MTC600-ACNR16S1J ARTESYN | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 19
Technical content
Business-Critical Continuity MicroTCA MTC600 Series
600 Watts
- 600 W output power
- 16 Channels of
- 12 V @ 7.6 A max
- 3.3 V @ 150 mA max
- Supports:
- 12x AMC's
- 2x MCH's
- 2x CU's
- Supports N+1 output redundancy, N ≤3
- Supports 1+1 input redundancy Compliance
- PICMG MicroTCA.0 (Revision 1.0)
- PICMG HPM.1 Firmware Upgrade (Revision 1.0) Total Power: 600 Watts # of Channels: 16 General SXX06E Rev. 08.01.06 Page 1 of 2 Product Description The MTC600 series of Power Modules are designed for use in MicroTCA systems and can support shelves, cube and other implementations and is compliant to PICMG MicroTCA .0 Revision 1.0 specification. The MTC600 Power Modules implement the functionality necessary to power, manage and protect a MicroTCA system comprising up to: 12x AdvancedMCs 2x MicroTCA Carrier Hubs 2x Cooling Units The MTC600 Power Modules will: On system bring-up, provide the power necessary for MCH and CU system elements. Support redundant IPMI (IPMB-0) communication with the MCH/ Carrier-Manager Under the command of the carrier manager, enable and provide power to AMCs, CUs and additional MCHs Monitor and Report power system status and conditions of operation Manage and isolate faults affecting the power system Rev. 05.26.08 MTC600 Series 1 of 19 Safety UL, cUL 60950-1 CSA 60950-1 VDE 60950-1
Rev. 05.26.08 MTC600 Series 2 of 19 Embedded Power for Business-Critical Continuity Product Description (continued) Input EMI Filtering Transient Suppression Inrush Limiting Holdup Power Module Input Connector Monitoring Control Fusing ORing Power Conversion Power Module Output Connector 12V 3.3V - 48V_A - 48V_B Power Module Input Connector CU Power PWR MP EN# PS1# MCH Power PWR MP EN# PS1# PWRON AMC Power PWR MP EN# PS1# JTAG IPMB - 0 PM to Comm EMI Filtering Transient Suppression Inrush Limiting Holdup Power Module Input Connector Monitoring Control Fusing ORing Power Conversion Power Module Output Connector 12V 3.3V - 48V_A - 48V_B Power Module Input Connector CU Power PWR MP EN# PS1# MCH Power PWR MP EN# PS1# PWRON AMC Power PWR MP EN# PS1# JTAG IPMB - 0 PM to Comm CU (2x)Power Channel PWR MP EN# PS1# AMC (12x) Power Channel PWR MP EN# PS1# IPMB-0 JTAG MCH (2X) Power Channel PWR MP EN# PS1# PWRON PM to PM Comm EMI Filtering Transient Suppression Inrush Limiting Holdup
Rev. 05.26.08 MTC600 Series 3 of 19 Embedded Power for Business-Critical Continuity Electrical Specifications Input -48 Vdc Models Input Range (Operating) -39.5 to -72 Vdc Supports -48 V and -60 V battery plants Input Range (Non-operating) 0 to -39.5 Vdc -72 to -75 Vdc Power Module may or may not operate in part of this range, but will not be damaged Input Fusing Internal 24 A Fuses In both A & B feeds and A & B return lines Input ORing Internal In both A & B feeds and A & B return lines Inrush Current ≤80 A For t < 1 ms Input Current 12.8 A 18.2 A Typical with 600 W out, -54.0 Vin Maximum with 600 W out, -39.5 Vin Holdup Time 5 ms 7 ms 10 ms 10 ms Minimum at 600 W with one PM Typical at 600 W with one PM Typical at 400 W with one PM Minimum at 600 W with two PMs UnderVoltage Lockout 39.5 ±1.0 V 37.0 ±1.0 V Turn-On voltage Turn-Off voltage Reverse Polarity Protection Included Protected against reverse polarity over magnitude of specified input range AC Models Input Range (Operating) 90 to 264 Vac Supports typical worldwide single-phase inputs Input Range (Non-operating) 0 to 90 Vac 264 to 282 Vac Power Module may or may not be operating in part of this range, but will not be damaged Frequency 47 to 63 Hz Input Fusing Internal 15 A Fuses Inrush Current ≤45 A I 2t integral compatible with 15 A fast-blow fuse Power Factor 0.99 typical Meets EN61000-3-2 Harmonics <2.30 Arms (odd) <1.08 Arms (even) Input Current 2.95 A 6.6 A Typical with 600 W out, 230 Vac Maximum with 600 W out, 110 Vac Holdup Time 16.7 ms 20 ms At 110 Vac, 60 Hz At 230 Vac, 50 Hz UnderVoltage Lockout 87 ± 2.5 V 83 ± 2.5 V Turn-On voltage Turn-off voltage OverVoltage Lockout 282 Vac Power Module will turn-off if input voltage exceeds this voltage and not turn on until input voltage is reduced below this level
Output - All Models (continued)
12 V Outputs (Payload Power)1,2
Management Power Interdependence 12 V will not be applied without
3.3 V applied to a load
Removal of 3.3 V also removes 12 V and de-asserts ENABLE# Setpoint 12.6 Vdc typical
11.8 Vdc typical
Configured as Redundant PM Total Regulation Range 12.25 to 12.95 Vdc 11.60 to 12.00 Vdc Configured as Rrimary PM Configured as Redundant PM Rated Load 600 W maximum 80 W / 7.6 A maximum Per Power Module, input voltage ≥110 Vac Per load channel Minimum Load No load No loss of regulation ≥110 Vrms Output Rise TIme (per channel) 25 ms maximum With 1600 μF on output under test Output Noise (PARD)3 75 mV maximum 100 mV maximum 0 to 30 MHz 0 to 100 MHz Output Voltage Overshoot 2% maximum Referenced to setpoint Transient Response 3% maximum deviation 2 ms recovery time
2 A loadstep @ 1 A/μs
Referenced to load current and setpoint at onset of transient. Recovery time to within 1% of setpoint at onset of transient Voltage Sag 1.00 V maximum Primary PM to redundant PM transition with maximum of 80 W load per output or 600 W load per PM Short Circuit Protection 9.7 A maximum 10 ms maximum Output to return Channel Fault Operation (Output to Return) 12V Payload Power Output under fault is shutdown. 3V3 MP on the same channel is not affected. The other channels are not affected After removal of fault, the output channel is available again under control of the Carrier Manager. PM_OK# is not de-asserted and redundant failover is not initiated Channel Fault Operation (Output to Output) No damage to Power Module Either or both outputs may shut down until fault is removed PS1# Extraction Delay 100 μs maximum Time from de-assertion of PS1# to disabling of the channel outputs and de-assertion of the ENABLE# signal Reflected Ripple Tolerance on Cooling Unit Outputs4 100 mV pk-pk
0.8 A pk-pk
Tolerance of Power Module to ripple generated by fans or motors connected to Payload Power on Cooling Units Embedded Power for Business-Critical Continuity Rev. 05.26.08 MTC600 Series 4 of 19 Note 1: All channels and outputs must be con fi gued by the carrier manager with the exception of MCH and CU channels and outputs which are con fi gured during Startup and/or autonomous operation, Note 2: All measurements are made at the output connector of the Power Module. Unless otherwise speci fi ed,specs apply to all AMC, MCH, and CU outputs. Note 3: Measured with a 0.1 μF ceramic and 10 μF tantalum capacitor on any output and oscilloscope bandwidth set for 200 MHz. Note 4: Consult with the factory if other outputs are expected to product signi fi cant ripple current. Electrical Specifications (continued)
Rev. 05.26.08 MTC600 Series 5 of 19 Embedded Power for Business-Critical Continuity Output - All Models (continued)
3.3 V Outputs (Management Power) 5,6
Payload Power Interdependence 3.3 V must be applied before 12 V Removal of 3.3 V also removes 12 V and de-asserts ENABLE# Setpoint 3.3 Vdc typical Total Regulation Range 3.16 to 3.63 Vdc Rated Load 8 W maximum
0.5 W / 150 mA maximum
Minimum Load No load No loss of regulation Output Rise TIme (per channel) 25 ms maximum With 150 μF on output under test Output Noise (PARD)3 50 mV maximum 75 mV maximum 0 to 30 MHz 0 to 100 MHz Output Voltage Overshoot 2% maximum Referenced to setpoint Transient Response 3% maximum deviation 2 ms recovery time 37.5 mA loadstep @ 1 A/μs Referenced to load current and setpoint at onset of transient. Recovery time to within 1% of setpoint at onset of transient Voltage Sag 150 mV maximum Primary PM to redundant PM transition with max of 80 W load per output or 600 W load per PM Short Circuit Protection 225 mA maximum 12 ms maximum Output to return Channel Fault Operation (Output to Return) Output channel under fault is shutdown. Both 3.3V and 12V are removed and ENABLE# is de-asserted. The other channels are not affected After removal of fault, the output channel is available again under control of the Carrier Manager. PM_OK# is not de-asserted and redundant failover is not initiated Channel Fault Operation (Output to Output) No damage to Power Module Either or both channels may shut down until fault is removed PS1# Extraction Delay 100 μs maximum Time from de-assertion of PS1# to disabling of the channel outputs and de-assertion of the ENABLE# signal Note 5: All channels and outputs must be con fi gued by the carrier manager with the exception of MCH and CU channels and outputs which are con fi gured during Startup and/or autonomous operation. Note 6: All measurements are made at the output connector of the Power Module. Unless otherwise specifi ed,specs apply to all AMC, MCH, and CU outputs. Electrical Specifications (continued)
Rev. 05.26.08 MTC600 Series 6 of 19 Embedded Power for Business-Critical Continuity Output - All Models (continued) Electrical Specifications (continued) General Turn-on Time 4 seconds maximum After power-on of the PM, the time for autonomous outputs to reach regulation band Early Power Supported PM supports Early Power requirements refer- Normal Power Supported PM supports Normal Power requirements refer- Autonomous Operation Supported PM supports Autonomous Operation require- ments referenced in MicroTCA.0 Rev 1.0 Section 4.4.11.3 Diagnostic Mode Supported [GA2,GA1,GA0] = 101, or [GA2,GA1,GA0] = 110 LED1 displays yellow In Diagnostic Mode PM disables the IPMI con- trols and slots are powered up based only on PSI# signals Redundancy7 Hot-Swap Operation (controlled) Supported Removal or addition of a PM will not cause a fault or out-of-regulation condition Hot-Swap Operation (uncontrolled) Supported Removal or addition of a PM will not cause a fault or out-of-regulation condition Power Module Failover Supported When configured as a redundant PM, the PM is capable of accepting the load of a failed PM within specified voltage magnitude and timing parameters Fault Isolation Supported A fault in one PM will not cause the shutdown of another PM Note 7: All speci fi cations in the redundancy sub-section assume the system is populated with Power Modules with the same manufacturer's model numbers or otherwise compatible Power Modules. At the time of print, PICMG does not have a formal methodology for verifying compatibility.
Rev. 05.26.08 MTC600 Series 7 of 19 Embedded Power for Business-Critical Continuity Input Signals - All models Electrical Specifications (continued) Geographic Address: GA0, GA1, GA2 Internal pull ups to 3.3 V. Source current limited by 11 Kohm (300 μA with GAx at 0.0 V) MIN MAX Logic Level Low - VIL 0.5 V Logic Level High- VIH 1.63 V PS_PM#: PS_PM# Internal pull up to 3.3 V. Source current limited by 10 Kohm MIN MAX Logic Level Low Voltage - VIL 0.6 V Logic Level High Voltage - VIH 2.4 V PS1_[SLOT]#: PS1_M1, PS1_M2, PS1_CU1, PS1_CU2, PS1_1, ...PS_12 Internal pull ups to 3.3 V. Source current limited by 10 Kohm (330 uA with PS1_[SLOT]# at 0.0 V) MIN MAX Logic Level Low Voltage - VIL 1.1 V Logic Level High Voltage - VIH 2.6 V PWRON_[MCH]: PWRON_MI, PWRON_M2 MIN MAX Logic Level Low - VIL 0.5 V Logic Level High - VIH 1.63 V MIN MAX Logic Level Low - VIL 0.6 V Logic Level High - VIH 2.4 V Internal pull up to 3.3 V. Source current limited by 10 Kohm (330 uA with PMP_[x]# at 0.0 V) MIN MAX Logic Level Low Voltage - VIL 0.5 V Logic Level High Voltage - VIH 1.63 V
Rev. 05.26.08 MTC600 Series 8 of 19 Embedded Power for Business-Critical Continuity Output Signals - All Models Electrical Specifications (continued) EN1_[SLOT]#: EN1_M1, EN1_M2, EN1_CU1, EN1_CU2, EN1_1, EN1_2...EN1_12 Open collector output. Isink, max=10 mA. No internal current limit MIN MAX Logic Level Low Voltage - VOL 0.8 V Voltage Withstand - Vmax 5.5 V Open collector output, Isink, max = 10 mA. No current limit MIN MAX Logic Level Low Voltage, - VOL 0.8 V Voltage Withstand - Vmax 5.5 V PM_OK#: PM_OK# Open collector output, Isink max = 10 mA. No current limit MIN MAX Logic Level Low Voltage - VOL 0.8 V Voltage Withstand - Vmax 5.5 V SMP: SMP MIN MAX Voltage Range 4.5 V 6 V Isink 750 mA Isource 350 mA Shared Signals - All Models
Rev. 05.26.08 MTC600 Series 9 of 19 Embedded Power for Business-Critical Continuity Electrical Specifications (continued) SDA_[x]: SDA_A, SDA_B Internal pull ups to 3.3 V. Source current limited by 10 Kohm (330 μA with SDA_[x] at 0.0 V). Bufferede to support hot-swap MIN MAX Logic Level Low - VIL 0.7 V Logic Level High - VIH 2.70 V I2C Interface - All Models SCL_[x]: SCL_A, SCL_B MIN MAX Logic Level Low Voltage - VIL 0.7 V Logic Level High Voltage - VIH 2.70 V Operating Parameters I2C Operating Voltage 3.3 V Nominal I2C Operating Frequency 100 kHz
Rev. 05.26.08 MTC600 Series 10 of 19 Embedded Power for Business-Critical Continuity PM-EMMC IPMB-0 Interface Functionality A PM-EMMC is implemented per MicroTCA.0 R1.0 requirements 4.116 through 4.120 IPM Device IPMB Interface PM-EMMC aggregates IPMB-A and IPMB-B IPMI v1.5 protocol SDR Repository Sensors Implements mandatory 2 temp sensors; Implements voltage and current senors Watchdog Timer Implements a watchdog timer for resetting PM's own PM-EMMC FRU Inventory Initialization Agent PM-EMMC is responsible for initializing it's own event generation and sensors Internal Event Generation External Event Generation Events sent over IPMB-0 Power Channel Mapping Power Channel Management Power Payload Power PS1# ENABLE# Autonomous Power 1, 2 MP_M1, MP_M2 PP_M1, PP_M2 PS1_M1#, PS1_M2# EN_M1#, EN_M2# Depends on PWRON_ M1, PWRON_M2 3, 4 MP_CU1, MP_CU2 PP_CU1, PP_CU2 PS1_CU1#, PS1_CU2# EN_CU1#, EN_CU2# Yes 5-16 MP_1 - MP_12 PP_1 - PP_12 PS1_# - PS1-12# EN_1# - EN_12# No Global Commands NetFN App Request=06h; Response=07h Command CMD Note Get Device ID 01h As defined in IPMI v1.5; Broadcast Get Device ID not supported Cold Reset 02h As defined in IPMI v1.5 Event Commands NetFN S/E Request=04h; Response=05h Command CMD Note Set Event Receiver 00h As defined in IPMI v1.5 Get Event Receiver 01h As defined in IPMI v1.5 Platform Event 02h As defined in IPMI v1.5 Supported Commands
Rev. 05.26.08 MTC600 Series 11 of 19 Embedded Power for Business-Critical Continuity Supported Commands (Continued) IPMB-0 Interface (continued) Sensor Device Commands NetFN S/E Request=04h; Response=05h Command CMD Note Get Device SDR Info 20h As defined in IPMI v1.5 Get Device SDR 21h As defined in IPMI v1.5 Reserve Device SDR Repository 22h As defined in IPMI v1.5 Set Sensor Hysteresis 24h As defined in IPMI v1.5 Get Sensor Hysteresis 25h As defined in IPMI v1.5 Set Sensor Threshold 26h As defined in IPMI v1.5 Get Sensor Threshold 27h As defined in IPMI v1.5 Get Sensor Reading 2Dh As defined in IPMI v1.5 FRU Device Commands NetFN Storage Request=0Ah; Response=0Bh Command CMD Note Get FRU Inventory Area Info 10h As defined in IPMI v1.5 Read FRU Data 11h As defined in IPMI v1.5 Write FRU Data 12h As defined in IPMI v1.5 PICMG Commands NetFN Storage Request=2Ch; Response=2Dh Command CMD Note Get PICMG Properties 00h As defined in MicroTCA.0 R1.0 Get FRU LED Properties 05h As defined in PICMG3.0 R2.0 (ATCA) Get LED Color Capabilities 06h As defined in PICMG3.0 R2.0 (ATCA) Set FRU LED State 07h As defined in PICMG3.0 R2.0 (ATCA) Get FRU LED State 08h As defined in PICMG3.0 R2.0 (ATCA) Set IPMB State 09h As defined in PICMG3.0 R2.0 (ATCA) Get Device Locator Reader ID 0Dh As defined in PICMG3.0 R2.0 (ATCA) Get IPMB Link Info 18h As defined in PICMG3.0 R2.0 (ATCA) MicroTCA Commands NetFN PICGMG Request=2Ch; Reponse=2Dh Command CMD Note Power Channel Control 24h As defined in MicroTCA.0.0 R1.0 Get Power Channel Status 25h As defined in MicroTCA.0.0 R1.0 PM Reset 26h As defined in MicroTCA.0.0 R1.0 Get PM Status 27h As defined in MicroTCA.0.0 R1.0 PM Heartbeat 28h As defined in MicroTCA.0.0 R1.0
Rev. 05.26.08 MTC600 Series 12 of 19 Embedded Power for Business-Critical Continuity IPMB-0 Interface (continued) Sensors - Mandatory per PICMG and Related Standards Sensors - Non-Mandatory per PICMG and Related Standards Event and Status Sensors These sensors are implemented according to the requirements and specifications of the relevant standards. Sensor Name Sensor Number Management Controller Device Locator 00h Power Channel Notification 01h PM Status 02h IPMB Physical Link 03h Hot Swap 04h Temperature Sensors All temperature sensors have an accuracy of 5%. All temperature sensors have an offset of -40 °C. Sensor Name Sensor Number Resolution Applicable Models Hotspot Temperature 05h 1 °C / bit All Ambient Temperature 06h 1 °C / bit All Thresholds Assertion/Deassertion Co mparison Returned Settable/Readable Upper Non-Recoverable Yes Yes R Upper Critical Yes Yes S/R Upper Non-Critical Yes Yes S/R Lower Critical Yes Yes S/R Lower Non-Critical Yes Yes S/RThresholds Assertion/Deassertion Co mparison Returned Settable/Readable Upper Critical Yes Yes S/R Lower Critical Yes Yes S/R Internal Voltage Sensors All voltage sensors have an accuracy of 2%. Sensor Name Sensor Number Resolution Applicable Models
12 Volt 07h 100 mV / bit All
3V3 Volt 08h 50 mV / bit All
5 V Volt 09h 50 mV / bit All
Thresholds Assertion/Deassertion Co mparison Returned Settable/Readable Upper Critical Yes Yes S/R Internal Current Sensors All current sensors have an accuracy of 2%. Sensor Name Sensor Number Resolution Applicable Models 12 V Current 0Ah 0.5 A / bit All 3V3 Volt 0Bh 50 mA / bit All
Rev. 05.26.08 MTC600 Series 13 of 19 Embedded Power for Business-Critical Continuity IPMB-0 Interface (continued) Sensors - Non-Mandatory per PICMG and Related Standards (continued) Thresholds Assertion/Deassertion Co mparison Returned Settable/Readable Upper Critical Yes Yes S/R Lower Critical Yes Yes S/R Lower Non-Recoverable Yes Yes R Input Voltage Sensors All voltage sensors have an accuracy of 2%. Sensor Name Sensor Number Resolution Applicable Models AC Input Voltage 0Ch 2.0 V / bit MTC600-AC only DC Input Votlage A 0Ch 0.5 V / bit MTC600-48 only DC Input Voltage B 0Dh 0.5 V / bit MTC600-48 only DC Input Or-ed 0Eh 0.5 V / bit MTC600-48 only Thresholds Assertion/Deassertion Co mparison Returned Settable/Readable No thresholds implemented n/a n/a n/a Input Current Sensors All current sensors have an accuracy of 2%. Sensor Name Sensor Number Resolution Applicable Models AC Input Current 0Dh 100 mA / bit MTC600-AC only DC Input Current 0Fh 100 mA / bit MTC600-48 only
Rev. 05.26.08 MTC600 Series 14 of 19 Embedded Power for Business-Critical Continuity Temperature and Altitude Derating8 Other Environmental Criteria Specification Reference Relative Hunidity 5% - 95%, non-condensing GR-63-CORE, R4-7; IEC 60068-2-56, 2-30 Vibration 0.1 g @ 5-100 Hz and back to 5 Hz at a rate of 0.1 octave/min or 1.5 g @ 100-500 Hz with 0.25 octave/min; 1.5 mm @ 2-9 Hz, 0.5 g @ 9-200 Hz GR-63-CORE, R4-58, R4-59; IEC 60068-2-6, 2-36 Shock 4 g @ 22 ms IEC 60068-2-27, 2-29 Drop Packaged: 450 mm drop height; Unpackaged: 25 mm drop height; Transportation: 1.2 m free fall GR-63-CORE, R4-8, R4-9 IEC 60068-2-32 Fire Resistance All material UL 94V-1 or better The Power Module will not hinder system compliance to the following environmental specifications: Telcordia GR-63-CORE Telcordia GR-1089-CORE NEBS Level 3, per SR-3580 ETS300 019-1-1, Part 1-1 (Class 1.2E equipment) ETS300 019-1-2, Part 1-2 (Class 2.3 equipment) ETS300 019-1-3, Part 1-3 (Class 3.2 equipment) Standards Compliance for Telecommunications Applications Environmental Specifications 60 m below to 1800 m above sea level Condition Temperature Load Storage Non-Operating -45 ˚C to +70 ˚C- Cold Start -20 ˚C to -5 ˚C Any valid condition Normal Operation -5 ˚C to 45 ˚C 100% Short Term Operation9 45 ˚C to 55 ˚C Linear derating to 80% at 55 ˚C 1800 m to 4000 m above sea level Condition Temperature Load Storage Non-Operating -45 ˚C to +70 ˚C- Cold Start -20 ˚C to -5 ˚C Any valid condition Normal Operation -5 ˚C to 35 ˚C 35 ˚C to 45 ˚C 100% System dependent Short Term Operation9 45 ˚C to 55 ˚C System dependent Note 8: 12 CFM air fl ow for -48 V model; 15 CFM airfl ow for AC model. Note 9: Short Term Operation de fi ned as total period of not more than 96 consecutive hours and total of not more than 15 days in 1 year.
Rev. 05.26.08 MTC600 Series 15 of 19 Embedded Power for Business-Critical Continuity Electromagnetic Compatibility All Models Radiated Emissions Standard Limits & Test Parameters Frequency Range Criteria EN55022, Class A Per Section 6 3 MHz to 1 GHz N/A GR-1089-CORE Per Section 3.2 10 KHz to 10 GHz N/A Conducted Emissions EN55022, Class A Per Section 6 150 KHz to 30 MHz N/A GR-1089-CORE Per Section 3.2 10 KHz to 30 MHz N/A ElectroStatic Discharge EN61000-4-2 8 KV Contact, 15 KV Air discharge Impulsive B Radiated Immunity EN61000-4-3 10 V/m (level measure unmodu- lated) 80% AM, 1 KHZ
80 MHz to 1GHz A
EN61000-4-4 5/50 ns 5 KHz pulse
1 KV direct
EN61000-4-6 3 V (level measured unmodulated) 80% AM, 1HKz
150 KHz to 80 MHz A
Voltage Dips & Interruptions EN61000-4-11 -100% for 10 ms @ 0°; -100% for 10 ms @ 180°; -60% for 100 ms; -30% for 500 ms; -100% for 5 s Impulsive B,C Fast Transients EN61000-4-4 5/50 ns 5 KHz pulse
500 V direct
EN61000-4-5 1.2/50 μsec pulse
2 KV Line to Earth
1 KV Line to Line
EN61000-4-5 1.2/50 μsec pulse
500 V Line to Earth
500 V Line to Line
-48 Vdc Models
Rev. 05.26.08 MTC600 Series 16 of 19 Embedded Power for Business-Critical Continuity Mechanical Specifications (continued) Front Panel - MTC600-48 Front Panel - MTC600-AC Weight: 25 oz. (700 grams) typical General - MTC600-48 Input Connector: Positronics QB7W2MN7T2, FCI 10070158, or equivalent Mating Connector: Positronics QB7W2F00QH0/AA, FCI 10070165, or equivalent Pinout: P1: Return P2: -48 V 1: Not Used 2: Not Used Input Connector: IEC 320-C14, or equivalent Mating Connector: IEC 320-C13, or equivalent Pinout: L: Line N: Neutral G: Ground Weight: 30 oz. (850 grams) typical General - MTC600-AC Front Panel Drawing for AC-input unit Green/Red LED Blue LED Front Panel Drawing for DC-input unit Green/Red LED Blue LED -48_B -48_A
Rev. 05.26.08 MTC600 Series 17 of 19 Embedded Power for Business-Critical Continuity Mechanical Specifications (continued) Output Connector
1 PS_PM#
(Last Mate) PM_OK# (3rd Mate) PS1_M1# (3rd Mate) PS1_CU1# (3rd Mate) EN_M1# (3rd Mate) EN_CU1# (3rd Mate) MP_M1# (3rd Mate) MP_CU1# (3rd Mate)
2 N/C PMP_A#
(3rd Mate) PS1_2# (3rd Mate) PS1_1# (3rd Mate) EN_2# (3rd Mate) EN_1# (3rd Mate) MP_2# (3rd Mate) MP_1# (3rd Mate)
3 N/C PMP_B#
(3rd Mate) PS1_4# (3rd Mate) PS1_3# (3rd Mate) EN_4# (3rd Mate) EN_3# (3rd Mate) MP_4# (3rd Mate) MP_3# (3rd Mate)
4 N/C PMP_C#
(3rd Mate) PS1_6# (3rd Mate) PS1_5# (3rd Mate) EN_6# (3rd Mate) EN_5# (3rd Mate) MP_6# (3rd Mate) MP_5# (3rd Mate)
5 N/C RST_PM_IN#
(3rd Mate) PS1_8# (3rd Mate) PS1_7# (3rd Mate) EN_8# (3rd Mate) EN_7# (3rd Mate) MP_8# (3rd Mate) MP_7# (3rd Mate)
6 N/C RST_PM_A#
(3rd Mate) PS1_10# (3rd Mate) PS1_9# (3rd Mate) EN_10# (3rd Mate) EN_9# (3rd Mate) MP_10# (3rd Mate) MP_9# (3rd Mate)
7 GA0
(3rd Mate) RST_PM_B# (3rd Mate) PS1_12# (3rd Mate) PS1_11# (3rd Mate) EN_12# (3rd Mate) EN_11# (3rd Mate) MP_12# (3rd Mate) MP_11# (3rd Mate)
8 GA1
(3rd Mate) RST_PM_C# (3rd Mate) PS1_M2# (3rd Mate) PS1_CU2# (3rd Mate) EN_M2# (3rd Mate) EN_CU2# (3rd Mate) MP_M2# (3rd Mate) MP_CU2# (3rd Mate)
9 GA2
(3rd Mate) SMP (3rd Mate) SCL_B (3rd Mate) SDA_B (3rd Mate) SCL_A (3rd Mate) SDA_A (3rd Mate) PWR_ON_M2 (3rd Mate) PWR_ON_M2 (3rd Mate) AB C D E F G H P1 PP_M1(2nd Mate) PP_1(2nd Mate) P13 P2 PP_CU1(2nd Mate) PP_2(2nd Mate) P14 P3 PP_CU2(2nd Mate) PP_3(2nd Mate) P15 P4 GND(1st Mate) PP_4(2nd Mate) P16 P5 GND(1st Mate) PP_5(2nd Mate) P17 P6 GND(1st Mate) PP_6(2nd Mate) P18 P7 GND(1st Mate) PP_7(2nd Mate) P19 P8 GND(1st Mate) PP_8(2nd Mate) P20 P9 GND(1st Mate) PP_9(2nd Mate) P21 P10 GND(1st Mate) PP_10(2nd Mate) P22 P11 GND(1st Mate) PP_11(2nd Mate) P23 P12 PP_M2(2nd Mate) PP_12(2nd Mate) P24 Pinout Pin Description PP_x Payload Power (12V) for AMC/MCH/CU x MP_x Mgmt Power (3.3V) for AMC/MCH/CU x GND Output Return PS_PM# Last Mate Pin GAx Geographical address line x PM_OK# PM Present and OK [Output] PMP_x# PM x Present and OK [Input] RST_PM_IN# Resets PM EMMC [Input] RST_PM_x# Reset signal from PM x [Output] PWR_ON_Mx Power-On signal from MCH x PS1_x# Detects Presence of AMC/MCH/CU x EN_x# Enables (E)MMC of AMC/MCH/CU x SCL_x I2C Clock Line for Bus x SDA_x I2C Date Line for Bus x Output Connector: EPT P/N 501-50096-183, Tyco P/N 1469922-1, or equivalent Mating Connector: EPT P/N 502-50096-183, Tyco P/N 1469920-1, or equivalent
Rev. 05.26.08 MTC600 Series 18 of 19 Embedded Power for Business-Critical Continuity Mechanical Specifications MTC600-48 MTC600-AC 7.37 (187.25) 2.89 (73.50) 2.34 (59.40) 3.22 (81.4) 7.37 (187.25) 2.89 (73.5) 15.24 (0.6) 0.18 (4.55) 0.63 (16) 15.24 (0.6)
Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. ©2006 Emerson Electric Co. Emerson Network Power. The global leader in enabling business-critical continuity. EmersonNetworkPower. com AC Power Connectivity DC Power Embedded Power Inbound Power Integrated Cabinet Solutions Outside Plant Precision Cooling Site Monitoring and Services This is a Preliminary Datasheet. Emerson Network Power reserves the right to make changes to the information contained herein without notice and assumes no liability as a result of its use or application. Rev. 05.26.08 MTC600 Series 19 of 19 Embedded Power for Business-Critical Continuity SXX06E Rev. 08.01.06 Page 1 of 2
Ordering Information
600 = 600 W Input Voltage 48 = -48 Vdc AC = 90-264 Vac Redundant RR = Redundant Input and Redundant Output NR = Non- Redundant Input and Redundant Output Channel Count 16 = 16ch Reserved For modifi ed standards Width S = Single Width Height 9 = 9 HP 1 = 12 HP MTC ppp - vv rr nn w h xx J MTC600-48RR16S9J
600 W, -48 Vin, Redundant I/P , Redundant O/P , 16 channel, SW 9 HP
600 W, AC -in, Non-Redundant I/P , Redundant O/P , 16 channel, SW 12 HP
5810 Van Allen Way
Carlsbad, CA 92008 USA Telephone: +1 760 930 4600 Facsimile: +1 760 930 0698 Europe (UK) Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX United Kingdom Telephone: +44 (0) 1384 842 211 Facsimile: +44 (0) 1384 843 355 Asia (HK) 16th - 17th Floors, Lu Plaza
2 Wing Yip Street, Kwun Tong
Kowloon, Hong Kong Telephone: +852 2176 3333 Facsimile: +852 2176 3888 For global contact, visit: www.astecpower.com www.artesyn.com technicalsupport@astec.com technicalsupport@artesyn.com While every precaution has been taken to ensure accuracy and completeness in this literature, Emerson Network Power assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. Printed in U.S.A. Issue SF3