40W DC-DC Converter P40A-Series
- Offer single, dual and triple output
- 40 W Output power
- 2:1 Wide input voltage range
- International safety standard approval
- Six-Sided continuous shield
- High efficiency up to 90%
- Standard 2" X 2" X 0.4" package
- Fixed switching frequency Model selection guide Input Output 1 Output 2 (or Dual Output) Typ nominal voltage [VDC] current full load [mA] voltage [VDC] current [A] capacitor load max. [µF] voltage [VDC] current [A] capacitor load max. [µF] Efficiency typ. [%] Output ripple & Noise [mVp-p] Single output P40A24S3P3 18-36 1325 3.3 8.0 21000 87 50 P40A24S05 18-36 1961 5.0 8.0 13600 89 50 P40A24S12 18-36 2048 12.0 3.3 2360 88 75 P40A24S15 18-36 1985 15.0 2.6 1510 89 75 P40A48S3P3 36-75 655 3.3 8.0 21000 88 50 P40A48S05 36-75 969 5.0 8.0 13600 90 50 P40A48S12 36-75 1000 12.0 3.3 2360 89 75 P40A48S15 36-75 992 15.0 2.6 1510 89 75 Dual output P40A24D3305 18-36 1729 3.3 4.0 11000 5.0 4.0 6800 84 100 @1µF P40A48D3305 36-75 854 3.3 4.0 11000 5.0 4.0 6800 85 100 @1µF Triple output P40A24T3312 18-36 1512 3.3 6.0 13000 ±12.0 ±0.4 2 x 330 85 75 P40A24T3315 18-36 1481 3.3 6.0 13000 ±15.0 ±0.3 2 x 110 85 75 P40A24T0512 18-36 1989 5.0 6.0 6800 ±12.0 ±0.4 2 x 330 87 75 P40A24T0515 18-36 1958 5.0 6.0 6800 ±15.0 ±0.3 2 x 110 87 75 P40A48T3312 36-75 747 3.3 6.0 13000 ±12.0 ±0.4 2 x 330 86 75 P40A48T3315 36-75 732 3.3 6.0 13000 ±15.0 ±0.3 2 x 110 86 75 P40A48T0512 36-75 982 5.0 6.0 6800 ±12.0 ±0.4 2 x 330 88 75 P40A48T0515 36-75 967 5.0 6.0 6800 ±15.0 ±0.3 2 x 110 88 75 Derating Page 1 of 2 Deutschland: Schweiz: Inselkammerstraße 10 Gründenstraße 82 D-82008 Unterhaching CH-8247 Flurlingen Tel.: 089 614 503-10 Tel.: 052 647 42 00 E-Mail: power@hy-line.de E-Mail: power@hy-line.ch
40W DC-DC Converter P40A-Series Specifications Input Voltage range 18-36, 36-75VDC Filter (see note 1) L-C type Under voltage lockout 24V Input model 48V Input model DC-DC On max. 17.8 VDC DC-DC Off min. 16 VDC DC-DC On max. 36 VDC DC-DC Off min. 34 VDC Output Output Power 40 W max. Voltage accuracy full load and nominal Vin Single / Dual: ±1% Triple main: ±1% Auxiliary ±3% Voltage adjustability (see note 2) Single output only ±10% Ripple and noise (at 20 MHz BW) See table measured with C L 104pF Short circuit protection Hiccup, automatics recovery Line voltage regulation LL to HL at Full Load Single/Dual: ±0.5% Triple main: ±1% Triple auxiliary: ±5% Load voltage regulation single: ± 0.5% dual: ±1% Triple Main: ±2% Triple Auxiliary: ±5% Temperature coefficient ± 0.02% / °C, max Minimum load Single: and Dual: 0% Triple: 10% of full load Note1: An external filter capacitor is required for normal operation. The capacitor should be capable of handing 1A ripple current for 24V and 48V models. Example: 220µF/ 100V, ESR <90mΩ. Note2: Maximum output deviation is 10% inclusive of remote sense and trim. If remote sense is not being used, the +SENSE should be connected to its corresponding +OUTPUT and likewise the sense should be connected to its corresponding -OUTPUT. Pin connections Dimensions Pin Standard Single Dual Triple 1 + Input + Input + Input 2 - Input - Input - Input
3 CTRL CTRL CTRL
4 NC 3.3 V + AUX 5 - Sense (note 2) 3.3V RTN (COM) Common 6 +Sense (note 2) NC - AUX 7 + Output NC + Output 8 - Output 5V - Output (COM)
9 TRIM 5V RTN (COM) NC
Switching frequency 300 kHz, typ. Environmental Operating temperature -40°C to +85°C (with derating) Storage temperature range -55 °C to +105 °C Maximum case temp. +100 °C Relative humidity 5% to 95% Cooling Free-air convection Physical Dimensions 2 x 2 inches 50.8 x 50.8 x 10.2 mm Weight 60 g Case material Nickel-coated copper Isolation Rated voltage 1600 VDC, min Resistance 10 Ω, min. Capacitance 1000pF, max Remote control Remote control on Remote control off Pin: CTRL Open 3.5V < Vr < 12V Short or 0V < Vr < 1.2V (referenced to Input) Life Support Policy: HY-LINE does not authorize the use of any of its products for use in life support devices or systems without the express written approval of an officer of the Company. Life su pport systems are devices which support or sustain life, and whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonabl y expected to result in significant injury to the user. Rev: 11 / 2004 f 2.00 (50.8) 0.40 (10.2) 0.20 (5.1) 1.80 (45.7) 2.00 (50.8) 0.80 (20.3) 0.60 (15.2) 0.30 (7.6) 0.10 (2.5) 0.50 (12.7) 0.20 (5.1) 87 659 0.40 (10.2) 0.22 (5.6) 1. All dimensions in Inches (mm) 2. Pin pitch tolerance ±0.014(0.35) DIA. 0.04 1.15 (29.2) BOTTOM VIEW Deutschland: Schweiz: Inselkammerstraße 10 Gründenstraße 82 D-82008 Unterhaching CH-8247 Flurlingen Tel.: 089 614 503-10 Tel.: 052 647 42 00 E-Mail: power@hy-line.de E-Mail: power@hy-line.ch Output can be externally trimmed by using the method shown below. TRIM UP TRIM DOWN