20W DC-DC Converter P20D-Series
- High efficiency up to 93%
- 2:1 wide input voltage range
- Over current protection
- Over voltage protection
- Continuous short circuit protection
- Adjustable output voltage
- On/Off - remote control input
- Soft start
- Standard 2" x 1" x 0.4" package Model selection guide Input current Typ Input voltage range [VDC] no-load [mA] full-load [mA] Output voltage [VDC] Output current range [mA] Efficiency typ. [%] Capacitor load max. (3) [µF] Single output P20D123R3S 9...18 60 1740 3.3 0…5500 90 10000 P20D1205S 9...18 60 1870 5 0…4000 92 6800 P20D1212S 9...18 30 1920 12 0…1670 90 1000 P20D1215S 9...18 30 1920 15 0…1330 90 680 P20D243R3S 18...36 35 860 3.3 0…5500 91 10000 P20D2405S 18...36 35 925 5 0…4000 93 6800 P20D2412S 18...36 25 945 12 0…1670 91 1000 P20D2415S 18...36 25 947 15 0…1330 91 680 P20D483R3S 36...75 25 425 3.3 0…5500 91 10000 P20D4805S 36...75 25 465 5 0…4000 93 6800 P20D4812S 36...75 15 475 12 0…1670 91 1000 P20D4815S 36...75 15 475 15 0…1330 91 680 Dual output P20D1212D 9...18 30 1940 ±12 0…±835 89 2 x 470 P20D1215D 9...18 30 1940 ±15 0…±665 89 2 x 330 P20D2412D 18...36 30 960 ±12 0…±835 90 2 x 470 P20D2415D 18...36 30 960 ±15 0…±665 90 2 x 330 P20D4812D 36...75 20 480 ±12 0…±835 90 2 x 470 P20D4815D 36...75 20 485 ±15 0…±665 89 2 x 330 Page 1 of 3 Deutschland: Schweiz: Inselkammerstrasse 10 Gründenstrasse 82 D-82008 Unterhaching CH-8247 Flurlingen Tel.: 089 614 503-10 Tel.: 052 647 42 00 E-Mail: power@hy-line.de E-Mail: power@hy-line.ch
20W DC-DC Converter P20D-Series Specifications Input Input Filter: Pi- type Under voltage lockout 12V type: on @ 8.6V, off @ 7.9V 24V type: on @ 17.8V, off @ 16V 48V type: on @ 33.5V, off @ 30.5V Input surge voltage 100 ms max. 24 V input : -0.7…50 V DC 48 V input : -0.7…100 V DC Start up time 20ms typ. Remote "off" input current 5mA @ nominal Vin Reflected ripple Input current 20mAp-p, typ (5) Isolation Isolation voltage Input to output 1600 V DC, 3sec. Resistance 10 Ω, min Capacitance 1200 pF, max Output over voltage protection with Z-diode clamp 3.3V-output-type 3.9V 5V-output-type 6.2V (± 6.2V) (±)12V-output-type 15V (±15V) (±)15V-output-type 18V (±18V) Voltage accuracy ±1% Voltage adjustability ±10% (only for single output) Cross regulation @ dual output ±5% (1) Ripple and noise (at 20 MHz BW) 75mVp-p (2) Short circuit protection Hicc up, automatics recovery Over load protection 140% typ. of full load Line regulation ± 0.5% Load regulation single: ±0.5% @ 0…100% load dual: ±1%, max. @ blanced load Temperature coefficient ± 0.02% / °C Transient recovery time 250µs (4) Transient response deviation ±3%...(4) Efficiency vs output current Page 2 of 3 General Switching frequency 330 kHz, typ. Standard in accordance with IEC 60950-1 EN60950-1 Conducted and radiated emissions EN55022 level A (7) ESD EN61000-4-2 pref. Criteria B Radiated immunity EN61000-4-3 pref. criteria A Fast transient EN61000-4-4 pref. criteria B Surge EN61000-4-5 pref. criteria B (8) Conducted immunity EN61000-4-6 pref. criteria A PFMF EN61000-4-8 pref. criteria A MTBF >680khrs Environmental Operating temperature -40°C to +85°C (with derating) Cooling Free-air convection Storage temperature -40 °C to +125 °C Maximum case temp. +100 °C Humidity 95% rel. Humidity Physical Dimensions 50.8 x 25.4 x 10.2 mm Weight 30 g Case material Nickel-coated copper Potting material Epoxy ( UL94-V0) Remote control input (6) Remote control on Remote control off Open input or 3.0V…12V Short to “–Vin” or 0V…1.2V Absolute specifications (9) Soldering temperature 260°C, 10s, 1.5mm from case 12 Vin types: 0.7…36Vdc 24 Vin types: 0.7…50Vdc Input voltage max. for 100ms 48 Vin types: 0.7…100Vdc Deutschland: Schweiz: Inselkammerstrasse 10 Gründenstrasse 82 D-82008 Unterhaching CH-8247 Flurlingen Tel.: 089 614 503-10 Tel.: 052 647 42 00 E-Mail: power@hy-line.de E-Mail: power@hy-line.ch
+ OUTPUT R - Trim down R - Trim up - OUTPUT DC/DC - Converter P20Dxxxxx + INPUT L 12µH - INPUT Remote ON Remote OFF + 220µF 2.2µF < 90 mΩ 100V The output voltage can be externally trimmed by using the method shown below. ( ) for dual output trim 20W DC-DC Converter P20D-Series Circuit diagram 1. One load is 25% to 100% load, the other load is 100% load, the output voltage variable rate is within ±5%. 2. Measured with 20 MHz bandwidth and 1.0 µF ceramic capacitor. 3. Tested by minimal Vin and constant resistive load. 4. Tested by normal Vin and 25% load step change ( 75%-50%-25% of Io ). 5. Measured Input reflected ripple current wi th a simulated source inductance of 12µH. 6. The remote on/off control pin is referenced to -Vin(pin2). 7. Input filter components (C1, L) are used to help meet conducted emissions requirement for the module. 8. An external filter capacitor is required if the module has to meet EN61000-4-4 and EN61000-4-5. Suggested filter capacitor, Nippon Chemi-Con KY series, 220µF/100V for 24V and 48V Vin-types or 330µF/50V for 12V Vin-types. 9. Exceeding the absolute ratings of the unit could cause damage. Dimensions Pin connections Page 3 of 3 Pin Single Dual 1 + Input + Input 2 - Input - Input 3 + Output + Output
4 Trim Common
6 CTRL CTRL
Deutschland: Schweiz: Inselkammerstrasse 10 Gründenstrasse 82 D-82008 Unterhaching CH-8247 Flurlingen Tel.: 089 614 503-10 Tel.: 052 647 42 00 E-Mail: power@hy-line.de E-Mail: power@hy-line.ch Life Support Policy: HY-LINE does not authorize the use of any of its products for use in life support devices or systems without the express written approval of an officer of the Company. Life s upport systems are devices which support or sustain life, and whos e failure to perform, when properly used in accordance with inst ructions for use provided in t he labeling, can be reasonably expe cted to result in significant injury to the user. Rev: 03/10 f