DATASHEET SEARCH SITE | WWW.ALLDATASHEET.COM

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 5

Technical content

6 W DC-DC Converter P6ExxxxCx-Series

HY-LINE Power Components Vertriebs GmbH HY-LINE AG Inselkammerstraße 10 Hochstrasse 355 D-82008 Unterhaching CH-8200 Schaffhausen Tel.: 089 614 503-10 Tel.: 052 647 42 00 E-Mail: power@hy-line.de E-Mail: info@hy-line.ch

  • Wide 2:1 input range
  • 1600 VDC isolation
  • Standard SIL 8 Pin package
  • Continuous short circuit protection
  • -40...105 °C operating temperature range Model guide Type Input voltage Input current Output voltage [VDC] Output current Efficiency @ full load Capacitive load (Cout) (see note 3) [µF] max. nominal [VDC] Range [VDC] no load max. [mA] full load max. [mA] min. load [mA] max. load [mA] [%] min. [%] typ. Single Output P6E123R3CS 12 9...18 18 500 3.3 0 1350 74 76 1800 P6E1205CS 12 9...18 18 640 5 0 1200 78 80 1000 P6E1209CS 12 9...18 18 640 5 0 667 80 82 470 P6E1212CS 12 9...18 18 640 12 0 500 82 84 470 P6E1215CS 12 9...18 18 640 15 0 400 82 84 220 P6E1224CS 12 9...18 18 640 24 0 250 82 84 100 P6E243R3CS 24 18...36 12 245 3.3 0 1350 76 78 1800 P6E2405CS 24 18...36 12 315 5 0 1200 80 82 1000 P6E2409CS 24 18...36 16 315 5 0 667 82 84 470 P6E2412CS 24 18...36 16 315 12 0 500 84 86 470 P6E2415CS 24 18...36 16 315 15 0 400 85 87 220 P6E2424CS 24 18...36 16 315 24 0 250 83 85 100 Specifications Input Under voltage protection Start up voltage Under voltage lockout P6E12xxCx ≤ 9 VDC ≥ 5.5 VDC P6E24xxCx ≤ 18 VDC ≥ 12 VDC Filter Capacitor Reflected ripple current 50 mAp-p, typ. (see Figure 1) Input surge voltage P6E12xxCS ≤ 25 VDC duration ≤ 1 s P6E24xxCS ≤ 50 VDC duration ≤ 1 s Remote control threshold (see Figure 5) ON state OFF state 3.5…12 V Or open input ≤1.2 V OFF state idle input current ≤10 mA Isolation input - output: Rated voltage (tested for 1 Minute) 1600 VDC, at ≤ 1 mA Resistance ≥ 109 Ω, measured @ 500 VDC Capacitance 1000 pF, typ. Output Voltage tolerance ≤ ± 2 %, load range 5…100 % Voltage load regulation ≤ ± 1.5 %, at 5 %...100 % load Input voltage regulation ≤ ± 1 %, over full Vin range Temperature coefficient ± 0.03 % / °C Transient recovery time ≤ 500 µs, at 25 % load steps Transient response deviation @ 25 % load steps ≤ 8 %, P6Exx3R3CS, P6Exx05CS ≤ 5 % all others Short circuit protection Continuous, hiccup, auto restart Over current protection 110…230 % of rated current Rippel & noise, BW 20MHz ≤ 100 mVp-p (see Figure 2) Product ordering information Series P6E Input voltage Output voltage Revision Output configuration PHI-CON 6 W 24 24 V 3R3 3.3 V C S Single 05 5 V 09 9 V 12 12 V 15 15 V 24 24 V Example: P6E2405CS Pout: 6 W, Vin: 24 V (18…36 V), Vout: 5 V Page 1 of 5 General Safety standard EN 62368-1 Start up time 10 ms, typ at R-load Switching frequency 500 kHz, typ. Reliability calculated MTBF MIL-HDBK-217F @ 25 °C ≥ 1 Mio. h EMC characteristics CE EN 55032, CISPR 32 Class B (see Figure 4) RE EN 55032, CISPR 32 Class B (see Figure 4) ESD EN-, IEC 61000-4-2 Contact ± 4 kV perf. Criteria B RS EN-, IEC 61000-4-3 10V/m perf. Criteria A EFT EN-, IEC 61000-4-4 ± 2 kV perf. perf. Criteria B (see Figure 4) Surge EN-, IEC 61000-4-5 Line to line ± 2 kV perf. Criteria B (see Figure 4) CS EN-, IEC 61000-4-6 3 Vrms perf. Criteria A Environmental Operating ambient temperature -40 °C … 105 °C with derating Storage temperature -55 °C … 125 °C Storage humidity 5…95 %, non condensing Cooling Free air convection, ≥ 35 LFM Vibration X-, Y- and Z-axis 10…150 Hz, 5 g, 0.75 mm Physical Dimensions 9.5 x 22 x 12 mm Weight 4.6 g Case material Plastic (UL94V-0 rated) Potting Material Epoxy (UL94V-0 rated) Absolute max. ratings Pin soldering temperature ≤ 300°C peak duration ≤ 10 s, ≥ 1.5mm body distance

HY-LINE Power Components Vertriebs GmbH HY-LINE AG Inselkammerstraße 10 Hochstrasse 355 D-82008 Unterhaching CH-8200 Schaffhausen Tel.: 089 614 503-10 Tel.: 052 647 42 00 E-Mail: power@hy-line.de E-Mail: info@hy-line.ch Note: 1. Min. load should not be less than 5 %, otherwise ripple maybe increased dramatically, If the product operates under min. load , it may not be guaranteed to meet all specifications listed. Operation under minimum load will not damage the converter. 2. The recommended unbalanced load of dual output converter should be ≤ 5 %. At load asymmetry ≥ 5 %, it may not be guaranteed to meet al l specifications listed. 3. Maximum capacitive load is tested at input voltage range and full load. 4. All specifications measured at Ta 25 °C, humidity < 75 %, nominal input voltage and rated output load unless otherwise specified. 5. It is not recommended to increase the output power capability by connecting two or more converters in parallel. Figure 1 Measure circuit input reflected ripple current Figure 2 Measure circuit output ripple & noise voltage Figures 3 Typical application circuit The P6E series been tested according to the following recommended test circuit before leaving the factory (see Figures 3a & 3b). If you want to further decrease the input / output ripple, you can increase a capacitance values properly or choose capacitor s with low ESR, but the total capacitance of the filter capacitor must not exceed the maximum load capacitance value (see Model guide table). Page 2 of 5 Recommended peripheral components to figure 3a & 3b Vin type Cin Cout P6E12xxCS 100 µF, 50 V 22 µF P6E24xxCS 100 µF, 100 V 22 µF

HY-LINE Power Components Vertriebs GmbH HY-LINE AG Inselkammerstraße 10 Hochstrasse 355 D-82008 Unterhaching CH-8200 Schaffhausen Tel.: 089 614 503-10 Tel.: 052 647 42 00 E-Mail: power@hy-line.de E-Mail: info@hy-line.ch Figure 4 EFT and Surge Filter to meet EN-, IEC 61000-4-4 Class B and EN-, IEC 61000-4-5 Class B EMI-Filter to meet conducted- and radiated- emission EN 55032-, CISPR32- Class B Figure 5 Remote control application circuits Page 3 of 5 Recommended peripheral components to circuits in figures 4 a & b Type Fuse Time delay type Cin, C4 C1, C2 L LCM CY Cout P6E12xxCS 2 A 330 µF, 100 V 10 µF, 100 V 10 µH 0.47 mH 1 nF, 2 kV See table Figure 3 P6E24xxCS 2 A 330 µF, 100 V 10 µF, 100 V 10 µH 0.47 mH 1 nF, 2 kV

HY-LINE Power Components Vertriebs GmbH HY-LINE AG Inselkammerstraße 10 Hochstrasse 355 D-82008 Unterhaching CH-8200 Schaffhausen Tel.: 089 614 503-10 Tel.: 052 647 42 00 E-Mail: power@hy-line.de E-Mail: info@hy-line.ch Page 4 of 5

HY-LINE Power Components Vertriebs GmbH HY-LINE AG Inselkammerstraße 10 Hochstrasse 355 D-82008 Unterhaching CH-8200 Schaffhausen Tel.: 089 614 503-10 Tel.: 052 647 42 00 E-Mail: power@hy-line.de E-Mail: info@hy-line.ch Mechanical dimensions Page 5 of 5 Pin assignment Single 1 - Vin 2 + Vin 3 Rem. Ctrl

4 No pin

5 N.C. 6 + Vout 7 - Vout/ 0V 8 N.C. Unit: mm Pin diameter tolerance: 0.1 mm General tolerances: 0.5 mm PHI-CON is a trademark of HY-LINE Holding GmbH. Only for professional use by professionals! Not for resale or distribution to the general public in any way! Read the instructions carefully before using! Life Support Policy: HY-LINE does not authorize the use of any of its products for use in life support devices or systems without the express written approval of an officer of the Company. Life sup port systems are devices which support or sustain life, and whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in significant in jury to the user. Rev: 20211027 f