Page 1 of 7 Jan 7, 2022 | Rev (e) | Doc: DS_M4162 Series M4162 Series– DC/DC HOLDUP UNIT Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in M4162 SERIES DC/DC HOLDUP UNIT PRODUCT HIGHLIGHTS
- VITA 62 COMPLIANT
- 3U FORM FACTOR
- WIDE INPUT RANGE
- IPMI / 46.11 COMMUNICATION
- UP to 48J
Page 2 of 7 Jan 7, 2022 | Rev (e) | Doc: DS_M4162 Series M4162 Series– DC/DC HOLDUP UNIT Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in Electrical Specifications DC Input Up to 100VDC Continuous work during MIL-STD- 704 transients Communication IPMI / 46.11 protocol available for voltages DC Output VS1: Power VS2: Power return Normally: Input Follower During Power loss: Output is Up to 85V Efficiency Typical 98% Isolation Over 20 MΩ at test voltage: 200V between Input & output to case EMC Complies with MIL-STD-461F (5µH LISN): CE101, CE102, CS101 Environmental Salt Fog: Method 509.5 Shock Method 516.6 40g, 11msec saw- tooth (all directions) Normal Quiescent Current: Charging Current: 15A Maximum Normal Operation: 0.1A Design to Meet MIL-STD-810G Temperature Operating: –55°C to +85°C at unit edge Storage: –55°C to +125°C Altitude Method 500.5, Procedure I & II Storage/Air Transport: 40 kft Operation/Air carriage: 70 kft Fungus Humidity Does not support fungus growth, in Method 507.5, Up to 95% RH accordance with the guidelines of MIL- STD-454, Requirement 4. Vibration Shock: Saw-tooth, 20g peak, 11mS. Vibration: Figure 514.6E-1. General minimum integrity exposure. (1 hour per axis.) Reliability 239,210 Hours, calculated IAW, MIL-HDBK-217F Notice 2 at +85 ℃, GF (Max Holdup). Note: Environmental Stress Screening (ESS) Including random vibration and thermal cycles is also available. Please consult factory for details. Protections Input
- Inrush Current Limiter Peak value of 5 x IIN for initial inrush currents lasting more than 50µSec.
- Under Voltage Unit shuts down when input voltage drops below 11± 0.5VDC. Automatic restart when input voltage returns to 12V Line. General
- Over Temperature Protection Automatic shutdown at internal temperature of 95 ± 5°C. Automatic recovery when temperature drops below 90 ±5°C. Note: Thresholds and protections can be modified/removed (please consult factory)
Page 3 of 7 Jan 7, 2022 | Rev (e) | Doc: DS_M4162 Series M4162 Series– DC/DC HOLDUP UNIT Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in Normal Operation: During Normal Operation, the M4162 works as an Input follower. Small Voltage drop, of less than 1V is expected Hold Up Operation: When Voltage at the input of the unit, drops below 18V, the Holdup will discharge it’s internal capacitance into the DC Bus. During this time the M4162 output voltage will rise up to 85V and will decrease as the capacitor bank energy will be discharging. Recharging of the capacitor bank will start before Input voltage goes back to steady state line. The M4162 charging time is less than 0.5Sec per Mil-STD-704, during this time, the average charging current taken from the source can be calculated as follow 𝐸 = 𝐶 ∗ 𝑉𝑐2 𝐼 = 𝐸 𝑉𝑖𝑛 ∗ 𝑡 ∗ 𝐸𝑓𝑓 Where E is Holdup Energy, Vc and C are the Holdup capacitance and charging voltage, Vin is input voltage and Eff is the charging circuit efficiency. For specific details contact Factory. Reducing Charging current and increasing charge time is optional. Functions and Signals - According to VITA 62 Signal No. Signal Name Type Description Pin No’ Power Down Output Indicates that Holdup event has occurred. Open Drain. Normally Open, goes low during Holdup time. Power Ready Output Indicates to other modules that Holdup capacitor bank is Fully charged. Open Drain. Normally Open, goes low when Holdup energy under 90%. GA0, GA1 Input Used for geographical addressing. GA1 is the most significant bit and GA0 is the least significant bit. A5,B5 SCL, SDA Bidirectional I2C bus Clock and Data respectively. Through this bus the voltage and temperature readouts can be shared. C5,D5
Page 4 of 7 Jan 7, 2022 | Rev (e) | Doc: DS_M4162 Series M4162 Series– DC/DC HOLDUP UNIT Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in Simplified Block Diagram Typical Application
Page 5 of 7 Jan 7, 2022 | Rev (e) | Doc: DS_M4162 Series M4162 Series– DC/DC HOLDUP UNIT Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in Pin Assignment Pin Number Pin Name P1 -DC_IN P2 +DC_IN LP1 CHASSIS P3 N.C. P4 N.C. P5 N.C. LP2 Bus_RTN P6 Bus A8 N.C. B8 N.C. C8 N.C. D8 N.C. A7 N.C. B7 N.C. C7 N.C. D7 Sig_RTN A6 SCL_B B6 SDA_B C6 N.C. D6 N.C. A5 GA0* B5 GA1* C5 SCL_A D5 SDA_A A4 N.C. B4 N.C. C4 N.C D4 N.C A3 Power_Ready B3 N.C. C3 N.C. D3 N.C. A2 N.C. B2 N.C. C2 N.C. D2 N.C. A1 N.C. B1 N.C C1 N.C. D1 Power_Down
Page 6 of 7 Jan 7, 2022 | Rev (e) | Doc: DS_M4162 Series M4162 Series– DC/DC HOLDUP UNIT Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in
Page 7 of 7 Jan 7, 2022 | Rev (e) | Doc: DS_M4162 Series M4162 Series– DC/DC HOLDUP UNIT Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in Outline Drawing Notes: 1. Dimensions are in inches [mm] 2. Tolerance is: .XX ± 0.02 IN .XXX ± 0.008 IN 3. Weight: Approx. TBD 4. 3D model available Note: Specifications are subject to change without prior notice by the manufacturer.