M333-4 ENERCON | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 5
Technical content
Page 1 of 5 Oct 12, 2023 | Rev f | Doc: DS_M333-4 Series M333-4 BATTERY PACK Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in * For ordering Part Number: see Page 5 M333-4 RACK-MOUNTED BATTERY PACK PRODUCT HIGHLIGHTS 108VDC, 10AH External Battery Pack, Used with M362-4 UPS
- VERY LONG HOLDUP TIME:
2 HRS @ 1KW AND 1 HR @ 2KW
(WITH FOUR M333-4 BATTERY PACKS)
- USES HIGH QUALITY VRLA CELLS
- COMPLIES WITH MIL-STD-167-1 (TYPE I) AND MIL-S-901D
Page 2 of 5 Oct 12, 2023 | Rev f | Doc: DS_M333-4 Series M333-4 BATTERY PACK Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in The main features of the M333-4 are: ➢ Standard 19” Rack Mounted, 2U high, and 22” deep with slides and rear-panel load- bearing bushings. ➢ Up to (4) four M333-4 Units can be connected and controlled by a single M362-X UPS. ➢ Supports very long Holdup time; over 2 hours at 1KW and one hour at 2KW (with four M333-4 Battery Packs). ➢ An ID Resistor allows the Host UPS (M362-X) to automatically identify the type and number of Battery Packs connected to it. ➢ Internal Electronic Switch removes power from the I/O connectors when not connected to the Host UPS or when the UPS is Off. ➢ Complies with MIL-STD-167-1 (Type I) and MIL-S-901D Shipboard Shocks and Vibration. ➢ MS Power Connectors. ➢ J-STD-001B and IPC-610A Class-3 Workmanship. ➢ Conformal Coating of PWBs per MIL-I-46058C and IPC-CC-830. ➢ Uses high quality VRLA cells.
Page 3 of 5 Oct 12, 2023 | Rev f | Doc: DS_M333-4 Series M333-4 BATTERY PACK Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in Specifications: Battery Type Valve regulated Lead-Acid (Yuasa NPX-25 or equivalent). Nominal Voltage 108VDC Nominal Capacity 10AH (10hr) Output (AC) Power 1KW 1.8KW 2.4KW Hold-up Time (Vs. Load on the M362-X Output) at 25°C. Notes 1 and 2 With one M333-4 26 min 13 min 9.5 min With two M333-4 60 min 30 min 21 min With three M333-4 96 min 48 min 34 min With four M333-4 134 min 67 min 48 min Notes: 1. For other loads between 1KW to 2.4KW the Hold-up time can be estimated using the following formula: Holdup Time(minutes) = 26.5 x (N/KW)1.17 were KW is the load in KW and N is the number of M333-4 units connected to the UPS. 2. Below 25°C, derate by 1.25% for every 1°C. INDICATIONS & CONTROLS Front panel Visual Indication A Green LED indicates that the Battery Pack is connected to an operating UPS. Safety Switch When the Host UPS is turned Off, or the “Safe to Disconnect” push button on the UPS (M362-X) front panel is depressed, or the cable between the UPS to the Battery Pack is disconnected, power is automatically removed from the I/O connectors of the M333-4. ENVIRONMENT Temperature Non-operating: -20 to +70C Operating: 0 to + 55C Note: Prolong exposure to temperatures above +40°C will degrade the battery expected life and performances. Humidity Up to 95% (MIL-STD-810F, Method 507.4). Altitude Operating: Up to 10,000 feet. Non-operating: (Air transport) 50,000 feet. Orientation May be installed at any orientation. Mechanical Shock MIL-S-901D (Grade A, Class I &2) Vibration Shipboard Vibration Per MIL-STD-167-1 (Type 1) Fungus Does not support fungus growth, in accordance with the guidelines of MIL-STD-454, Requirement 4. Acoustic Noise Less than 28dBA (no fans or any other moving parts are used). EMI MIL-STD-461E CS114, (Curve 5, Bulk Cable Injection), CS115 (Bulk Cable Injection), RE101, RE102, RS101, RS103. (Surface-Ships and Submarine-Internal application). DC Magnetic Field Tolerates 1600 A/m (per MIL-STD-1399 Section 70) WEIGHT and SIZE In accordance with DWG M333004 (19” Rack-mount, 2U high, 22” deep, weighs 100 Lbs)
Page 4 of 5 Oct 12, 2023 | Rev f | Doc: DS_M333-4 Series M333-4 BATTERY PACK Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in Connectors and Pin Out: Notes: 1. Caution !!! When the M333-4 is connected to an operating UPS, high voltage (120VDC) may appear on J2. To avoid safety hazard J2 should never be left open. If unused, it must be sealed by its tethered protection cap. 2. Up to (4) four M333-4 units can be connected to a single M362-X UPS. 3. For proper operation, all pins of J1 and J2 must be connected. 4. If more than one M333-4 is used, connect the units as shown below. The wire size is the minimum required. All pins will accept up to AWG #16. The total cables length between the last M333-4 to the UPS should not exceed 9 feet. J1 – TO UPS (To the M362-X UPS) MS3452W20-27P or Eq Des. Signal Minimum Wire Size A GND AWG #16 B IDRES-2 AWG #22 C TMPSNS-1 AWG #22 D TMPSNS-2 AWG #22 E +BATT AWG #16 F +BATT AWG #16 G +24VDC AWG #22 H BATT-RTN AWG #16 I BATT-RTN AWG #16 J Reserved AWG #22 K 24VDCRTN AWG #22 L IDRES-1 AWG #22 M +BATT AWG #16 N BATT-RTN AWG #16 J2 – TO NEXT BATT (To additional M333-4 BATT Pack) MS3452W20-27S or Eq Des. Signal Minimum Wire Size A GND AWG #16 B IDRES-2 AWG #22 C Reserved AWG #22 D Reserved AWG #22 E +BATT AWG #16 F +BATT AWG #16 G +24VDC AWG #22 H BATT-RTN AWG #16 I BATT-RTN AWG #16 J Reserved AWG #22 K 24VDCRTN AWG #22 L IDRES-1 AWG #22 M +BATT AWG #16 N BATT-RTN AWG #16 M333-4 M333-4 M333-4 M362-X UPS CAP
Page 5 of 5 Oct 12, 2023 | Rev f | Doc: DS_M333-4 Series M333-4 BATTERY PACK Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in How to Order Basic Part Number Special Options -0 None (Std.) Optional Slides & Load Bearing Pins -0 None (Std.) -1 Pins and Slides: Pins: Jonathan P/N 1005-406 or equivalent (mate with the UPS back panel’s bushings) Slides: Actron P/N A5520-23 (or eq.) -2 Pins only (same as -1). Optional Special Hardware -0 None (Std.) Order PN: M333-4 - 0 - 0 - 0 Note: Specifications are subject to change without prior notice by the manufacturer.