OPTEK Technology Inc. — 1645 Wallace Drive, Carrollton, Texas 75006 Phone: (972) 323-2200 or (800) 341-4747 FAX: (972) 3 23-2396 sensors@optekinc.com www.optekinc.com Issue C 11/2010 Page 1 of 3 OPTEK reserves the right to make changes at any time in order to improve design and to supply the best product possible. Photologic® Optically Coupled Isolator OPI125, OPI126, OPI127, OPI127-032, OPI128 Applications:

  • High voltage isolation between input and output
  • Electrical isolation in dirty environments
  • Industrial equipment
  • Medical equipment
  • Office equipment Description: Each OPI125, OPI126, OPI127, OPI127-032 and OPI128 consists of an optically coupled isolator with a gallium arsenide infrared emitting diode coupled to a monolithic integrated circuit. This circuit incorporates a photodiode, a linear amplifier and a Schmitt trigger on a single silicon chip. For maximum long-term stability, both the diode and the Photologic® sensor are hermetically sealed in separate packages and then mounted in a high dielectric plastic housing. These devices feature TTL/LSTTL compatible logic level output that can drive up to 8 TTL loads directly without additional circuitry. Also featured are medium-speed data rates to 250 KBit/s, with typical rise and fall times of 70 nanoseconds. *UL recognition is for 15KVDC to 100° C. TX and TXV processing is available. For more information, contact your local representative or OPTEK. Features:
  • Four output options
  • 15 kV input-to-output isolation voltage
  • Direct TTL/STTL interface
  • High noise immunity Product Photo Here RoHS

Ordering Information

Photologic® Isolation Voltage (,000) tPLH / tPHL Typ (µs) IF (mA) Typ / Max VCE (Volts) Max Lead Length / Spacing *Length OPI125 890 nm or 935 nm Totem Pole 15 5 / 5 7.5 / 25 35.0 0.40" / 0.75" 0.75” [19mm] OPI126 Open Collector OPI127 Inverted Totem Pole OPI127- 032 Inverted Totem Pole 1.26” [32mm] OPI128 Inverted Open Collector 0.75” [19mm]

  • Data rates to 250 KBit/s
  • Hermetically sealed
  • TX-TXV process available
  • UL File No. E 58730* * See Table Pin # LED Pin # Photologic®

1 Anode 3 Output

2 Cathode 4 Vcc

5 Ground

[MILLIMETERS] DIMENSIONS ARE IN:

OPTEK Technology Inc. — 1645 Wallace Drive, Carrollton, Texas 75006 Phone: (972) 323-2200 or (800) 341-4747 FAX: (972) 3 23-2396 sensors@optekinc.com www.optekinc.com Issue C 11/2010 Page 2 of 3 OPTEK reserves the right to make changes at any time in order to improve design and to supply the best product possible. Photologic® Optically Coupled Isolator OPI125, OPI126, OPI127, OPI127-032, OPI128 Absolute Maximum Ratings (TA = 25o C unless otherwise noted) Storage Temperature -55° C to +100° C Operating Temperature -55° C to +100° C Input-to-Output Isolation Voltage(1)(2) ± 15 kVDC Lead Soldering Temperature (1/16” (1.6 mm) from case for 5 seconds with soldering iron)(3) 260° C Input Diode Forward DC Current 25 mA Reverse DC Voltage 2 V Power Dissipation(4) 200 mW Output Photosensor Output Photologic® Power Dissipation(5) 120 mW/° C Duration of Output Short to VCC or Ground (OPI125, OPI127) 1.00 second Duration of Output Short to VCC (OPI126, OPI128) 1.00 second Voltage at Output Lead (OPI126, OPI128) 35 V Supply Voltage, VCC (not to exceed 3 seconds) +10 V Notes: (1) Measured with input and output leads shorted. (2) UL recognition is for 3750 VAC to 100° C. (3) RMA flux is recommended. Duration can be exten ded to 10 seconds maximum when flow soldering. (4) Derate linearly 1.33 mW/° C above 25° C. (5) Derate linearly 3.40 mW/° C above 25° C. OPI125 - Totem Pole Output OPI126 - Open Collector Output OPI128 - Inverted Open Collector OutputOPI127 - Inverted Totem Pole Output

OPTEK Technology Inc. — 1645 Wallace Drive, Carrollton, Texas 75006 Phone: (972) 323-2200 or (800) 341-4747 FAX: (972) 3 23-2396 sensors@optekinc.com www.optekinc.com Issue C 11/2010 Page 3 of 3 OPTEK reserves the right to make changes at any time in order to improve design and to supply the best product possible. Photologic® Optically Coupled Isolator OPI125, OPI126, OPI127, OPI127-032, OPI128 Electrical Characteristics (TA = -40o C to +85° C unless otherwise noted) SYMBOL PARAMETER MIN TYP MAX UNITS TEST CONDITIONS Diode Input (See OP130 and OP230 for additional information - for reference only) VF Forward Voltage - - 1.5 V I F = 10 mA, TA = 25° C IR Reverse Current - - 100 µA V R = 2 V, TA = 25° C IF(+) LED Positive-Going threshold Current - - 7.5 mA V CC = 5 V, TA = 25° C IF(+)/IF(-) Hysteresis Ratio - 2.0 - - - Photologic® Output (See OP800 and OP801 for additional information - for reference only) VCC Operating Supply Voltage 45 - 5.5 V - ICC Supply Current - - 20 mA V CC = 5.5 V, IF = 0 or 7.5 mA VOL Low Level Output Voltage OPI125 OPI126 OPI127 OPI128 0.40 0.40 0.40 0.40 V VCC = 4.5 V, IOL = 13 mA, IF = 0 mA VCC = 4.5 V, IOL = 13 mA, IF = 0 mA VCC = 4.5 V, IOL = 13 mA, IF = 7.5 mA VCC = 4.5 V, IOL = 13 mA, IF = 7.5 mA VOH High Level Output Voltage OPI125 OPI127 2.4 2.4 - V VCC = 4.5 V, IOH = -800 µA, IF = 7.5 mA VCC = 4.5 V, IOH = -800 µA, IF = 0 mA IOS Short Circuit Output Current OPI125 OPI127 -20 -20 -120 -120 mA VCC = 5.5 V, IF = 7.5mA, Output = GND VCC = 5.5 V, IF = 0 mA, Output = GND IOH High Level Output Current OPI126 OPI128 100 100 µA VCC = 4.5 V, VOH = 30 V, IF = 7.5 mA VCC = 4.5 V, VOH = 30 V, IF = 0 mA tr, tf Output Rise Time, Output Fall Time OPI125, OPI127 - 100 - ns VCC = 5 V, TA = 25° C, IF = 0 or 10 mA, f = 10 kHz, D.C. = 50%, RL = 8 TTL loads Output Rise Time, Output Fall Time OPI126, OPI128 - 100 - VCC = 5 V, TA = 25° C, IF = 0 or 10 mA, f = 10 kHz, tPLH, tPHL Propagation Delay, Low-High, High-Low OPI125, OPI127 - 5 - µs VCC = 5 V, TA = 25° C, IF = 0 or 10 mA, f = 10 kHz, D.C. = 50%, RL = 8 TTL loads Propagation Delay, Low-High, High-Low OPI126, OPI128 - 5 - VCC = 5 V, TA = 25° C, IF = 0 or 10 mA, f = 10 kHz, Notes: (1) Measured with input and output leads shorted in air with a ma ximum relative humidity of 50%. If suitably encapsulated or oil- immersed, the isolation voltage is increased to 25 kV minimum.