40 W DC-DC Converter P40B-Series

Deutschland: Schweiz: Inselkammerstraße 10 Hochstrasse 355 D-82008 Unterhaching CH-8200 Schaffhausen Tel.: 089 614 503-10 Tel.: 052 647 42 00 E-Mail: power@hy-line.de E-Mail: power@hy-line.ch

  • Wide 4:1 input range
  • Efficiency up to 92 %
  • Adjustable output voltage
  • On/Off remote control
  • 1600 VDC isolation
  • Continuous short circuit protection
  • Over voltage protection
  • Over temperature protection
  • Standard package 2” x 2” x 0.4”
  • -40...85°C operating temperature range
  • Soft start function Model guide Type Input voltage Input current Output voltage [VDC] Output current max. [mA] Ripple & noise (see fig. 2) max. [mVp-p] Outp. over voltage protection [VDC] Efficiency @ full load typ [%] Output capacitor load [µF] max. Nominal [VDC] Range [VDC] no load typ. [mA] full load typ. [mA] Single output P40B2412S 24 9...36 50 1920 12.0 3350 75 15 90 2300 P40B2415S 24 9...36 50 1920 15.0 2650 75 18 90 1500 P40B4812S 48 18...75 30 960 12.0 3350 75 15 90 2300 P40B4815S 48 18...75 30 950 15.0 2650 75 18 91 1500 Dual output P40B2412D 24 9...36 60 1940 ±12.0 ±1650 150 ±15 89 2 x 1200 P40B2415D 24 9...36 60 1940 ±15.0 ±1350 150 ±18 89 2 x 750 P40B4812D 48 18...75 30 960 ±12.0 ±1650 150 ±15 90 2 x 1200 P40B4815D 48 18...75 30 960 ±15.0 ±1350 150 ±18 90 2 x 750 Ordering information: Add suffix “K” for heat sink version, E.G.: P40B2405SK Specifications Page 1 of 5 General Switching frequency 270 kHz, typ. Safety standard in accordance with IEC, EN 60950-1 Reliability Calculated MBTF >150000 h EMC characteristics Radiated emissions EN55032 Class A Conducted emissions EN55032 Class A ESD EN61000-4-2 pref criteria A RS EN61000-4-3 pref criteria A EFT EN61000-4-4 pref criteria A Surge EN61000-4-5 pref criteria A CS EN61000-4-6 pref criteria A PFMF EN61000-4-8 pref criteria A Environmental Operating temperatur (ambient) -40 … 85 °C (see SOA diagram) Case temperature 105 °C, max. Storage temperature -40 … 125 °C Over temperature protection Tc 110 °C, typ Cooling Free air convection Thermal impedance Without heat sink 10.8 K/W With heat sink 8.8 K/W Storage humidity 95 %, non condensing Physical Dimensions 50.8 x 50.8 x 10.16 mm Weight Standard version: 87 g Heat sink version: 100 g Case material Nickel coated brass Potting Material Epoxy (UL94V-0 rated) Absolute max. ratings Pin soldering temperature 1.5 mm distance from body 260°C for 10 sec Max. input voltage for 0.1s P40B24xxx 50 VDC P40B48xxx 100 VDC Input Start up voltage P24xxx: 8.6 VDC, typ. P48xxx: 17.8 VDC, typ. Under voltage lockout P24xxx: 7.9 VDC, typ. P48xxx: 16 VDC, typ. Filter π - type Reflected ripple current 20 mAp-p, typ. (See fig. 1) Remote control levels On 3 … 12 VDC or open input Off 0 … 1.2 VDC (see figure 3) Off state input idle current 5 mA, typ. Isolation: Rated voltage input / output, input or output to case

1600 VDC

Resistance 109 Ω Capacitance 2500 pF, typ. Output Voltage accuracy ± 1 % Output voltage trim range ± 10 % Voltage cross balance (dual outputs) ±5 % @ 75 % load difference Line voltage regulation ± 0.5 % Load voltage regulation single Load voltage regulation dual Temperature coefficient ± 0.02 % / °C Transient recovery time 250 µs, typ, @ 25 % load change steps Transient response deviation ≤3 % @ 25 % load change steps Short circuit protection Continuous, hiccup Over load protection 130 % of full load, typ. Short circuit restart Automatic Over voltage protection (Z-diode) P40Bxx3R3x P40Bxx05x P40Bxx12x P40Bxx15x

3.9 VDC

6.2 VDC

12 VDC

15 VDC

Start up time 25 ms, typ. @ R-load, nom. Vin

Deutschland: Schweiz: Inselkammerstraße 10 Hochstrasse 355 D-82008 Unterhaching CH-8200 Schaffhausen Tel.: 089 614 503-10 Tel.: 052 647 42 00 E-Mail: power@hy-line.de E-Mail: power@hy-line.ch Figure 1 Measure circuit for reflected input ripple current. Figure 2 Measure circuit for output ripple & noise. Single output Dual output Figure 3 Application circuit remote control Figure 4 Application circuit output voltage trimming Single output Dual output Page 2 of 5 47 µF + +Vin Load -Vout -Vin/GND +Vout 12 µH Measure point DC DC ESR <1 Ω @ 100 kHz RL 1 µF +Vin -Vout +Vout DC DC GND CH1 -Vin/GND RL RL 1 µF 1 µF +Vin -Vout -Vin/GND +Vout DC DC CH1 CH2 COM +Vin -Vin/GND Ctrl 3 +Vin 1 Load -Vout +Vout DC DC Remote control input on: 3 V…≤12 V or open input off: 0…1.2 V -Vin/GND 2 Load 7 -Vout 6 +Vout DC DC

8 Trim

-Vin +Vin Load 7 -Vout 4 +Vout DC DC -Vin +Vin

5 Com

6 Com

Deutschland: Schweiz: Inselkammerstraße 10 Hochstrasse 355 D-82008 Unterhaching CH-8200 Schaffhausen Tel.: 089 614 503-10 Tel.: 052 647 42 00 E-Mail: power@hy-line.de E-Mail: power@hy-line.ch For the Single output: Maximum output deviation is 10 % inclusive of remote sense and trim. If remote sense is not being used, the + SENSE should be connected to it is corresponding +OUTPUT and likewise the - SENSE should be connected to its corresponding -OUTPUT. Figure 5 Application circuit to meet EMI EN55032 ClassA, EFT IEC61000-4-4 perf. crit. A & Surge IEC61000-4-5 perf. crit. A Single output Dual output Note: 1. The maximum capacitive load is specified at minimal input voltage and constant resistive load. 2. With input filter circuit to meet of conducted emissions EN55032 class A. (See figure 5) 3. An external input blocking capacitor is required if the converter has to meet IEC61000-4-5. Suggested capacitor type: KY-series, 220 µF, 100 V, Nippon Chemicon. (See figure 5) 4. Not usable for parallel output operation. Page 3 of 5 BOM to Figure 5 Cin C1 L C2 C3 P40B-24xxxxx 220 µF, 100 V, KY-Series, nippon chemicon 100 µF, 100 V 12 µH 1 nF, 2 kV 1 nF, 2 kV P40B-48xxxxx 220 µF, 100 V, KY-Series, nippon chemicon 100 µF, 100 V 12 µH 1 nF, 2 kV 1 nF, 2 kV +Vin - Vin +Vin Load -Vout -Vin +Vout DC DC L EMI-Filter to meet class A EFT & Surge- Filter Cin +Vin - Vin +Vin Load -Vout -Vin +Vout DC DC L EMI-Filter to meet class A EFT & Surge- Filter Cin COM Load

Deutschland: Schweiz: Inselkammerstraße 10 Hochstrasse 355 D-82008 Unterhaching CH-8200 Schaffhausen Tel.: 089 614 503-10 Tel.: 052 647 42 00 E-Mail: power@hy-line.de E-Mail: power@hy-line.ch Page 4 of 5

Deutschland: Schweiz: Inselkammerstraße 10 Hochstrasse 355 D-82008 Unterhaching CH-8200 Schaffhausen Tel.: 089 614 503-10 Tel.: 052 647 42 00 E-Mail: power@hy-line.de E-Mail: power@hy-line.ch Dimensions Dimensions Standard version Heat sink version Page 5 of 5 Pin Assignment Pin Single output Dual output 1 + Vin + Vin 2 - Vin - Vin

3 Rem ctrl Rem ctrl

8 Trim Trim

PHI-CON is a trademark of HY-LINE Holding GmbH. Only for professional use by professionals ! Not for resale or distribution to the general public in any way ! Read the instructions carefully before using! Life Support Policy: HY-LINE does not authorize the use of any of its products for use in life support devices or systems without the express written approval of an officer of the Company. Life support systems are devices which support or sustain life, and whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in significant injury to the user. Rev: 20180528 f Note: All dimensions are in mm 1. Pin diameter tolerance ± 0.05 mm 2. Pin pitch tolerance ± 0.35 3. Pin length tolerance ± 0.35 4. Case tolerance ± 0.5