6W DC-DC Converter P6B-Series
- Wide 4:1 input range
- -40...+85°C operatio n temperature range
- Isolation up to 3500 V DC
- MTBF > 1.12 MHours
- Continuous short circuit protection
- Efficiency up to 84% Model guide Add suffix “H” for 3.5 kV isolation voltage Add suffix “P” for plastic case Page 1 of 4 Input current Type Input voltage range [VDC] No-load [mA] Full-load [mA] Output voltage [VDC] Output current [mA] Efficiency typ. [%] Capacitive load (*1) [µF] Single output Dual output Deutschland: Schweiz: Inselkammerstraße 10 Gründenstrasse 82 D-82008 Unterhaching CH-8247 Flurlingen Tel.: 089 614 503-10 Tel.: 052 647 42 00 E-Mail: power@hy-line.de E-Mail: power@hy-line.ch
6W DC-DC Converter P6B-Series Specifications Input : Filter Pi Network Input reflected ripple current 35 mAp-p (*2) Isolation: Rated voltage Input / output 3 sec. Standard. 1500 VDC Suffix “H”: 3500 VDC Input or output to case 3 sec. 1000 V DC Resistance input to output 10 Ω Capacitance 500 pF, typ. Output: Voltage accuracy ± 1 % Line voltage regulation ± 0.5 %, max. Load voltage regulation ± 0.5 %, max. P6Bxx3R3x: 1.5 %, max. Temperature coefficient ± 0.02 % / °C Ripple and noise (at 20 MHz BW) 60 mVp-p, max. (*3) Short circuit protection C ontinuous, automatic restart General: Switching frequency 270 kHz, typ. Safety in accordance with IEC 60950-1 Reliability calc. MTBF 1.12 Mio. h, MIL-HDBK-217 F EMI filter circuit Test circuit for reflected input ripple current Test circuit for output ripple and noise Page 2 of 4 Environmental: Operating temperature -40…+85 °C ambient Storage temperature -40…+125 °C Case temperature max. 100 °C Derating see diagram Humidity 95 %, max., not condensing Cooling Free air convection Physical : Dimensions 31.75 x 20.32 x 10.16 mm Weight Metal 17 g, Plastic 14 g Case material Nickel coated copper Suffix “P”: Plastic Potting material UL94V-0 rated epoxy resin EMC in accordance with Radiated emissions EN55022 class A Conducted emissions EN55022 class A (*4) ESD IEC61000-4-2 perf. criteria A RS IEC61000-4-3 perf. criteria A EFT IEC61000-4-4 perf. criteria A Surge (*5) IEC61000-4-5 perf. criteria A CS IEC61000-4-6 perf. criteria A PFMF IEC61000-4-8 perf. criteria A Absolute maximum ratings Input voltage P6B24xxx P6B48xxx Soldering temperature 260 °C for 10 s distance 1.5 mm from case Deutschland: Schweiz: Inselkammerstraße 10 Gründenstrasse 82 D-82008 Unterhaching CH-8247 Flurlingen Tel.: 089 614 503-10 Tel.: 052 647 42 00 E-Mail: power@hy-line.de E-Mail: power@hy-line.ch + Vin L 12 µH C1 C2 68 µF 33 µF Load ESR <1 Ω at 100 kHz - Vin oscilloscope current probe + Vin 4.7µH Measure point 47 µF Load ESR <1 Ω at 100 kHz - Vin +Vout Measure points for oscilloscope Resistive load Cout 1 µF -Vout Note: All specifications at Ta 25 °C, nominal input voltage and full load unless otherwise specified! *1 Test by nominal input voltage and constant resistor load *2 Measured input reflected ripple current with a simulated source inductance of 12 µH *3 Typical value at nominal input voltage, full load and output ceramic chip capacitor 1 µF *4 It is recommended to add C1, C2 and L on input and to achieve EN 55022 conducted class A, see “EMI filter circuit” *5 Only with external input capacitor 220 µF, 100 V, Nippon Chemicon, KY series
6W DC-DC Converter P6B-Series Page 3 of 4 Deutschland: Schweiz: Inselkammerstraße 10 Gründenstrasse 82 D-82008 Unterhaching CH-8247 Flurlingen Tel.: 089 614 503-10 Tel.: 052 647 42 00 E-Mail: power@hy-line.de E-Mail: power@hy-line.ch
6W DC-DC Converter P6B-Series Dimensions (metal case) Pin connections Pin Isolation 1.5 / 3.5 kVDC Single Dual 2 -V Input -V Input 3 -V Input -V Input
9 Omitted Common
11 N.C. -V Output 14 +V Output +V Output 16 -V Output Common 22 +V Input +V Input 23 +V Input +V Input Page 4 of 4 Deutschland: Schweiz: Inselkammerstraße 10 Gründenstrasse 82 D-82008 Unterhaching CH-8247 Flurlingen Tel.: 089 614 503-10 Tel.: 052 647 42 00 E-Mail: power@hy-line.de E-Mail: power@hy-line.ch PHI-CON is a trademark of HY-LINE Holding GmbH. Only for professional use by professionals! Not for resale or di stribution to the general public in any way! Read the instructi ons carefully before using! Life Support Policy: HY-LINE does not authorize the use of any of its produc ts for use in life support devices or systems without the express written approval of an officer of the Company. Life support systems are devices whic h support or sustain life, and whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonabl y expected to result in significant injury to the user. Rev: 01.15 f