DATASHEET SEARCH SITE | WWW.ALLDATASHEET.COM

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 4

Technical content

20 W DC-DC Converter P20E-Series

Deutschland: Schweiz: Inselkammerstraße 10 Hochstrasse 355 D-82008 Unterhaching CH-8200 Schaffhausen Tel.: 089 614 503-10 Tel.: 052 647 42 00 E-Mail: power@hy-line.de E-Mail: power@hy-line.ch

  • Wide input range
  • 3000 VDC isolation
  • Aluminium heat sink case
  • Continuous short circuit protection
  • Over current protection
  • Over continuous short circuit protection
  • Output over voltage protection
  • Over temperature protection
  • Wide operation temperature range -40...100 °C
  • Adjustable output voltage
  • On / Off remote control input
  • EN 50155 standard Model guide Type Input voltage Input current Output voltage [VDC] Output current Efficiency [%] typ. Capacitor load (note2) [µF] max. Nominal [VDC] Range [VDC] no load [mA] typ. full load [mA] typ. [mA] min. [mA] max. Single P20E243R3SK 24 13...70 10 710 3.3 0 4500 87 7000 P20E2405SK 24 13...70 10 950 5.0 0 4000 88 5000 P20E2412SK 24 13...70 10 940 12.0 0 1670 89 850 P20E2415SK 24 13...70 10 930 15.0 0 1330 90 700 P20E1103R3SK 110 42...176 10 160 3.3 0 4500 86 7000 P20E11005SK 110 42...176 10 205 5.0 0 4000 89 5000 P20E11012SK 110 42...176 10 210 12.0 0 1670 86 850 P20E11015SK 110 42...176 10 210 15.0 0 1330 86 700 Dual P20E243R3DK 24 13...70 10 970 ±3.3 0 ±2000 86 2 x 1000 P20E2405DK 24 13...70 10 925 ±5.0 0 ±833 90 2 x 680 P20E2415DK 24 13...70 10 925 ±15.0 0 ±666 90 2 x 470 P20E1103R3DK 110 42...176 10 220 ±3.3 0 ±2000 84 2 x 1000 P20E11005DK 110 42...176 10 210 ±5.0 0 ±833 87 2 x 680 P20E11015DK 110 42...176 10 210 ±15.0 0 ±666 87 2 x 470 Specifications Page 1 of 4 EMC Characteristics Radiated Emissions, EN50121-3-2 40 dBµV at 20…230 MHz 47 dBµV at 230 MHz…1 GHz Conducted Emissions EN 50121-3-2 (see figure 3) 99 dBµV at 150…500 kHz 93 dBµV at 500 kHz…30 MHz ESD, EN 50121-3-2, perf. crit. A Air ± 8 kV Contact ± 6 kV RS, EN 50121-3-2 perf. crit. A

20 V/m

EFT, EN 50121-3-2, perf. crit. A (see figure 3) 2 kV Surge, EN 50121-3-2, perf. crit. A (see figure 3) 2 kV CS, EN 50121-3-2 perf. crit. A 10 V PFMF, EN 61000-4-8 perf. crit. A

100 A/m

Operating ambient temperature (see derating diagram) -40… 61 °C, without derating -40… 100 °C, with derating Storage temperature -55…125 °C Case temperature 105 °C, max. Over temperature protection 115 °C surface, typ. Thermal impedance 11.5 K/W, typ. Humidity 95 %, max. non condensing Thermal shock IEC 60068 Mechnical shock and vibration EN 61373 Free air convection cooling 30…65 LFM (15...35 cm/s) Physical Dimensions 27.6 x 27.6 x 16.9 mm Weight 22.7 g Case material Copper Potting material Epoxy (UL94V-0 rated) Absolute maximum ratings Input voltage ≤100 ms P20E24xxSK 100 VDC, max. P20E110xxSK 185 VDC, max. Pin soldering temperature ≤ 260 °C, ≤ 10 s, ≥ 1.5 mm distance from body Input Start up voltage P20E24xxSK: 12.3 VDC P110E24xxSK: 40.5 VDC Under voltage lockout P20E24xxSK: 11.6 VDC P110E24xxSK: 38.4 VDC Filter Pi Network Start up time with R-load 30 ms, typ. Reflected ripple current 20 mAp-p, (see figure 1) ON / OFF Control threshold (see figures 6) On: 3...12 VDC or open input Off: 0...1.2 VDC Standby idle current 3 mA, typ. Isolation: Input / output voltage for 60 s Input or output to case for 60 s

3000 VDC

1600 VDC

Resistance 109 Ω Capacitance 2000 pF, typ. Output Voltage accuracy ± 1 %, max. Line voltage regulation ± 0.5 %, max. P20ExxxxDK ±1%,max. @ balanced load Voltage trim range (see fig. 5) ± 10 %, only single output type Over voltage protection 140 % of nominal Vout, typ. Over load protection 170 % of full load, typ. Short circuit protection, hiccup Indefinite, automatic restart Transient recovery time @ 25 % load change steps 250 µs, typ. Transient response deviation @ 25 % load change steps P20Exx3R3SK ± 5 %, max. All other: ± 3 %, max. Temperature coefficient ± 0.02 % / °C Ripple and noise (at 20 MHz BW) ≤ 75 mVp-p, (see figure 2) Cross deviation 5 %, typ. at 75 % load difference General Switching frequency P20E24xxx: 330 kHz, typ. P20E110xxx: 245 kHz, typ. Safety Standard EN 50155, EN-, IEC 60950-1 Reliability calculated MTBF MIL-HDBK-217F at 25 °C 190.000 h

Deutschland: Schweiz: Inselkammerstraße 10 Hochstrasse 355 D-82008 Unterhaching CH-8200 Schaffhausen Tel.: 089 614 503-10 Tel.: 052 647 42 00 E-Mail: power@hy-line.de E-Mail: power@hy-line.ch Notes: 1. All parameter are typical at 25 °C, nominal input voltage and full load specified, unless otherwise noted. 2. Capacitive load tested by minimal input voltage and constant resistive load. Figure 1 Measure circuit for reflected input ripple current Figure 2 Measure circuit for output ripple & noise voltage, measure band wide 20 MHz Figure 3 Application circuit for ripple & noise reduction to meet conducted emission EN 50121- 3-2 class A Table component for Figure 3 Type Cin C1…C6 L1 P20E24xxx 330 µF, 100 V, Nippon Chemicon, EKY-101ELL331ML25S None None P20E110xxx 100 µF, 250 V, Rubycon, 250BXF100M16x20-ND 1 µF, Ceramic, 250 V 12 µH Page 2 of 4 To meet the specified ripple and noise level are for the output filter circuit multilayer ceramic capacitors necessary. 33 µF + ESR <1 Ω @ 100 kHz +Vin Load -Vout -Vin/GND +Vout 26 µH Measure point DC DC RL +Vin -Vout +Vout DC DC 10 µF MLCC GND CH1 -Vin/GND +Vin - Vin -Vout +Vout Load DC DC + Cin EFT & Surge- Filter EMI-Filter C1………C6

Deutschland: Schweiz: Inselkammerstraße 10 Hochstrasse 355 D-82008 Unterhaching CH-8200 Schaffhausen Tel.: 089 614 503-10 Tel.: 052 647 42 00 E-Mail: power@hy-line.de E-Mail: power@hy-line.ch Figure 4 Output voltage trimming application (only single output converter) Figures 5 ON/OFF remote control application circuit ON/OFF remote control application circuit for inverse logic and higher input level possibility Page 3 of 4 +Vin -Vin/GND Ctrl 3 Load -Vout +Vout DC DC Remote control input on: 3 V…≤12 V or open off: 0…1.2 V +Vin -Vin/GND Ctrl.3 Load -Vout +Vout DC DC Remote control input off on on off -Vin/GND Load 6 -Vout 4 +Vout DC DC

5 Trim

-Vin +Vin

Deutschland: Schweiz: Inselkammerstraße 10 Hochstrasse 355 D-82008 Unterhaching CH-8200 Schaffhausen Tel.: 089 614 503-10 Tel.: 052 647 42 00 E-Mail: power@hy-line.de E-Mail: power@hy-line.ch Mechanical dimensions Page 4 of 4 Pin assignment Pin Single out Dual out 1 +Vin +Vin 2 -Vin -Vin 3 Rem. Ctrl. Rem. Ctrl. 4 +Vout +Vout

5 Trim Com

PHI-CON is a trademark of HY-LINE Holding GmbH. Only for professional use by professionals! Not for resale or distribution to the general public in any way! Read the instruc tions carefully before using! Life Support Policy: HY-LINE does not authorize the use of any of its products for use in life support devices or systems without the express written approval of an officer of the Company. Life support systems are devices which support or sustain life, and whose failure to p erform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in significa nt injury to the user. Rev: 20180910 f Note: All dimensions in mm 1. Pin diameter tolerance ±0.05 mm 2. Pin pitch and lengh tolerance ±0.35 mm 3. Pin to case tolerance ±0.5 mm 4. Case tolerance ±0.5 mm 5. Stand off tolerance ±0.1 mm 6. Recommented Pin hole diameter 1.5 mm