International Safety Standard Approvals VDE0805/EN60950/IEC950/IEC1010 File No. 10401-3336-1076 Licence No. 70567, 1076 and 90354 UL1950 File No. E136005 CSA C22.2 No. 950 File No. LR41062C Certificate No. PS/605108 NAN40 SERIES Dual and triple output [ 2 YEAR WARRANTY ]
- 5.0 x 3.0 x 1.2 inch package (1U applications)
- Ideal for high volume designs
- Industry standard package
- Overvoltage and short circuit protection
- 40W with free air convection
- EN55022, EN55011 conducted emissions level B The NAN40 series are 40W universal input AC/DC power supplies on a 5 x 3 inch card with a maximum component height of 1.2 inch for use in 1U applications. These series are available with a wide range of models in the industry standard 5 x 3 inch footprint at low cost making the series ideal for new and existing high volume communication and industrial applications. The NAN40 series provide 40W of output power with free air convection cooling with a peak output of 50W for a maximum duration of 60 seconds. The NAN40 series are designed for use in high volume low power data networking, computer and telecom applications such as hubs, routers, POS terminals, cable modems and PABX's. This list is not exclusive as the generic feature set of both series with industry standard output configurations provide a solution for most high volume applications including many industrial applications. SPECIFICATION All specifications are typical at nominal input, full load at 25 ° C unless otherwise stated PAGE 1 EMC CHARACTERISTICS Conducted emissions EN55022, FCC part 15 level B Radiated emissions EN55022, FCC part 15 level A ESD air EN61000-4-2, level 3 Perf. criteria 2 ESD contact EN61000-4-2, level 4 Perf. criteria 2 Surge EN61000-4-5, level 3 Perf. criteria 2 Fast transients EN61000-4-4, level 3 Perf. criteria 2 Radiated immunity EN61000-4-3, level 3 Perf. criteria 2 Conducted immunity EN61000-4-6, level 3 Perf. criteria 2 GENERAL SPECIFICATIONS Hold-up time 110VAC 10ms @ 40W 230VAC 60ms @ 40W Efficiency 68% min. @ 40W Isolation voltage Input/output 3000VAC Input/chassis 1500VAC Switching frequency Variable Approvals and VDE0805, EN60950, IEC950 standards BABT, IEC1010, UL1950 (See Note 8) CSA C22.2 No. 950 Weight 200g (7.06oz) MTBF MIL-HDBK-217F 150,000 Hours ENVIRONMENTAL SPECIFICATIONS Thermal performance Operating 0°C to +70°C Non-operating -40°C to +85°C 0°C to 50°C ambient, 40W convection cooled 50°C to 70°C, Derate linearly ambient conv. cooled to half load Peak (0°C to 50°C) max. 60s 50W Relative humidity Non-condensing 5% to 95% RH Altitude Operating 10,000 feet max. Non operating 30,000 feet max. Vibration Three orthogonal axes, 2.4G rms random vibration, 10 5Hz to 500Hz minute test for each axis OUTPUT SPECIFICATIONS Line regulation Main output ±0.5% Auxiliary outputs ±1.0% Total regulation Main output ±3.0% Auxiliary outputs ±5.0% Overshoot/undershoot At turn-on < 10% Transient response +5.1V ±150mV max. dev., (1.5A to 3A step) 500µs recovery Temperature coefficient ±0.02%/°C Overvoltage protection +5.1V output 6.25V ±0.75Vout Output power limit Primary power 50W Pout, min. limited 110W Pin, max. Short circuit protection Multiple output 30 seconds INPUT SPECIFICATIONS Input voltage range Universal input 90 to 264VAC 120 to 370VDC Input frequency range 47Hz to 440Hz Input surge current 110VAC, cold start 15A 230VAC, cold start 32A Safety ground 110VAC, 60Hz 0.2mA leakage current 230VAC, 50Hz 0.4mA
P1 +12V V (B) P2 +5.1V V (A) P3 +5.1V V (A) P4 Return Return P5 Return Return P6 N/C V (C) Notes 1 Natural convection cooling (40W maximum).
2 Peak output current lasting less than 60 seconds with duty cycle less than
5%. During peak loading, output voltage may exceed total regulation limits. 3 Forced air, 20CFM at 1 atmosphere, 50W maximum. 4 Figure is peak-to-peak. Output noise measurements are made across a 50MHz bandwidth using a 12 inch twisted pair, terminated with a 47µF capacitor.
5 Total regulation is defined as the static output regulation at 25°C, including
initial tolerance, line voltage within stated limits, load currents within stated limits and output voltages adjusted to their factory settings. For multiple output units to maintain stated regulation then: 0.25 ≤ I A / IB ≤ 5, for IB > 0.3A 0.50 ≤ IA / IB ≤ 5, for IB < 0.3A Minimum load must also be 4W to achieve design MTBF . For maximum output current I C on triple-output models, i.e. for: IC = IMax., then IA min. ≥ 0.5A and IB ≥ IC.
6 Derating curve is application specific for ambient temperatures >50°C, for
optimum reliability, no part of the heatsink should exceed 120°C, and no semiconductor case temperature should exceed 130°C.
7 Caution: allow a minimum of 1 second after disconnecting line power
when making thermal measurements.
8 This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product. 20W 40W 50W 25W 0°C 10°C 20°C 30°C 40°C 50°C 60°C 70°C Available Output Power V's Ambient Temperature DERATING CURVE (See Notes 6, 7) Output Power (Watts) NATURAL CONVECTION COOLING 4W MIN. LOAD TO ACHIEVE DESIGN MTBF
20 CFM FORCED AIR COOLING
A Ground pad encircling mounting hole near P1 allows system grounding through a metal stand-off of up to 8mm max. diameter to metal chassis. B A standard L-bracket and cover is available for mounting, which contains all screws, connectors and necessary mounting hardware. Order part number ‘NAL40 COVER KIT’. 0.156 (3.96) Dia. (4 Places) 5.00 (127.00) MAXIMUM COMPONENT HEIGHT 1.2 inches F3.15A, 250VAC 2.55 (64.80) 0.22 (5.59) 3.00 (76.20) 4.55 (115.80) 0.22 (5.59) ALL DIMENSIONS IN INCHES (mm) AC (J1) mating connector Molex 09-50-3031 or equiv. with Molex 08-50-0105 or equiv. crimp terminals. DC (J2) mating connector Molex 09-50-3061 or equiv. with Molex 08-50-0164 or equiv. crimp terminals.
40 Watt
AC/DC universal input switch mode power supplies LOW TO MEDIUM POWER AC/DC POWER SUPPLIES | 40W AC/DC PAGE 2http://www.artesyn.com INPUT PIN CONNECTIONS Pin 1 AC Neutral Pin 2 No Pin Pin 3 AC Line Pin 1 Safety Ground OUTPUT OUTPUT CURRENT RIPPLE (4) TOTAL MODEL NUMBER (B) VOLTAGE MAX (1) PEAK (2) FAN (3) REG. (5) + 5.1V (IA) 3A 7A 4A 50mV ±3.0% NAN40-7608 (5) +12V (IB) 2A 3A 2A 120mV ±5.0% –12V (IC) 0.35A 1A 0.5A 120mV ±5.0% +5.1V (IA) 3A 7A 4A 50mV ±3.0% NAN40-7607 (5) +12V (IB) 2A 3A 2A 120mV ±5.0% +5.1V (IA) 3A 7A 4A 50mV ±3.0% NAN40-7629 (5) +12V (IB) 2A 3A 2A 120mV ±5.0% BTO_DS_NAN40_20011119.PDF Data Sheet © Artesyn Technologies® 2001 The information and specifications contained in this data sheet are believed to be correct at time of publication. However, Ar tesyn Technologies accepts no responsibility for consequences arising from printing errors or inaccuracies. Specifications are subject to change without notice. No rights under any patent accompa ny the sale of any such product(s) or information contained herein.