Page 1 of 7 Nov 2, 2021 | Rev i | Doc: DS_M7028 Series M7028 DC/DC POWER SUPPLY Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in M7028 SERIES DC/DC POWER SUPPLY PRODUCT HIGHLIGHTS
- MINIATURE
- HIGH DENSITY
- SINGLE OUTPUT
- DC/DC POWER SUPPLY
- UP TO 200 W
Page 2 of 7 Nov 2, 2021 | Rev i | Doc: DS_M7028 Series M7028 DC/DC POWER SUPPLY Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in
Applications
Military (Airborne, ground-fix, shipboard), Ruggedized, Telecom, Industrial Power Supply Special Features
- Miniature size
- High efficiency
- High Density – up to 32.4 W/in³
- Wide input range
- Input / Output isolation
- Remote sense compensation
- Remote Inhibit (On/Off)
- Parallel connection (Option)
- Output voltage calibration (Option)
- Current limit calibration (Option)
- Fixed switching freq (250 kHz)
- External sync capability
- EMI filters included
- Non-latching protections: o Overload o Short circuit o Output Over Voltage o Over Temperature Electrical Specifications DC Input Voltage range: 18 to 48 VDC, IAW MIL-STD-704F No damage due to overvoltage transients IAW: MIL-STD-1275A (100 V for 50 ms) MIL-STD-704A (80 V for 0.1 s) DC Output Voltage range: 3.3 to 50 VDC Current range: 0 to 20 A Power range: 0 to 200 W Isolation Input to Output: 200 VDC Input to Case: 200 VDC Output to Case: 100 VDC Line/Load regulation Better than ±1% (no load to full load, –55 C to +85 C and over input voltage range). Efficiency Typical 86-87% - (at 28V full load, room temperature) EMC Designed to meet MIL-STD-461F* CE101, CE102, CS101, CS114, CS115, CS116, RE101, RE102, RS101, RS103 Ripple and Noise Less than 50 mVp-p, typical (max. 1%) without external capacitance. When connected to system capacitance ripple drops significantly. Transient Over-and-undershoot Output change at load transient of 30%-100% with Tr & Tf of max 30 μs is 5% of output voltage. Output recover to steady stated within less 0.5 ms. Turn on Transient No output voltage overshoot during power on. * Compliance achieved with 5μH LISN, shielded harness and static resistive load.
Page 3 of 7 Nov 2, 2021 | Rev i | Doc: DS_M7028 Series M7028 DC/DC POWER SUPPLY Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in Protections * Input
- Under Voltage Lockout Turn off below 15 VDC. Turn on above 16-18 VDC. UVLO hysteresis is approx. 2-3 V.
- Over Voltage Lockout Turn off above 52-55 VDC. Turn on below 48-51 VDC. Output
- Over Voltage Protection Active protection: Unit shuts down if output voltage rises 10% ± 5% above nominal voltage. Passive protection: Transorb selected at approx. 20% above nominal voltage.
- Current limiting Continuous protection (10-30% above maximum current) for unlimited time (Hiccup). General
- Over Temperature Protection Shutdown at base plate temperature of +105 C ± 5 C. Automatic recovery at base plate temperature lower than +95 C ± 5 C. Environmental Conditions Designed to Meet MIL-STD-810F Temperature Methods 501.4 & 502.4 Operating: –55 C to +85 C (at baseplate) Storage: –55 C to +125 C (ambient) Vibration Method 514.5 Procedure I Category 24 - General minimum integrity exposure Altitude Method 500.4 Procedures I – Storage/Air transport: up to 70 kft Procedure II – Operation/Air Carriage: up to 70 kft Shock Method 516.5 30 g, 11 ms terminal peak saw-tooth Humidity Method 507.4 Up to 95% RH Salt Fog Method 509.4 Reliability 150,000 hours, calculated IAW MIL-HDBK-217F Notice 2 at +85 C baseplate, Ground Fix conditions. Environmental Stress Screening (ESS) Including random vibration and thermal cycles is also available. Please consult factory for details. * Thresholds and protections can be modified / removed – please consult factory.
Page 4 of 7 Nov 2, 2021 | Rev i | Doc: DS_M7028 Series M7028 DC/DC POWER SUPPLY Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in Pin Assignment Connector: WTB30PR7J –D23 or eq. Mating connector options (Other options available - consult factory):
- Solder cup sockets: WTAX30SACJT# or eq.
- Removable crimp sockets: WTDXA30SJT# or eq. Pin No. Function Pin No. Function Pin No. Function
1 INPUT
11 OUTPUT
21 VLTG CAL
2 INPUT
12 OUTPUT RTN
22 SIGNAL RTN
3 INPUT RTN
13 OUTPUT RTN
23 SYNC IN
4 INPUT RTN
14 OUTPUT RTN
24 OUTPUT
5 PAR IN
15 SENSE
25 OUTPUT
6 PAR OUT
16 INPUT
26 OUTPUT
7 CRNT LMT CAL
17 INPUT
27 OUTPUT RTN
8 SYNC OUT
18 INPUT RTN
28 OUTPUT RTN
9 OUTPUT
19 INPUT RTN
29 OUTPUT RTN
10 OUTPUT
20 INHIBIT
30 SENSE RTN
Page 5 of 7 Nov 2, 2021 | Rev i | Doc: DS_M7028 Series M7028 DC/DC POWER SUPPLY Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in Functions and Signals INHIBIT signal The INHIBIT signal is used to turn the power supply ON and OFF. TTL “1” or OPEN – will turn on the power supply. (For normal operation leave the signal not connected.) TTL “0” or short– will turn off the power supply. SYNC IN signal The SYNC IN signal is used to allow the power supply frequency to sync with the system frequency. The system frequency should be 250 kHz ± 10 kHz. When not connected the power supply will work at 250 kHz ± 10 kHz. SYNC OUT signal The SYNC OUT signal is a buffered clock used to synchronize other units to the switching frequency of this unit. The signal amplitude is 12V. It is recommended to source and sink up to 1A on this pin. PAR IN signal The PAR IN signal is used to connect the power supply in parallel to other power supplies and have them almost equally divide the power between one another. All the power supplies should connect PAR IN signals together except the master unit where the PAR OUT signal connects to all the PAR IN signals. PAR OUT signal The PAR OUT signal is used to connect the power supply in parallel to other power supplies and have them almost equally divide the power between one another. The master unit connects the PAR OUT signals to all PAR IN pins of the slave units. VLTG CAL signal The VLTG CAL signal is used to control and adjust the output voltage of the power supply by up to ±5%. The calibration upwards is performed by connecting a resistor between this pin to SENSE pin. The calibration downwards is performed by connecting a resistor between this pin to SENSE RTN pin. Use a 1M Ω potentiometer set to full resistance and slowly decrease resistance until required output voltage reached. CRNT LMT CAL signal The CRNT LMT CAL signal is used to adjust the output current limit of the power supply. SIGNAL RTN The SIGNAL RTN is referred to the output. This is used as grounding for all signals. SENSE The SENSE is used to achieve accurate load regulations at load terminals (thi s is done by connecting the pins directly to the load’s terminals). The use of remote sense has a limit of voltage dropout between converter’s output and load terminals up to 0.5V. When not used connect + SENSE to +VOUT and –SENSE to –VOUT.
Page 6 of 7 Nov 2, 2021 | Rev i | Doc: DS_M7028 Series M7028 DC/DC POWER SUPPLY Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in Outline Drawing Heat Dissipation Surface Notes 1. Dimensions are in inches [mm] 2. Tolerance is: .XX ± 0.02 in .XXX ± 0.008 in 3. Weight: Approx. 6.4 oz [180 g]
Page 7 of 7 Nov 2, 2021 | Rev i | Doc: DS_M7028 Series M7028 DC/DC POWER SUPPLY Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in Standard Configurations Part number Input voltage range Output Voltage Output Current M7028-100 18 to 48 VDC 5 VDC 20 A M7028-101 18 to 48 VDC 12 VDC 16 A M7028-102 18 to 48 VDC 15 VDC 13 A M7028-103 18 to 48 VDC 24 VDC 8 A M7028-104 18 to 48 VDC 28 VDC 7 A M7028-105 18 to 48 VDC 48 VDC 4 A Note: Specifications are subject to change without prior notice by the manufacturer.