DATASHEET SEARCH SITE | WWW.ALLDATASHEET.COM
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 4
Technical content
60 W DC-DC Converter P60A-Series
Deutschland: Schweiz: Inselkammerstraße 10 Hochstrasse 355 D-82008 Unterhaching CH-8200 Schaffhausen Tel.: 089 614 503-10 Tel.: 052 647 42 00 E-Mail: power@hy-line.de E-Mail: power@hy-line.ch
- Wide 2:1 input range
- Efficiency up to 91 %
- Adjustable output voltage
- On/Off remote control
- 1600 VDC isolation
- Continuous short circuit protection
- Over current protection
- Over voltage protection
- Over temperature protection
- Soft start function
- Standard package 2” x 2” x 0.4”
- -40...85 °C operating temperature range
- Integrated EMC filter EN 55032 Class A Model guide Type Input voltage Input current Output voltage [VDC] Output current Efficiency [%] Output capacitor load [µF] max. Nominal [VDC] Range [VDC] no load [mA] typ. full load [mA] typ. [mA] min. [A] max P60A243R3S 24 18...36 80 2150 3.3 0 14 91 36000 P60A2405S 24 18...36 100 2760 5.0 0 12 91 20400 P60A2412S 24 18...36 40 2795 12.0 0 5 90 3550 P60A2415S 24 18...36 40 2795 15.0 0 4 90 2300 P60A483R3S 48 36...75 50 1075 3.3 0 14 91 36000 P60A4805S 48 36...75 60 1390 5.0 0 12 91 20400 P60A4812S 48 36...75 40 1395 12.0 0 5 91 3550 P60A4815S 48 36...75 40 1395 15.0 0 4 91 2300 Specifications Part number structure Output power Series Input voltage Output voltage Outputs Case P60 A 24 05 S K 60 Watt 24 18..36 V 3R3 3.3 V S single Blank Without heat sink 48 36..75 V 05 5 V K With heat sink 12 12 V 15 15 V Note: 1. The maximum capacitive load is specified at minimal input voltage and constant resistive load. 2. All specifications are typical at 25 °C, nominal input voltage and full load unless otherwise noted. Page 1 of 4 General Switching frequency 270 kHz, typ. Safety standard EN 60950-1, IEC 60950-1 Reliability calculated MBTF >110000 h EMC characteristics Radiated emissions EN 55032 Class A Conducted emissions EN 55032 Class A ESD EN 61000-4-2 pref criteria A RS EN 61000-4-3 pref criteria A EFT (See fig. 5) EN 61000-4-4 pref criteria A Surge (See fig. 5) EN 61000-4-5 pref criteria A CS EN 61000-4-6 pref criteria A PFMF EN 61000-4-8 pref criteria A Environmental Operating temperatur (ambient) -40 … 85 °C (see SOA diagram) Case temperature 110 °C, max. Storage temperature -40 … 125 °C Over temperature protection Tc 110 °C, typ Cooling Free air convection, 30..65 LFM Thermal impedance Without heat sink 10.5 K/W With heat sink 8.4 K/W Storage humidity 95 %, non condensing Physical Dimensions standard 50.8 x 50.8 x 10.16 mm Dimensions heat sink version 50.8 x 50.8 x 16.3 mm Weight Standard version: 87 g Heat sink version: 100 g Case material Copper nickel plated Potting Material Epoxy (UL94V-0 rated) Absolute max. ratings Max. input voltage for ≤0.1 s P60A24xxS: 50 VDC P60A48xxS: 100 VDC Pin soldering temperature ≥1.5 mm distance from body ≤ 260 °C for ≤ 10 s, ≥1.5 mm distance from body Input Start up voltage P60A24xxx: 17.8 VDC, typ. P60A48xxx: 33.5 VDC, typ. Under voltage lockout P60A24xxx: 16 VDC, typ. P60A48xxx: 30.5 VDC, typ. Filter π - type Reflected ripple current 20 mAp-p, typ. (See fig. 1) Remote control threshold (see figure 3) On state: 3… 12 VDC or open input Off state: 0…1.2 VDC Idle current, Rem. Ctrl. Off state 5 mA, typ. Isolation: Rated voltage input / output, input or output to case
1600 VDC
Resistance 109 Ω, min. Capacitance 2000 pF, typ. Output Voltage accuracy ± 1 % Output voltage trim range ± 10 % Line regulation ± 0.5 % Load regulation ± 0.5 % @ 0 %...100 % load Temperature coefficient ± 0.02 % / °C Ripple and noise P60Axx3R3S, -05S: ≤75 mVp-p P60Axx12S, -15S: ≤100 mVp-p Over voltage protection (Z-diode) P60Axx3R3x: 3.9 VDC P60Axx05x: 6.2 VDC P60Axx12x: 15 VDC P60Axx15x: 18 VDC Transient recovery time 250 µs, typ, @ 25 % load change steps Transient response deviation ≤3 % @ 25 % load change steps Short circuit protection Continuous, hiccup, automatic restart Over current protection 135 % of full load, typ. Start up time 20 ms, typ. @ R-load, nom. Vin
Deutschland: Schweiz: Inselkammerstraße 10 Hochstrasse 355 D-82008 Unterhaching CH-8200 Schaffhausen Tel.: 089 614 503-10 Tel.: 052 647 42 00 E-Mail: power@hy-line.de E-Mail: power@hy-line.ch Figure 1 Measure circuit for reflected input ripple current. Figure 2 Measure circuit for output ripple & noise. Figure 3 Application circuit remote control. Figure 4 Application circuit output voltage trimming. Figure 5 Application circuit to meet IEC 61000-4-4 Class A and IEC 61000-4-5 Class A Page 2 of 4 47 µF + +Vin Load -Vout -Vin/GND +Vout 12 µH Measure point DC DC ESR <1 Ω @ 100 kHz RL 1 µF +Vin -Vout +Vout DC DC GND CH1 -Vin/GND +Vin -Vin/GND Ctrl 3 +Vin 1 Load -Vout +Vout DC DC Remote control input on: 3 V…≤12 V or open input off: 0…1.2 V -Vin/GND 2 5 +sense Load 7 -Vout 6 +Vout DC DC
8 Trim
-Vin/GND +Vin 4 -sense The maximum output range is 10 % inclusive of remote sense and trim. If remote sense is not being used, the +SENSE should be connected to it is corresponding +OUTPUT and likewise the -SENSE should be connected to its corresponding -OUTPUT. 10 µF + 1 µF MLCC +Vin - Vin - Vout +Vout Load DC DC EFT & Surge-Filter 10 µF 220 µF 100 V ESR <1Ω + E.g. Nippon Chemicon KY-Series Filter components to meet EN 55032 Class A are integrated in the converter. The input capacitor 220 µF is used as suppressor for fast transient and surge pulse. All other capacitors are for further ripple and noise reduction.
Deutschland: Schweiz: Inselkammerstraße 10 Hochstrasse 355 D-82008 Unterhaching CH-8200 Schaffhausen Tel.: 089 614 503-10 Tel.: 052 647 42 00 E-Mail: power@hy-line.de E-Mail: power@hy-line.ch Page 3 of 4
Deutschland: Schweiz: Inselkammerstraße 10 Hochstrasse 355 D-82008 Unterhaching CH-8200 Schaffhausen Tel.: 089 614 503-10 Tel.: 052 647 42 00 E-Mail: power@hy-line.de E-Mail: power@hy-line.ch Without heat sink With heat sink Mechanical dimensions Standard version Heat sink version Page 4 of 4 Pin Assignment Pin Single output Dual output 1 + Vin + Vin 2 - Vin - Vin
3 Rem ctrl Rem ctrl
8 Trim Trim
PHI-CON is a trademark of HY-LINE Holding GmbH. Only for professional use by professionals! Not for resale or distribution to the general public in any way! Read the instructions carefully before using! Life Support Policy: HY-LINE does not authorize the use of any of its products for use in life support devices or systems without the express written approval of an officer of the Company. Li fe support systems are devices which support or sustain life, and whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in significant injury to the user. Rev: 20180919 f Note: All dimensions are in mm 1. Pin diameter tolerance ± 0.05 mm 2. Pin pitch tolerance ± 0.35 3. Pin length tolerance ± 0.35 4. Case tolerance ± 0.5