M4050 ENERCON | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 12

Technical content

Page 1 of 12 Oct 26, 2021 | Rev i | Doc: DS_M4050 Series M4050 SERIES VPX VITA 62 POWER SUPPLY Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in M4050 SERIES DC/DC POWER SUPPLY PRODUCT HIGHLIGHTS

  • 3U, 0.8 PITCH, VITA 62 COMPLIANT
  • FAST INITIALIZATION TIME
  • 5 OUTPUTS
  • OPTIONAL EXTENSION FOR HOLDUP CARD
  • 150W

Page 2 of 12 Oct 26, 2021 | Rev i | Doc: DS_M4050 Series M4050 SERIES VPX VITA 62 POWER SUPPLY Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in Electrical Specifications DC Input 16 to 36 VDC Max Non-Operating 100V Options: 1) MIL-STD-704 (A-F) Normal and Abnormal Steady State 2) MIL-STD-704(A-F) transients Up to 50V, 80V 3) MIL-STD-1275 100V Surge DC Output VS1: 12V/2A VS2: 3.3V/15A VS3: 5V/12A 3.3V_Aux: 3.3V/1A -12V_Aux: 12V/1A Isolation 500V between Input and Output 500V between Input and Case 500V between Output and Case Line/Load regulation Less than 1% for 12V & 5V Outputs 1.5% for 3.3V outputs (No load to full load, –55C to 90C) Efficiency Up to 85 % (Full load room temperature) EMC Complies with MIL-STD-461F (5µH LISN): CE101, CE102, CS101, CS114, CS115, CS116 Ripple and Noise Typically less than 50mVp-p(max. 1%p). Measured across a 0.1μF capacitor and 10μF capacitor on load at input voltage of 18V-36V, across the whole temperature range. Load Transient Overshoot and Undershoot Output dynamic response of less than 5% at load Step of 30%-90%. Output returns to regulation in less than 1mSec System Management I2C/IPMI protocol available for voltages, currents and temperature for all voltages (GAx, SCL, SDA) Environmental 1 Design to Meet MIL-STD-810G Temperature Operating: –55°C to +90°C at unit edge¹ Storage: –55°C to +125°C Altitude Method 500.5, Procedure I & II Storage/Air Transport: 40 kft Operation/Air carriage: 70 kft Salt Fog: Method 509.5 Fungus Does not support fungus growth, in accordance with the guidelines of MIL- STD-454, Requirement 4. Humidity Method 507.5, Up to 95% RH Shock Vita 47 Level ECC4 Vibration Shock: Saw-tooth, 40g peak, 11mS. Vibration: Figure 514.6E-1. General minimum integrity exposure. (1 hour per axis.) Reliability: 225,900 Hours, calculated IAW MIL-HDBK-217F Notice 2 at +45℃, AUC. Note 1: 90°C at 50% Load

Page 3 of 12 Oct 26, 2021 | Rev i | Doc: DS_M4050 Series M4050 SERIES VPX VITA 62 POWER SUPPLY Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in Protections 1 Input

  • Inrush Current Limiter Peak value of 5 x IIN for initial inrush currents lasting more than 50µSec.
  • Under Voltage Unit shuts down when input DC voltage drops below 15.3± 0.5VDC. Automatic restart when input voltage returns to nominal range.
  • Over Voltage Lock-Out Unit shuts down when input voltages rise above 55 ± 2VDC. Automatic restart when input voltage returns to nominal range. Output
  • Passive over voltage protection on Aux outputs Transorb, selected at 25% ± 5% above nominal voltage, is placed across the output for passive voltage limit.
  • Active over voltage protection on VS# outputs 20% ± 5% above nominal voltage. Automatic recovery when output voltage drops below threshold.
  • Overload / Short-Circuit Protection Continuous protection (10-30% above maximum current) for unlimited time (Hiccup). Automatic recovery when overload / short circuit removed. General
  • Over Temperature Protection Automatic shutdown at internal temperature of 95 ± 5°C. Automatic recovery when temperature drops below 90 ± 5°C. Note 1: Thresholds and protections can be modified / removed – please consult factory)

Page 4 of 12 Oct 26, 2021 | Rev i | Doc: DS_M4050 Series M4050 SERIES VPX VITA 62 POWER SUPPLY Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in Functions and Signals - According to VITA 62 Signal No. Signal Name Type

Description

FAIL* Output Indicates to other modules in the system that a failure has occurred in one of the outputs or Input line is under 17V. Normally Open, Low during failure. SYSRESET* Output Indicates to other modules in the system that all outputs are within their working level. Normally Open, Low during failure. INHIBIT* Input Combined with ENABLE, controls power supply outputs. Please refer to Table 1. Signal has Internal Pullup see picture 1. Do not tied the signal to unit 3.3V or 3.3VAux ENABLE* Input Combined with INHIBT, controls power supply outputs. Please refer to Table 1. Signal has Internal Pullup see picture 1. GA0*, GA1* Input Used for geographical addressing. GA1 is the most significant bit and GA0 is the least significant bit. SCL, SDA Bidirectional I2C bus Clock and Data respectively. Through this bus the voltage and temperature readouts can be shared. Alert Bit Output Open Drain output, goes low when Input voltage drops below 17V

8 VOUT SENSE Input The SENSE is used to achieve accurate load regulations at load terminals

(this is done by connecting the pins directly to the load’s terminals). 9 Signal RTN Gnd Signal ground for all signal. Internally tied to output Power ground INHIBIT* Low Low High High ENABLE* Low High Low High Outputs Status OFF OFF ON OFF Table 1: Inhibit & Enable functionality. Figure 1: Inhibit & Enable Input Stage.

Page 5 of 12 Oct 26, 2021 | Rev i | Doc: DS_M4050 Series M4050 SERIES VPX VITA 62 POWER SUPPLY Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in Simplified Block Diagram

Page 6 of 12 Oct 26, 2021 | Rev i | Doc: DS_M4050 Series M4050 SERIES VPX VITA 62 POWER SUPPLY Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in Detailed Information 1. Input Voltage Operation. The Power supply steady state operation voltage is 18V to 36V and will continuously work at input voltages up to 50V and down to 16V. During transients or surges above 50V or below 16V for more than 50uSec the unit will shut down. Automatic recovery occurs when input line drops down below 48V.

1.1 Low Line Turn-on and Turn-off Limits

To avoid turn-on and turn-off glitches, the unit has about 3.5V hysteresis. The turn-on threshold is under 20V and turn- off under 16V. These limits can be adjusted, contact factory for more information. 2. Outputs regulation The unit contains accurate internal sense lines to keep output voltage at less than 1.5% regulation for all Line/ Load and temperature range (see Table 2). Output 12V/2A 5V/12A 3.3V/15A 3.3VAux 12VAux (-)12VAux/1A Voltage Table 2: Single Unit 2.1.1. Sense Lines Sense Lines are provided for VS1, VS2 and VS3 output to compensate line voltage drop. Sense Lines proper connection is shown in Figure 2. Each VSx output has its own Sense Lines, additional common Sense RTN Line is provided for all VSx Outputs (VITA 62 Standard). Contact Factory for Sense configuration different than the VITA 62 Standard Figure 2: Sense line connection Vout Sense VSx Output Power RTN Sense Load Vout Sense VSx Output Power RTN Sense Load

Page 7 of 12 Oct 26, 2021 | Rev i | Doc: DS_M4050 Series M4050 SERIES VPX VITA 62 POWER SUPPLY Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in

3.0 Output Signals

All discrete signals are referred to Signal RTN.

3.1 FAIL*

FAIL* – Indicates a failure in one of the Outputs or Input line is under 17V. Output which is turned off by Enable or Inhibit, will not be considered as a Fail. Signal Normally Open.

3.2 SYSRESET*

SYSRESET* – Indicates that all Outputs are in or above their nominal range. Signal Normally Open. See Figure 3. Figure 3

3.3 ALERT

ALERT – Indicates that Input voltage is under 17V, will go back high above 18V. Signal Normally Open.

Page 8 of 12 Oct 26, 2021 | Rev i | Doc: DS_M4050 Series M4050 SERIES VPX VITA 62 POWER SUPPLY Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in 4. I²C Protocol I2C Software Version 1.2 – support I2C (IPMI protocol is optional) Electrical Parameters Vcc: 3.3VDC Pull-up: 2.0kOhm Input capacitance: 330pf Slave Device Addressing - 16 address spaces - Baud rate: 200kHz maximum - 7 Bit Address - Support Slot Addressing per VITA 62 - Support Global Address 1010101 R/W MSB LSB Slot Number A6 A5 A4 A3 A2 A1/*GA1 A0/*GA0 R/W Slot0 0 1 0 0 0 0 0 Slot1 0 1 0 0 0 0 1 Slot2 0 1 0 0 0 1 0 Slot3 0 1 0 0 0 1 1 Global Address 1 0 1 0 1 0 1 * Slot location is determined by GAx per VITA 62. Communications Supported Single read sequence S Physical Address W A Memory Address A S Physical Address R A DAT A A P A6:A0 0 0 B7:B0 0 A6:A0 1 0 D7:D0 1 Sequential read sequence S Physical Address W A Memory Address A S Physical Address R A DAT A A DAT A A

  • • • DAT A A P A6:A0 0 0 B7:B0 0 A6:A0 1 0 D7:D0 0 D7:D0 0 D7:D0 1 S – Start, P- Stop W – Write bit A – Acknowledge by master A – Acknowledge by slave, DATA – Slave response

Page 9 of 12 Oct 26, 2021 | Rev i | Doc: DS_M4050 Series M4050 SERIES VPX VITA 62 POWER SUPPLY Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in SDA Timeout Reset The Uart SDA Line is default “Open” unless data is transmitted by the slave. As a second level precaution the FPGA has a separate VHDL entity which sense the FPGA’s SDA Line and forced it open in case it detects a 150mSec duration of “Low” SDA Line. The line will be released back to normal once the entity will detect a new attempt of UART communication. Memory Byte # Data Type Meaning Interpretation Reading Range

0 S Integer, MSB First Temperature T(Cᵒ)=+/-7bit Dec Note1 -55 Cᵒ to 125 Cᵒ

1 U Integer, MSB First Input Voltage Not applicable 00 Hex

2 U Integer, MSB First 12V VS1 Voltage V(out) = Data/ m2 Note2 0 to 20.48V 3 U Integer, MSB First 3.3V VS2 Voltage V(out) = Data/ m2 0 to 20.48V 4 U Integer, MSB First 5V VS3 Voltage V(out) = Data/ m2 0 to 20.48V

5 U Integer, MSB First 12V Aux Voltage Not applicable 00 Hex

6 U Integer, MSB First (-)12V Aux Voltage V(out) =(-) Data/ m2 0 to 20.48V 7 U Integer, MSB First 3.3V Aux Voltage V(out) = Data/ m2 0 to 20.48V

8 U Integer, MSB First 12V VS1 Current Not applicable 00 Hex

9 U Integer, MSB First 3.3V VS2 Current Not applicable 00 Hex

10 U Integer, MSB First 5V VS3 Current Not applicable 00 Hex

11 Binary Fail Bit & SysReset Bit 0000 , 00 Fail, SysReset

00000,00xx 12-13 Character String(ASCII) Unit version Rev X,Y Note4 2 Characters 14-15 Character String(ASCII) Firmware Version Version A.B Note3 2 Characters 16-19 Character String(ASCII) Part Number 4050 4 Characters Note1: Temperature = Reading (Dec). MSB=’1’ for negative numbers. Note2: m2= 20.48/255. Vout = (Reading / 255) * 20.48 [V] Note3: Example: Firmware Version 2.3 32 Hex, 33 Hex Note 4: Example: Unit Version 0A 30, 41 Note5: Fail & SysReset are the last two bits of the Byte 11. ‘1’ signal is good, ‘0’ signal Fail. “0000, 00 Fail Bit, SysReset Bit”

Page 10 of 12 Oct 26, 2021 | Rev i | Doc: DS_M4050 Series M4050 SERIES VPX VITA 62 POWER SUPPLY Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in Pin Assignment

Page 11 of 12 Oct 26, 2021 | Rev i | Doc: DS_M4050 Series M4050 SERIES VPX VITA 62 POWER SUPPLY Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in Pin Assignment Pin Number Pin Name P1 -DC_IN P2 +DC_IN LP1 CHASSIS P3 VS3 P4 POWER_RETURN P5 POWER_RETURN LP2 VS2 P6 VS1 A8 VS1_SENSE B8 VS2_SENSE C8 VS3_SENSE D8 SENSE_RETURN A7 VS1_SHARE / N.C B7 VS2_SHARE / N.C C7 VS3_SHARE / N.C D7 SiG_RTN A6 N.C B6 N.C C6 -12V_AUX D6 SYSRESET* A5 GA0* B5 GA1* C5 SCL D5 SDA A4 +3.3V_AUX B4 +3.3V_AUX C4 +3.3V_AUX D4 +3.3V_AUX A3 Alert BIT B3 +12V_AUX C3 N.C D3 N.C A2 N.C B2 FAIL* C2 INHIBIT* D2 ENABLE* A1 N.C B1 N.C C1 N.C D1 Alert BIT

Page 12 of 12 Oct 26, 2021 | Rev i | Doc: DS_M4050 Series M4050 SERIES VPX VITA 62 POWER SUPPLY Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in Outline Drawing Note: Specifications are subject to change without prior notice by the manufacturer.