P6C053R3S HY-LINE | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 3

Technical content

6W DC-DC Converter P6C-Series

  • Wide 2:1 input range
  • Low input voltage range 4.5 to 9 V
  • Up to 3500 V DC isolation
  • MTBF >1.12 Mio. hours
  • Continuous short circuit protection Model guide Input current Type Input voltage range [VDC] No load [mA] Full load [mA] Output voltage [VDC] Output current min. / max. [mA] Efficiency typ. [%] Capacitor load max. (see note 3) [mA] Single output Dual output Suffix: “H” for 3.5 kVDC isolation voltage Specifications Page 1 of 3 Input Filter LC circuit Reflected ripple current 35 mAp-p, typ. Start up time 20 ms, typ. Isolation: Rated voltage (1 minute, input to output)

1500 VDC, Standard

3500 VDC, Suffix “H”

Ω Capacitance 500 pF, typ. Output Voltage tolerance ± 1 %, max. ± 2 %, max. @ 3.3 V types Dual outputs cross regulation (see note 1) ± 5 %, max. Ripple and noise at 20 MHz BW (see note 2) 60 mVp-p, max. Short circuit protection C ontinuous, automatic restart Current limiting ~150 %, typ. of full load Line voltage regulation ± 0.5 %, max. Load voltage regulation ± 0.5 %, max. ± 1.5 %, max.@ 3.3 V types Temperature coefficient ± 0.02 % / °C Transient recovery time (see note 4) 250 µs, typ. Transient response deviation (see note 4) 3 %, max. General Switching frequency 270 kHz, typ. Reliability calculated MTBF (MIL-HDBK-217F) 1.21 Mio. hours Safety in accordance with IEC 60950-1 EMC Radiated emmisions EN55022 ClassA Conducted emmisions (see note 5) EN55022 ClassA ESD IEC 61000-4-2 perf. crit. A RS IEC 61000-4-3 perf. crit. A EFT ( see note 6) IEC 61000-4-4 perf. crit. A Surge ( see note 6) IEC 61000-4-5 perf. crit. A CS IEC 61000-4-6 perf. crit. A PFMF IEC 61000-4-8 perf. crit. A Environmental Operating temperatur (ambient) -40 °C to +85 °C Case temperature 100 °C, max. Storage temperature -40 °C to +125 °C Derating None required Humidity Up to 95%, non-condensing Cooling Free air convection Physical Dimensions 31.75 x 20.32 x 10.16 mm Weight 17 g metal, standard Potting material Epoxy (UL94-V-0 rated) Case material Nickel coated copper Absolute maximum ratings Input voltage 0.1 s max. -0.7 V DC …15 V DC Lead soldering Temperature 260 °C for 10 s, distance from package 1.5 mm Deutschland: Schweiz: Inselkammerstraße 10 Gründenstrasse 82 D-82008 Unterhaching CH-8247 Flurlingen Tel.: 089 614 503-10 Tel.: 052 647 42 00 E-Mail: power@hy-line.de E-Mail: power@hy-line.ch

6W DC-DC Converter P6C-Series Note: 1. If one output load is 25 % to 100 % and the other output load is 100 %, than the output voltage drift rate will be max. ± 5 %. 2. Ripple and noise measured with a 1 µF ceramic capacitor. 3. Tested by nominal input voltage and constant resistor load. 4. Tested by normal Vin and 25 % load step change (75 % - 50 % - 25 % of Io). 5. It’s recommended to add C1 330 µF, C2 470 µF, L 1.8 µH on the input end to achieve EN55022 conducted Class A. 6. An external filter capacitor is required if the module has to meet IEC61000-4-4 and IEC61000-4-5. C1 330 µF, C2 470 µF, L 1.8 µH Measure circuit for input reflected ripple current Input reflected ripple current is measured after the input inductor Lin and the source capacitor Cin at nominal input and full load. Output Ripple & Noise Measurement Test The oscilloscope measurement bandwidth must be better than 20 MHz. EMI Filter Input filter components C1, C2, L are used to help meet the conducted emissions requirements of the module. These components should be mounted as close as possible to the module. All pins should be minimized to decrease radiated noise. Page 2 of 3 Deutschland: Schweiz: Inselkammerstraße 10 Gründenstrasse 82 D-82008 Unterhaching CH-8247 Flurlingen Tel.: 089 614 503-10 Tel.: 052 647 42 00 E-Mail: power@hy-line.de E-Mail: power@hy-line.ch +Vin -Vin Cin 100 µF ESR <1Ω @ 100kHz Measure point for current probe +Vout -Vout Resistive load 100 % DC DC Lin 12 µH +Vout Measure points for oscilloscope Resistive load Cout 1 µF -Vout DC/DC-Converter +Vin -Vin +Vout -Vout Load DC DC L 1.8 µH 330 µF 470 µF

6W DC-DC Converter P6C-Series Dimensions Pin connections Page 3 of 3 Pin Single Dual 2 -V Input -V Input 3 -V Input -V Input

9 Omitted Common

11 N.C. -V Output 14 +V Output +V Output 16 -V Output Common 22 +V Input +V Input 23 +V Input +V Input Deutschland: Schweiz: Inselkammerstraße 10 Gründenstrasse 82 D-82008 Unterhaching CH-8247 Flurlingen Tel.: 089 614 503-10 Tel.: 052 647 42 00 E-Mail: power@hy-line.de E-Mail: power@hy-line.ch PHI-CON is a trademark of HY-LINE power components. Only for professional use by professionals! Not for resale or di stribution to the general public in any way! Read the instructi ons carefully before using! Life Support Policy: HY-LINE does not authorize the use of any of its produc ts for use in life support devices or systems without the express written approval of an officer of the Company. Life support systems are devices whic h support or sustain life, and whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonabl y expected to result in significant injury to the user. Rev: 02.14 f