6 W DC-DC Converter P6E-Series
HY-LINE Power Components Vertriebs GmbH HY-LINE AG Inselkammerstraße 10 Hochstrasse 355 D-82008 Unterhaching CH-8200 Schaffhausen Tel.: 089 614 503-10 Tel.: 052 647 42 00 E-Mail: power@hy-line.de E-Mail: info@hy-line.ch
- SIL 8 Pin
- Wide input range 2:1
- 1500 VDC isolation
- Optional 3000 VDC isolation
- Continuous short circuit protection
- Remote control input Model guide Type Input voltage Input current no load [mA] typ. Input current full load [mA] typ. Output voltage [VDC] Output current min. [mA] Output current max. [mA] Efficiency @ full load [%] typ. Capacitive load (see note 1) [µF] max. Nominal [VDC] Range [VDC] Single output P6E053R3SC 5 4.5…9 105 1145 3.3 0 1300 75 6600 P6E0505SC 5 4.5…9 105 1520 5.0 0 1200 79 3300 P6E0509SC 5 4.5…9 105 1445 9.0 0 667 83 2000 P6E0512SC 5 4.5…9 105 1430 12.0 0 500 84 1600 P6E0515SC 5 4.5…9 105 1430 15.0 0 400 84 1400 P6E0524SC 5 4.5…9 105 1430 24.0 0 250 84 680 P6E123R3SC 12 9…18 55 470 3.3 0 1300 76 6600 P6E1205SC 12 9…18 55 600 5.0 0 1200 83 3300 P6E1209SC 12 9…18 55 595 9.0 0 667 84 2000 P6E1212SC 12 9…18 55 590 12.0 0 500 85 1600 P6E1215SC 12 9…18 55 590 15.0 0 400 85 1400 P6E1224SC 12 9…18 55 580 24.0 0 250 86 680 P6E243R3SC 24 18…36 30 230 3.3 0 1300 78 6600 P6E2405SC 24 18…36 30 300 5.0 0 1200 83 3300 P6E2409SC 24 18…36 30 295 9.0 0 667 85 2000 P6E2412SC 24 18…36 30 295 12.0 0 500 85 1600 P6E2415SC 24 18…36 30 285 15.0 0 400 87 1400 P6E2424SC 24 18…36 30 285 24.0 0 250 87 680 P6E483R3SC 48 36...75 15 115 3.3 0 1300 76 6600 P6E4805SC 48 36...75 15 155 5.0 0 1200 80 3300 P6E4809SC 48 36...75 15 145 9.0 0 667 85 2000 P6E4812SC 48 36...75 15 150 12.0 0 500 84 1600 P6E4815SC 48 36...75 15 145 15.0 0 400 86 1400 P6E4824SC 48 36...75 15 150 24.0 0 250 84 680 Dual output P6E0505DC 5 4.5…9 105 1480 ±5.0 0 ±600 81 2 x 2000 P6E0512DC 5 4.5…9 105 1430 ±12.0 0 ±250 84 2 x 900 P6E0515DC 5 4.5…9 105 1430 ±15.0 0 ±200 84 2 x 660 P6E1205DC 12 9…18 55 610 ±5.0 0 ±600 82 2 x 2000 P6E1212DC 12 9…18 55 595 ±12.0 0 ±250 84 2 x 900 P6E1215DC 12 9…18 55 580 ±15.0 0 ±200 86 2 x 660 P6E2405DC 24 18…36 30 305 ±5.0 0 ±600 82 2 x 2000 P6E2412DC 24 18…36 30 300 ±12.0 0 ±250 84 2 x 900 P6E2415DC 24 18…36 30 300 ±15.0 0 ±200 84 2 x 660 P6E4805DC 48 36...75 15 150 ±5.0 0 ±600 82 2 x 2000 P6E4812DC 48 36...75 15 145 ±12.0 0 ±250 85 2 x 900 P6E4815DC 48 36...75 15 145 ±15.0 0 ±200 85 2 x 660 Part number structure Output power Series Input voltage Output voltage Outputs Isolation Remote control P6 E 05 3R3 S H C Input 12 9..18 V 05 5 V D dual H 3 kV 24 18..36 V 09 9 V Blank without remote control function 48 36..75 V 12 12 V 15 15 V 24 24 V Page 1 of 4
HY-LINE Power Components Vertriebs GmbH HY-LINE AG Inselkammerstraße 10 Hochstrasse 355 D-82008 Unterhaching CH-8200 Schaffhausen Tel.: 089 614 503-10 Tel.: 052 647 42 00 E-Mail: power@hy-line.de E-Mail: info@hy-line.ch Specifications Notes: 1. Maximum capacitive load is specified at minimal Vin and constant resistive load. 2. Free air convection is usually about 30…65 LFM but is not equal t o still air. 3. All specifications are typical at 25 °C, nominal input voltage and full load unless otherwise noted. Figure 1 Measure circuit Reflected input ripple current Input reflected current is measured through a source inductor and a source capacitor at nominal input voltage and full load. Page 2 of 4 Input Input reflected ripple current 30 mApp, typ. (see Figure 1) Filter Capacitors On / Off controll pin on: open off: 2...4 mA control current (via serial resistor 1 kΩ, see Figure 3) Standby current consumption 2.5 mA typ. Isolation: isolation voltage input / output (60 s)
1500 VDC
3000 VDC (Suffix “H”)
Resistance 109 Ω, min. Capacitance 50 pF, max. Output Voltage accuracy ± 1 % Ripple and noise (at 20 MHz BW) 75 mVp-p, max. (see Figure 2) Short circuit protection Continuous Short circuit restart Automatic Start up time 30 ms, typ. Line voltage regulation ± 0.2 % Load regulation ± 1 % (at 0…100 % load change) Dual output cross regulation at 75 % load difference ± 5 %, max. Temperature coefficient ± 0.02 % / °C Transient recovery time at 25 % load change steps 500 µs, typ. Transient response deviation at 25 % load change steps P6Exx3R3S ± 5 %, max. P6Exx05x ± 5 %, max. All others ± 3 %, max. General Switching frequency 100 kHz, min. Safety standards IEC-, EN-, UL-,ULc 60950-1 IEC-, EN-, UL-,ULc 62368-1 Reliability calculated MTBF (MIL-HDBK-217F, 25 °C) > 770000 h EMC specifications CE EN 55032 Class A RE EN 55032 Class A (see Figure 4) ESD EN-; IEC 61000-4-2 Perf. criteria A RS EN-; IEC 61000-4-3 Perf. criteria A EFT EN-; IEC 61000-4-4 Perf. criteria A (see Figure 4) Surge EN-; IEC 61000-4-5 Perf. criteria A (see Figure 4) CS EN-; IEC 61000-4-6 Perf. criteria A PFMF EN-; IEC 61000-4-8 Perf. criteria A Environmental Operating ambient temperature -40 … 65 °C Case operating temperature 105 °C, max. Storage temperature -55 ... 125 °C Derating See derating diagram Storage humidity Up to 95 %, non condensing Cooling Physical Dimensions SIP8 21.85 x 9.2 x 11.1 mm Weight 4.5 g Case material Non conductive plastic (UL94-V0 rated) Potting material Epoxy (UL94-V0 rated) Absolute maximum ratings Absolute max. voltage for 100 ms P6E05xxxx 15 VDC P6E12xxxx 36 VDC P6E24xxxx 50 VDC P6E48xxxx 100 VDC Pin soldering temperature ≤ 260 C° for ≤ 10 s, ≥ 1.5 mm distance from body 47 µF + +Vin Load -Vout -Vin/GND +Vout 12 µH Measure point DC DC ESR <1 Ω @ 100 kHz
HY-LINE Power Components Vertriebs GmbH HY-LINE AG Inselkammerstraße 10 Hochstrasse 355 D-82008 Unterhaching CH-8200 Schaffhausen Tel.: 089 614 503-10 Tel.: 052 647 42 00 E-Mail: power@hy-line.de E-Mail: info@hy-line.ch Figure 2 Measure circuit output ripple & noise voltage Use the following measurement circuit. The oscilloscope measurement bandwidth 20 MHz. Single output Dual output Figure 3 Application circuit for remote control function Figure 4 Application circuit EMI Filter for EN 55032 class A The filter components are used to help meet conducted emissions requirement for the modul e. These components should be closed mounted as possible to the module. All leads should be minimized to decrease radiated noise. BOM for Figure 4 Type Cin C1, C2 CY L P6E05xxxx 330 µF 22 µF, 25 V, MLCC 220 pF / 3 kV 10 µH P6E12xxxx 330 µF 10 µF, 50 V, MLCC 220 pF / 3 kV 10 µH P6E24xxxx 330 µF 10 µF, 50 V, MLCC 220 pF / 3 kV 10 µH P6E48xxxx 330 µF 2.2 µF, 100 V, MLCC 220 pF / 3 kV 10 µH Page 3 of 4 on off +Vin Load -Vout +Vout DC DC On/Off control input -Vin/GND Icontr. 2… 4 mA RL 10 µF + 0.1 µF +Vin -Vout +Vout DC DC GND CH1 -Vin/GND 0.1 µF 10 µF + RL RL 0.1 µF 10 µF + +Vin -Vout -Vin/GND +Vout DC DC CH1 CH2 COM Cin + +Vin -Vin/GND +Vin Load -Vout -Vin +Vout DC DC L Fuse EMI-Filter to meet class A EFT & Surge-Filter CY CY
HY-LINE Power Components Vertriebs GmbH HY-LINE AG Inselkammerstraße 10 Hochstrasse 355 D-82008 Unterhaching CH-8200 Schaffhausen Tel.: 089 614 503-10 Tel.: 052 647 42 00 E-Mail: power@hy-line.de E-Mail: info@hy-line.ch Mechanical dimensions Page 4 of 4 Pin assignment Pin Single Single with Rem.-Ctrl. Dual Dual with Rem.-Ctrl. 1 -V Input -V Input -V Input -V Input 2 +V Input +V Input +V Input +V Input 3 No Pin Remote contr. on/off Not connected Remote contr. on/off
5 No Pin Not connected Not connected Not connected
6 +V Output +V Output +V Output +V Output 7 -V Output -V Output Common Common
8 Not connected Not connected -V Output -V Output
PHI-CON is a trademark of HY-LINE Holding GmbH. Only for professional use by professionals! Not for resale or distribution to the general public in any way! Read th e instructions carefully before using! Life Support Policy: HY-LINE does not authorize the use of any of its products for use in life support devices or systems without the express written approval of an officer of the Company. Life support systems are dev ices which support or sustain life, and whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in significant injury to the user. Rev: 20200206 f All units in mm 1. Pin diameter tolerance ± 0.05 mm 2. Pin pitch tolerance ± 0.35 mm 3. Pin length tolerance ± 0.35 mm 4. Pin to case tolerance ± 0.5 mm 5. Stand off tolerance ± 0.1 mm