Page 1 of 18 Oct 27, 2023 | Rev (g) | Doc: DS_M2192 Series M2192 Series– DC/DC Power Supply Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in M2192 SERIES DC/DC OWER SUPPLY HIGHLIGHTS PRODUCT
- 1 VITA 62 ” Pitch
- SOSATM ALIGNED
- FACTOR 3U FORM
- 600W Steady State
- NED (Optional)
- OPERATING TEMP: –55°C to +85°C
- EMI: Compliant to MIL-STD-461G (5µ LISN)
- 810-STD-MIL Environmental:
- Input Options : o 704-STD-MIL o 1275-STD-Mil
Page 2 of 18 Oct 27, 2023 | Rev (g) | Doc: DS_M2192 Series M2192 Series– DC/DC Power Supply Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in SPECIAL FEATURES
- Compliant VITA 62
- Aligned with the SOSATM Technical Standard
- range Wide input
- Up to 600W output Steady state power
- Supports Mil-STD-1275E
- NED¹
- sense Remote
- ²Current Sharing
- kHz) 02Fixed switching frequency (2
- Protection Indefinite short circuit
- protection Reverse battery
- Over temperature shutdown with auto-recovery
- included EMI filters
- System Management: protocol per VITA 46.11 o currents Output voltages and o temperature Card o status Card system ¹ Optional by PN. Please see NED section for full compliance ² Optional by PN
Page 3 of 18 Oct 27, 2023 | Rev (g) | Doc: DS_M2192 Series M2192 Series– DC/DC Power Supply Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in SpecificationsElectrical DC Output PO1 & PO3 (VS1): 12V up to 50A PO2 (3.3VAux): 3.3V up to 15A Isolation Over 20 MΩ at test voltage: 200V between Input and Output 200V between Input and Case 100V between Output and Case Current Sharing 12V A.C.S Efficiency Up to 87 % Normal Quiescent Current: Inhibited Output: 193mA (3.3VAux Only) Disabled Input: 112mA (All Outputs Off) Line/Load regulation Ripple and Noise Typically, less than 50mVp-p (max. 1%p). Measured across a 0.1μF capacitor and 10μF capacitor on load at Input Voltage of 18V-36V, all Temperature Range. Load Transient Overshoot and Undershoot Output dynamic response of less than 5% at load Step of 30%-60%. Output returns to regulation in less than 1mSec EMC Design to meet: MIL-STD-461G1 CE101, CE102, CS101, CS114, CS115, CS116 Notes: 1. Compliance achieved with 5µH LISN and static resistive load.
- Output voltages and currents
- Input voltage
- Card
- temperature Electrical Specifications DC Input 18 to 48VDC steady state 30Sec Turn-off timer when input voltage goes below 20V Works through MIL-STD-1275E (Surges: 12V Initial Engagement, 16V Cranking, 100V) DC Output PO1 & PO3 (VS1): 12V up to 50A PO2 (3.3VAux): 3.3V up to 15A Isolation Over 20 MΩ at test voltage: 200V between Input and Output 200V between Input and Case 100V between Output and Case Current Sharing 12V A.C.S Efficiency Up to 87 % Normal Quiescent Current: Inhibited Output: 193mA (3.3VAux Only) Disabled Input: 112mA (All Outputs Off) Line/Load regulation Ripple and Noise Typically, less than 50mVp-p (max. 1%p). Measured across a 0.1μF capacitor and 10μF capacitor on load at Input Voltage of 18V-36V, all Temperature Range. Load Transient Overshoot and Undershoot Output dynamic response of less than 5% at load Step of 30%-60%. Output returns to regulation in less than 1mSec System management options: 1. I2C 2. Custom IPMI 3. VITA 46.11 Tier II IPMC Data available:
Page 4 of 18 Oct 27, 2023 | Rev (g) | Doc: DS_M2192 Series M2192 Series– DC/DC Power Supply Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in Environmental ¹ Design to Meet MIL-STD-810G Temperature Operating: –55°C to +85°C at unit Edge Storage: –55°C to +125°C Designed Design to meet 600 cycles VITA47 Reliability: TBD Hours, calculated IAW MIL-HDBK-217F Notice 2 at +65 ℃, GF. Note 1: Environmental Stress Screening (ESS) Including random vibration and thermal cycles is also available. Please consult factory for details . Protections ¹ Input Output General • Inrush Current Limiter • Passive over voltage • Over Temperature Protection Peak value of 5 x IIN for initial protection on 3.3VAux Automatic shutdown inrush currents lasting more 3.9V Zener. at internal temperature of 95 ± 5°C. than 50µSec. • Active over voltage Automatic recovery when
- Under Voltage protection on 12V output temperature drops below 90 ± 5°C. Unit shuts down when input 20% ± 5% above nominal steady state voltage drops below voltage. 17± 0.5VDC. Automatic recovery when Automatic restart when input output voltage drops below voltage returns to nominal threshold. range. • Overload / Short-Circuit protection Continuous protection (10-30%
- Input Overvoltage Protection above maximum current) for Unit shuts down when input unlimited time (Hiccup). steady state voltage rise above Automatic recovery when 55/85 ± 2VDC. overload/short circuit removed. Automatic restart when input voltage returns to nominal range. Note 1: Thresholds and protections can be modified / removed (please consult factory) Altitude Method 500.5, Procedure I & II Storage/Air transport 40Kft Operation/Air carriage 70Kft Salt Fog Method 509.5 Fungus Does not support fungus growth, in accordance with the guidelines of Mil-STD-454, Requirement 4. Humidity Method 5007.5, Up to 95% RH Vibration & Shock Shock: Saw tooth- 40h, 11mSec Vibration: Vita47 ClassV3.
- Input Overvoltage Protection shuts down input steady state voltage rise above 55/85 ± 2VDC Automatic restart when input voltage returns to nominal range.
Page 5 of 18 Oct 27, 2023 | Rev (g) | Doc: DS_M2192 Series M2192 Series– DC/DC Power Supply Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in Functions and Signals - According to VITA 62 Signal Name Type
Description
FAIL* Output Indicates to other modules in the system that a failure has occurred in one of the outputs. Please refer to Figure 2 ¹ SYSRESET* Output Indicates to other modules in the system that all outputs are within their working level. Please refer to Figure 2 ¹ INHIBIT * Input Controls power supply outputs. This signal in conjunction with ENABLE controls the outputs. Please refer to Table 1 and Figure 1 ¹ ENABLE* Input Controls power supply outputs. This signal in conjunction with INHIBIT controls the outputs. Please refer to Table 1 and Figure 1 ¹ NED Output NED event detector output. Normally Low, goes high and Latch during Event. Internal 2K pullup to 3.3V NED RETURN Output NED Return¹ GA0*, GA1*, GA2* Input Used for geographical addressing. GA2 is the most significant bit and GA0 is the least significant bit. ¹ SCL_A, SDA_A Bidirectional I2C bus Clock and Data respectively. Through this bus the voltage and temperature readouts can be shared. ¹ SCL_B, SDA_B Bidirectional Redundant I2C bus Clock and Data respectively. Through this bus the voltage and temperature readouts can be shared. ¹ Sync_In Input TBD. VOUT SENSE Input The SENSE is used to achieve accurate load regulations at load terminals (this is done by connecting the pins directly to the load’s terminals). 3.3Vaux A.C.S Bidirectional Support 3.3Vaux Active current share between Outputs. See Current Share para. ¹ ² ³ (Optional, non-SOSA configuration) #_SHAREPO Bidirectional Support current share between Outputs¹ Notes: 1. Signal referenced to SIGNAL RTN. 2. open When not used leave 3. for 3.3Vaux In Passive or Non-Current Share configuration, this pin is Internally Disconnected.
Page 7 of 18 Oct 27, 2023 | Rev (g) | Doc: DS_M2192 Series M2192 Series– DC/DC Power Supply Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in Simplified Block Diagram
Page 8 of 18 Oct 27, 2023 | Rev (g) | Doc: DS_M2192 Series M2192 Series– DC/DC Power Supply Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in InformationDetailed 1. Operati M2192 Input Voltage n The M2192 steady state operation voltage is 18V to 48V and will continuously work through Mil -STD-1275E. 12V and 100V Surges
1.1 Steady state Low Line Turn-on and Turn-off Limits
To avoid Turn-on and Turn-off glitch the unit have about 2V Hysteresis. The Turn-on threshold is under 20V and turn- off under 18V. Those limits can be adjusted, contact Factory for more information. Unit will automatically shut down after about 30Sec if input voltage remains under 2 0V.
1.2 Mil-STD-1275E, 12V Input Transient
- Regulation Outputs Voltage The M2192 contains accurate internal sense lines to keep output voltage at less than 4% regulation for all Line/ Load and temperature range (see Table 2). Table 2: Outputs voltage regulation. VIN 18V to 48V, Temperature -55 to 85 C Output Voltage Range 12V/ 50A 3.3V/15A Active Current Share 12.15V -11.85V 3.42V -3.28V Passive Current Share N/A 3.45V -3.25V
Page 9 of 18 Oct 27, 2023 | Rev (g) | Doc: DS_M2192 Series M2192 Series– DC/DC Power Supply Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in
3.1 Lines Sense
Sense Lines are provided for 12V and 3.3V outputs to compensate line voltage drop. Sense Lines proper connection is shown in Figure 3. Each VSx output has its own Sense Lines, additional common Sense RTN Line is provided for all VSx Outputs (VITA 62 Standard). Contact Factory for Sense configuration different than the VITA 62 standard Figure 4: M2192 Sense line connection
Page 10 of 18 Oct 27, 2023 | Rev (g) | Doc: DS_M2192 Series M2192 Series– DC/DC Power Supply Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in 4. (C.S) Current Share Current Share of two or more units is optional (Contact Factory) 12V output and 3.3VAux will current share with about 2-4A load balance. 4.1 Active current sharing (A.C.S) Current sharing done in a closed loop. All paralleled outputs are compared and feedback is used to balance their load current. The result is a more stable, less sensitive output voltage without voltage drop. Typical Load Balance of about 2-4A for all Load range is expected. ACS is supported by the 12V output. ²Optional for 3.3Vaux¹ . Current sharing is done in open loop, output voltage drops as a function of output load. 10% is expected-Load Balance of about 5. 4.3 ² Vaux ACS is optional¹ 3.3 Current share connection between two Units. For a required output to current share please connect the following Pins between the two units
- PO#_Sense & PO#_Sense_RTN (for best performance, Pins from paralleled units should be connected to a single point and as close as possible to the load point)
- (A7) VS1_SHARE
- (C7) VS1_ ACS
- (B7) 3.3Vaux_SHARE
- ²Optional¹ 3.3Vaux_ACS (D1) Typical ACS Dynamic Load of Two 12V Paralleled Outputs (PO1 & PO2 refer to two different units) When ordering 3.3Vaux P.C.S or 3.3Vaux Non-Current Share unit, this pin is Internally disconnected 2. 3.3Vaux ACS (Pin D1) is not required by SOSA and is optional. (Pin was previously on Pin B4)
Page 11 of 18 Oct 27, 2023 | Rev (g) | Doc: DS_M2192 Series M2192 Series– DC/DC Power Supply Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in 5. NED
5.1 NED circuit operation
NED Output is Normally Low, goes High After NED detection NED circuit operation needs to be verified by User
5.2 Power Supply compliance
Power supply performance during and after NED event needs to be verified by User. For additional information, please contact factory. 6. Efficiency 7. Tests EMI CE102 Left Empty
Page 12 of 18 Oct 27, 2023 | Rev (g) | Doc: DS_M2192 Series M2192 Series– DC/DC Power Supply Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in 8. Protocol Communication Unit communication protocol can be configured as Vita 46.11 Tier 2 IPMC or Custom IPMI compatible protocol. For more details on protocols refer to para. 6.1 and 6.2
8.1 Protocol IPMICustom
Vcc: 3.3VDC Pull-up: 20kOhm Input capacitance: 100pf Slave Device Addressing - 256 spaces address - maximum Baud rate: 200kHz - 7 Protocol Bit - Support Slot Addressing per VITA 62 MSB LSB Slot Number A6 A5 A4 A3 A2/GA2* A1/GA1 * A0/GA0 * R/W Slot0 0 1 0 0 0 0 0 Slot1 0 1 0 0 0 0 1 Slot2 0 1 0 0 0 1 0 Slot3 0 1 0 0 0 1 1 * Slot location is determined by GAx per VITA 62. Communications Supported Read Command – 21Hex, deliver 64Bytes of Data. (More commands are available by request) The communication starts when the master sends a start followed by the unit slave address, command, checksum and a stop. A second start followed by the slave address and a read will be followed by a 64 Bites response. S AddressSlave R/W A Command A Check sum A P A6:A0 0 0 21 Hex 0 DF Hex 0 W S Slave Address R/ A DATA A DATA A DATA A
- •• DATA A Check sum N/A P A6:A0 1 0 D7:D0 0 D7:D0 0 D7:D0 0 D7:D0 0 D7:D0 1 Command – 21Hex read all 64 Bytes S -Start Stop -P Master Transmit Unit Transmit
Page 13 of 18 Oct 27, 2023 | Rev (g) | Doc: DS_M2192 Series M2192 Series– DC/DC Power Supply Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in Memory Space Response Byte # Data Type Meaning Interpretation Reading Range
0 U Integer, MSB First Echo of Command 21 Hex
1 N/A 00 Hex
3-2 S Integer, MSB First Temperature -55C to 120C 7bit Dec -T(Cᵒ)=+/ -55°C to 125°C 5-4 U Integer, MSB First 12V VS1 Voltage V(out) = Dataˑ m2 20.48V 7-6 FirstU Integer, MSB 3.3V VS2 Voltage V(out) = Dataˑ m2 20.48V 9-8 U Integer, MSB First N/A N/A N/A 11-10 U Integer, MSB First N/A N/A N/A 13-12 U Integer, MSB First N/A N/A N/A 15-14 U Integer, MSB First N/A N/A N/A 17-16 U Integer, MSB First 12V VS1 Current V(out) = Dataˑ m3 80A 19-18 U Integer, MSB First 3.3V VS2 Current V(out) = Dataˑ m3 20A 21-20 U Integer, MSB First N/A N/A N/A 23-22 U Integer, MSB First N/A N/A N/A 35-24 U Integer, MSB First N/A N/A N/A 27-26 U Integer, MSB First N/A N/A N/A 29-28 U Integer, MSB First Reserved 00Hex 31-30 U Integer, MSB First Reserved 00Hex 51-32 Character String (ASCII) Part Number xxx-2192M* )Note1 ( 20 Characters 53-52 Decimal, MSB First Serial Number, 2MSB Dig X,X Dec )Note2 ( Optional 55-54 Decimal, MSB First Serial Number, 2LSB Dig X,X Dec )Note2 ( Optional 57-56 Decimal, MSB First Date Code Week, Year )Note3 ( Optional 59-58 Character String (ASCII) Hardware Rev B01 & B02 Boards )Note4 ( 2 Characters 61-60 Decimal, MSB First Firmware Rev X,X,X,X Dec )Note5 ( 4 digits
62 U Integer, MSB First Reserved AA Hex
63 U Integer, MSB First Zero Checksum Value required to make the sum of bytes 0 to 62
added to a multiple of 256 Note: M2 = 20.48/65535 M3 = 80/65535 M4 = 20/65535 *Matching unit part number
Page 14 of 18 Oct 27, 2023 | Rev (g) | Doc: DS_M2192 Series M2192 Series– DC/DC Power Supply Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in Notes 1 to 5 Note 1: Part Number Example: M4465 Byte No ’ 32 33 34 35 36 37 38 51-39 Character M 4 4 6 5 )-( 4 0 Hex 4D 34 34 36 35 2D 34 00 Note 2: Serial Number Example: 25 Byte No ’ 52 53 54 55 NumberDec 0 0 0 0 0 0 2 5 Note 3: Date Code Example: week 35 of 2018 Byte No ’ 56 57 Dec Number 3 5 1 8 Note 4: Hardware Rev Example: B01 Rev (-), B01 Rev A Byte No ’ 58 59 Character )-( A Hex 2D 41 Note 5: Firmware Rev Example: 2.1.0.0 Byte No ’ 60 61 Dec Number 2 1 0 0
Page 15 of 18 Oct 27, 2023 | Rev (g) | Doc: DS_M2192 Series M2192 Series– DC/DC Power Supply Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in 8.2 46.11 Tier 2 Please see 46.11 User Manual for detailed information of operation. Sensors included are seen in the table below. Units are designed to be upgradable to 46.11 Tier 3 compliance upon release of that specification Record ID Sensor ID Sensor Type Name 0000 00 F0h FRU State Sensor 0001 01 F1h System IPMB Link Sensor 0002 02 F2h FRU Health Sensor 0003 03 02h FRU Voltage Sensor 0004 04 F3h FRU Temperature Sensor 0005 05 F4h Payload Test Results Sensor 0006 06 F5h Payload Test Status Sensor 0100 07 02h VS1 Voltage 0101 08 02h VoltageVS2 0106 0D 03h VS1 Current 0107 0E 03h VS2 Current 010C 13 01h Analog Temperature
9090 N/A N/A Device Locator Record
9999 N/A N/A Device Management
- Sync In and Switching Frequency The unit free running switching frequency while is 220KHz±5% Unit can be synchronized to External clock signal in frequency range of 200KHz to 300KHz External clock should be 3.3V CMOS standard logic level with duty cycle between 20% to 80%. The Internal clock will sync after 32, within tolerance, external clock cycles. Unit will revert to its internal clock upon any out of tolerance external clock and will require another 32 clocks to re synchronized. Note: Sync_in function is optional, please contact factory if required.
Page 16 of 18 Oct 27, 2023 | Rev (g) | Doc: DS_M2192 Series M2192 Series– DC/DC Power Supply Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in
Page 17 of 18 Oct 27, 2023 | Rev (g) | Doc: DS_M2192 Series M2192 Series– DC/DC Power Supply Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in Pin Assignments Pin Number Pin Name P1 -DC_IN P2 +DC_IN LP1 CHASSIS P3 VS1 P4 POWER_RETURN P5 POWER_RETURN LP2 3.3Vaux P6 VS1 A8 VS1_SENSE B8 3.3Vaux _SENSE C8 N.C (VS1_SENSE) D8 SENSE_RETURN A7 VS1_SHARE B7 3.3Vaux _ SHARE C7 VS1_ACS D7 Sig_RTN A6 SCL_B B6 SDA_B C6 N.C. D6 SYSRESET* A5 GA0* B5 GA1* C5 SCL_A D5 SDA_A A4 N.C. B4 N.C. C4 N.C D4 N.C A3 Sync_In / N.C. B3 N.C. C3 NED D3 )NED RETURN A2 N.C. B2 FAIL* C2 INHIBIT* D2 ENABLE* A1 N.C. B1 N.C C1 GA2* D1 3.3Vaux_ACS / N.C.
Page 18 of 18 Oct 27, 2023 | Rev (g) | Doc: DS_M2192 Series M2192 Series– DC/DC Power Supply Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in Outline Drawing Notes 1. Dimensions are in Inches[mm] 2. is Tolerance: .XX 0.02 IN .XXX 0.008 IN 3. Weight: Approx . 830g (29.28) oz 4. available 3D model * Specifications are subject to change without prior notice by the manufacturer.