacitors with low ESR, but the total capacitance of the filter capacitor must not exceed the maximum load capacitance value (see Model guide table). Figure 3a Figure 3b Page 2 of 5 Recommended peripheral components to figure 3a & 3b Cin Cout P6F24xxx 100 µF, 50 V 10 µF P6F48xxx 10...47 µF, 100 V 10 µF RL 10 µF 1 µF +Vin -Vout +Vout DC DC GND CH1 -Vin/GND RL RL 1 µF 1 µF 10 µF 10 µF +Vin -Vout -Vin/GND +Vout DC DC CH1 CH2 COM + 220 µF +Vin Load -Vout -Vin/GND +Vout 4.7 µH DC DC Measure point ESR <1 Ω @ 100 kHz
Deutschland: Schweiz: Inselkammerstraße 10 Hochstrasse 355 D-82008 Unterhaching CH-8200 Schaffhausen Tel.: 089 614 503-10 Tel.: 052 647 42 00 E-Mail: power@hy-line.de E-Mail: power@hy-line.ch Figures 4a & b EFT and Surge Filter to meet IEC/EN61000-4-4 Class B and IEC/EN61000-4-5 Class B EMI-Filter to meet conducted- and radiated- emission EN55022-, CISPR22- Class B Single output application Dual output application Recommended peripheral components to circuits in figures 4 a & b Type Fuse Time delay type MOV Type LCM Cin C1 C2 CY CX Cout P6F24xxS 2 A S20K30 4.7 mH 680 µF, 50 V 1 µF, 50 V 330 µF, 50 V 1 nF, 2 kV 4.7 µF, 50 V See model guide table P6F24xxD 2 A S20K30 4.7 mH 680 µF, 50 V 1 µF, 50 V 330 µF, 50 V 1 nF, 2 kV 4.7 µF, 50 V P6F48xxS 1 A S14K60 4.7 mH 680 µF, 100 V 1 µF, 100 V 330 µF, 100 V 1 nF, 2 kV 4.7 µF, 100 V P6F48xxD 1 A S14K60 4.7 mH 680 µF, 100 V 1 µF, 100 V 330 µF, 100 V 1 nF, 2 kV 4.7 µF, 100 V Note: 1. Min. load should not be less than 5 %, otherwise ripple maybe increased dramatically, If the product operates under min. load, it may not be guaranteed to meet all specifications listed. Operation under minimum load will not damage the converter. 2. The recommended unbalanced load of dual output converter should be ≤ 5 %. At load asymmetry ≥ 5 %, it may not be guaranteed to meet all specifications listed. 3. Maximum capacitive load is tested at input voltage range and full load. 4. All specifications measured at Ta 25 °C, humidity < 75 %, nominal input voltage and rated output load unless otherwise specified. 5. It is not recommended to increase the output power capability by connecting two or more converters in parallel. 6. The converters are not hot swappable Page 3 of 5 +Vin -Vin Load -Vout +Vout DC DC LCM EMI-Filter to meet class B EFT & Surge Filter to meet class B MOV CX Fuse CY CY Cout Load Cout Com Cin +Vin -Vin Load -Vout +Vout DC DC LCM EMI-Filter to meet class B EFT & Surge Filter to meet class B MOV CX Fuse CY CY Cout Cin
Deutschland: Schweiz: Inselkammerstraße 10 Hochstrasse 355 D-82008 Unterhaching CH-8200 Schaffhausen Tel.: 089 614 503-10 Tel.: 052 647 42 00 E-Mail: power@hy-line.de E-Mail: power@hy-line.ch Page 4 of 5
Deutschland: Schweiz: Inselkammerstraße 10 Hochstrasse 355 D-82008 Unterhaching CH-8200 Schaffhausen Tel.: 089 614 503-10 Tel.: 052 647 42 00 E-Mail: power@hy-line.de E-Mail: power@hy-line.ch Dimensions Page 5 of 5 Pin assignment Pin Single Dual 1 - Vin - Vin 2 + Vin + Vin 3 + Vout + Vout
4 No pin Common
PHI-CON is a trademark of HY-LINE Holding GmbH. Only for professional use by professionals ! Not for resale or distribution to the general public in any way ! Read the instructions carefully before using! Life Support Policy: HY-LINE does not authorize the use of any of its products for use in life support devices or systems without the express written approval of an officer of the Company. Life support systems are devices which support or sustain life, and whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in significant injury to the user. Rev: 20171010 f Unit: mm Pin diameter tolerance: 0.1 mm General tolerances: 0.5 mm