Page 1 of 9 Jun 4, 2023 | Rev n | Doc: DS_M4244 Series M4244 SERIES DC/DC POWER SUPPLY Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in M4244 SERIES DC/DC POWER SUPPLY PRODUCT HIGHLIGHTS
- MINIATURE
- HIGH DENSITY
- HIGH EFFICIENCY
- SINGLE OUTPUT
- DC/DC POWER SUPPLY
- UP TO 500 W
Page 2 of 9 Jun 4, 2023 | Rev n | Doc: DS_M4244 Series M4244 SERIES DC/DC POWER SUPPLY Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in Electrical Specifications DC Input Voltage range: 18 to 70 VDC Normal surge (operational) IAW MIL-STD-1275A-D and MIL-STD-704A-F. MIL-STD-1275E option. Abnormal surge (no damage) IAW MIL-STD-1275A-D (100 V for 50 ms) and MIL-STD-704A-F (80 V for 0.1 s) DC Output Voltage range: 3.3 to 400 VDC Current range: 0 to 30 A Power range: 0 to 500 W Output voltage regulation Less than ±1% (no load to full load, –55C to +85C and over normal input voltage range). Ripple & Noise Less than 50mVp-p, typical (max. 1%) without external capacitance. When connected to system capacitance ripple drops significantly. Isolation – Low voltage version Input to Output: 200 VDC Input to Case: 200 VDC Output to Case: 200 VDC Isolation – High voltage version Input to Output: 500 VDC Input to Case: 200 VDC Output to Case: 500 VDC EMC Designed to meet* MIL-STD-461F CE101, CE102, CS101, CS114, CS115, CS116, RE101, RE102, RS101, RS103 Transient over-and-undershoot Output resistance at load change of 50% to 100% is 30 to 120 mΩ (depending on output voltage). Output returns to steady-state value within 300 to 500µs Efficiency Typically, 80 to 85% (28VDC or 270VDC output, full load, nominal input voltage, room temperature) Turn-on transient No Voltage overshoot during power on. * EMC compliance achieved when tested with 5 μH LISNs, shielded harness and static resistive load.
Applications
Military (ground-fix, shipboard), Ruggedized, Telecom, Industrial Special Features
- Miniature size
- High efficiency
- Wide input range
- Input / Output Isolation
- Voltage Sense Compensation
- Fixed switching freq. (250 kHz)
- External sync. capability
- Sync. out capability
- Remote Inhibit
- EMI filters included
- Non-latching automatic recovery protections: o Short-circuit o Over-voltage o Over temperature
Page 3 of 9 Jun 4, 2023 | Rev n | Doc: DS_M4244 Series M4244 SERIES DC/DC POWER SUPPLY Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in Reliability 150,000 hours, calculated IAW MIL-HDBK-217F Notice 2 at +85 C baseplate, Ground Fixed environment. Notes: * Thresholds and protections can be modified / removed – please consult factory. Protections * Input
- Under-Voltage Lock-Out Unit shuts down below 16.5VDC ± 1V.
- Over-Voltage Lock-Out Unit shuts down above 75VDC ± 3V. Output
- Active Over-Voltage Protection Internal control shuts output voltage down if it exceeds 110% ± 5% of nominal voltage.
- Passive Over-Voltage Protection Transorb assembled across the output pins, selected at 120% ± 10% of nominal voltage. General
- Over Temperature Protection Unit shuts down if baseplate temperature rises above +105C ± 5C. Automatic recovery when baseplate temperature falls below +95C ± 5C.
- Under-Voltage Protection Internal control shuts output voltage down (hiccup) if falls below 85% ± 5% of nominal voltage.
- Current Limiting Continuous protection (10-30% above maximum current) for unlimited time (Hiccup). Environmental Conditions Designed to meet MIL-STD-810F Temperature Operating: –55 C to +85 C (at baseplate) Storage: –55 C to +125 C Altitude Method 500.4 Procedures I & II – Up to 33 kft. Higher altitude option. Salt Fog Method 509.4 Humidity Method 507.4 Procedure I Up to 95% RH Vibration (random) Method 514.5 Category 4 - General minimum integrity exposure IAW Figure 514.5C-17 1 hour per axis. Shock Method 516.5 Procedure I 20 g, 11 ms terminal peak saw- tooth,
Page 4 of 9 Jun 4, 2023 | Rev n | Doc: DS_M4244 Series M4244 SERIES DC/DC POWER SUPPLY Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in Typical Efficiency Curves
270 VDC output version:
28 VDC output version:
Page 5 of 9 Jun 4, 2023 | Rev n | Doc: DS_M4244 Series M4244 SERIES DC/DC POWER SUPPLY Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in Pin Assignment † J1 - Input Connector Type: M24308/24-39F or eq. Mates with: M24308/2-3F or eq. Pin # Function P Pin # Function P Pin # Function P
1 INPUT +
10 CHASSI
S
19 INPUT RTN –
2 INPUT +
11 SYNC IN +
20 INPUT RTN –
3 INPUT +
12 INHIBIT
21 INPUT RTN –
4 INPUT +
13 SIGNAL
RTN –
22 INPUT RTN –
5 N.C. 14 INPUT + 23 N.C.
6 INPUT RTN –
15 INPUT +
24 INHIBIT
7 INPUT RTN –
16 INPUT +
25 SYNC
8 INPUT RTN –
17 INPUT +
9 INPUT RTN –
18 N.C. J2 - Output Connector Type: M24308/23-38F or eq. Mates with: M24308/4-2F or eq. Pin # Function P Pin # Function Pin # Function P
1 OUTPUT +
6 OUTPUT RTN –
11 OUTPUT +
2 OUTPUT +
7 OUTPUT RTN –
12 N.C.
3 OUTPUT +
8 N.C. 13 OUTPUT RTN – 4 N.C.
9 OUTPUT +
14 OUTPUT RTN –
5 OUTPUT RTN –
0 OUTPUT +
15 OUTPUT RTN –
† All pins with identical function/designation should be connected together for best performance.
Page 6 of 9 Jun 4, 2023 | Rev n | Doc: DS_M4244 Series M4244 SERIES DC/DC POWER SUPPLY Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in Functions and Signals INHIBIT IN The INHIBIT signal is used to turn the power supply ON and OFF. TTL “1” or OPEN – Power supply active (output turned on). TTL “0” or SHORT to Signal RTN – Power supply inhibited (output turned off). If this function is not required, leave this pin unconnected. INHIBIT OUT Used when connecting two units or more in parallel. Connect this signal to the INHIBIT IN pi n of the slave unit (see diagram below). This signal synchronizes the shutdown and startup of the units. SYNC IN signal The SYNC IN signal is used to allow the power supply frequency to sync with the system frequency. The system frequency can be 250 kHz ± 10 kHz. When not connected the power supply will work at 250 kHz ± 10 kHz. SYNC OUT signal The SYNC OUT signal is used to sync the system and / or other power supplies with the power supply's frequency. SIGNAL RTN The SIGNAL RTN is referred to the input. This pin is used as a return path for SYNC IN, SYNC OUT and INHIBIT IN.
Page 7 of 9 Jun 4, 2023 | Rev n | Doc: DS_M4244 Series M4244 SERIES DC/DC POWER SUPPLY Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in Typical Connection Diagram Single converter operation Input Voltage INPUT (+) INPUT RTN (-) Inhibit In Signal Return Sync In Sync Out Inhibit Out OUTPUT (+) OUTPUT RTN (-) Load Short = Off Open = On External Clock 250 kHz ± 10 kHz M4244 Parallel connection operation Input Voltage INPUT (+) INPUT RTN (-) Inhibit In Signal Return Sync In Sync Out Inhibit Out OUTPUT (+) OUTPUT RTN (-) Load Short = Off Open = On External Clock 250 kHz ± 10 kHz M4244 Input Voltage INPUT (+) INPUT RTN (-) OUTPUT (+) OUTPUT RTN (-) Load M4244 Inhibit In Signal Return Sync In Sync OutInhibit Out Note: The total regulation (line + load + temperature) is ±2% of nominal voltage.
Page 8 of 9 Jun 4, 2023 | Rev n | Doc: DS_M4244 Series M4244 SERIES DC/DC POWER SUPPLY Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in Outline Drawing Heat Dissipation Surface Notes 1. Dimensions are in inches [mm] 2. Tolerance is: .XX 0.01 in .XXX 0.005 in 3. Weight: Approx. 25.5 oz [725 g] Dissipation Area 9.23 in² [5,954.8 mm²]
Page 9 of 9 Jun 4, 2023 | Rev n | Doc: DS_M4244 Series M4244 SERIES DC/DC POWER SUPPLY Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in Standard Configurations Part Number Input Output Special features Voltage range Voltage Current M4244-100 18 to 70 VDC 12 VDC 30 A M4244-101 18 to 70 VDC 15 VDC 30 A M4244-102 18 to 70 VDC 24 VDC 20 A M4244-103 18 to 70 VDC 28 VDC 17 A M4244-104 18 to 70 VDC 48 VDC 10.5 A M4244-105 18 to 70 VDC 270 VDC 1.8 A M4244-107 18 to 70 VDC 270 VDC 1.8 A Parallel operation via output voltage droop. Voltage regulation is ±2%. Note: Specifications are subject to change without prior notice by the manufacturer