Page 1 of 4 Jan 31, 2024 | Rev g | Doc: DS_M8747 Series M8747 SERIES DC/DC POWER SUPPLY Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in M8747 SERIES DC/DC POWER SUPPLY PRODUCT HIGHLIGHTS

  • MINIATURE
  • HIGH DENSITY
  • QUAD OUTPUT
  • DC/DC CONVERTER
  • UP TO 100W

Page 2 of 4 Jan 31, 2024 | Rev g | Doc: DS_M8747 Series M8747 SERIES DC/DC POWER SUPPLY Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in

Applications

Military, Ruggedized, Telecom, Industrial Special Features

  • Miniature size
  • High efficiency
  • Wide input range
  • Up to 15 W/IN³
  • Input / Output isolation
  • Fixed switching frequency (250 kHz)
  • TTL logic enable
  • EMI filters included
  • Indefinite short circuit protection with auto-recovery
  • Input over-voltage shutdown with auto-recovery
  • Over temperature shutdown with auto- recovery Environmental Conditions Meets or exceeds MIL-STD-810D Temperature: Operating –55C to +85C (baseplate) Storage –55C to +125C Altitude Method 500.4 Procedures I – Storage/Air transport: Up to 70,000 ft. (non-operational) Procedures II – Operation/Air Carriage: Up to 70,000 ft. (operational) Reliability 150,000 hours, calculated per MIL-STD-217F at +85C baseplate, ground fixed. Electrical Specifications DC INPUT DC Input range: 18 to 48 VDC Input transient protection: All models meet or exceed (no damage) MIL-STD-1275A (100V for 50 mSec) and MIL-STD-704A/D (80V for 0.1 Sec) Over-voltage shutdown with auto-recovery Efficiency: Up to 82% EMC: Designed to meet* MIL-STD-461F CE101, CE102, CS101, CS114, CS115, CS116, RE101, RE102, RS101, RS103 Isolation: 200V between Input and Output 200V between Input and Case DC OUTPUT (floating) Line/Load regulation: Less than 1% (no load to full load, –55C to +85C) Ripple and Noise: 50mVp-p, typical (max. 1%) Current limiting (Foldback): Continuous protection for unlimited time Over voltage protection: Passive transorb on output. Over temperature protection: Shutdown at baseplate temperature of +100C (5C) Automatic recovery at baseplate temperature lower than +90C (5C) Isolation: 100V between Output and Case * EMC compliance achieved when tested with 5 μH LISNs, shielded harness and static resistive load.

Page 3 of 4 Jan 31, 2024 | Rev g | Doc: DS_M8747 Series M8747 SERIES DC/DC POWER SUPPLY Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in PIN ASSIGNMENT Pin No. Pin Function Pin No. Pin Function Pin No. Pin Function

1 INHIBIT 15 - OUT 4 29 + OUT 1

2 SYN IN. 16 + OUT 4 30 + OUT 1 3 - OUT 2 SENSE RTN 17 - OUT 2 31 - VIN 4 - OUT 1 18 - OUT 2 32 - VIN 5 - OUT 1 19 - OUT 2 33 - VIN 6 - OUT 1 SENSE RTN 20 - OUT 2 34 + VIN 7 + OUT 1 21 SIGNAL RTN 35 + VIN 8 + OUT 1 22 CHASSIS 36 + VIN 9 + OUT 1 SENSE 23 - OUT 1 37 + OUT 2 10 -OUT 3 24 - OUT 1 38 + OUT 2 11 + OUT 2 SENSE 25 - OUT 1 39 + OUT 2 12 + OUT 3 26 - OUT 1 40 + OUT 2 13 - VIN 27 + OUT 1 14 + VIN 28 + OUT 1 Functions and Signals INHIBIT signal The INHIBIT signal is used to turn the power supply ON and OFF. TTL “1”or OPEN – will turn on the power supply (For normal operation leave the signal not connected). TTL “0” or short– will turn off the power supply. SYNC signal The SYNC signal is used to allow the power supply frequency to sync with the system frequency. The system frequency should be 250 kHz ± 10 kHz. When not connected the power supply will work at 250 kHz ± 10 kHz. SIGNAL RTN The SIGNAL RTN is used as a return path for SYNC and INHIBIT signals. This pin is referenced to VIN RTN. OUT 1 SENSE The SENSE is used to achieve accurate load regulation at load terminals. This is done by connecting the pins directly to the load terminals. The remote sense correction function is limited to voltage drop between converter’s output and load terminals of 2% to 5%, or up to 0.5V, the least of the two. When not used, connect OUT 1 SENSE to OUT 1 and - OUT 1 SENSE RTN to - OUT 1. Do not leave SENSE and SENSE RTN pins unconnected. These pins can be tied internally to avoid external connection, if function is not required – consult factory OUT 2 SENSE The SENSE is used to achieve accurate load regulation at load terminals. This is done by connecting the pins directly to the load terminals. The remote sense correction function is limited to voltage drop between converter’s output and load terminals of 2% to 5%, or up to 0.5V, the least of the two. When not used, connect OUT 2 SENSE to OUT 2 and - OUT 2 SENSE RTN to - OUT 2 Do not leave SENSE and SENSE RTN pins unconnected. These pins can be tied internally to avoid external connection, if function is not required – consult factory.

Page 4 of 4 Jan 31, 2024 | Rev g | Doc: DS_M8747 Series M8747 SERIES DC/DC POWER SUPPLY Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in OUTLINE DRAWING * Specifications are subject to change without prior notice by the manufacturer. Notes 1. Dimensions are in Inches [mm] 2. Tolerance is: .XX  0.01 in .XXX  0.005 in 3. Weight: Approx. 6 oz (170 g)