M286 ENERCON | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 8

Technical content

Page 1 of 8 Sep 5, 2021 | Rev (l) | Doc: DS_M286 Series M286 Series– AC/DC Power Supply Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in M286 SERIES

1.5 KW AC TO DC BASEPLATE COOLED POWER

The M286 is a series of mechanically robust, base plate cooled, high performance, 1.5kW AC to DC power supplies, designed for Navy shipboard applications. The M286 converts a 3-Phase 115/200VAC, 50/60Hz source or 3-Phase (3-lines), 115/200VAC, 400Hz Per MIL-STD-704F to a well regulated, filtered and protected DC Output.

Page 2 of 8 Sep 5, 2021 | Rev (l) | Doc: DS_M286 Series M286 Series– AC/DC Power Supply Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in STANDARD CONFIGURATIONS * Additional standard configurations available. Contact factory for more details. * All of our products can be configured to comply with EU REACH regulations. Contact factory for more details. Part number Input Output Voltage range Frequency Voltage Current M286-100 ACphase, 104 to 127 V-3 50/60Hz 12 VDC 54 A M286-101 ACphase, 104 to 127 V-3 50/60Hz 15 VDC 54 A M286-102 3-phase, 104 to 127 VAC 50/60Hz 24 VDC 54 A M286-103 3-phase, 104 to 127 VAC 50/60Hz 28 VDC 54 A M286-104 3-phase, 104 to 127 VAC 50/60Hz 36 VDC 41.6 A M286-105 3-phase, 104 to 127 VAC 50/60Hz 48 VDC 31.25 A

Page 3 of 8 Sep 5, 2021 | Rev (l) | Doc: DS_M286 Series M286 Series– AC/DC Power Supply Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in THE MAIN FEATURES OF THE M286 ARE: ➢ AC/DC Single output power supply up to 1.5kW ➢ High Density ➢ Input range: 104-127VAC | 50/60Hz 3-Phase ➢ Can parallel units for more power ➢ EMI filters included ➢ High efficiency ➢ Full galvanic isolation between Input, Chassis and Outputs. ➢ External Inhibit (On/Off) ➢ Indefinite short circuit protection with auto-recovery ➢ Over-voltage shutdown with auto-recovery ➢ Over temperature shutdown with auto-recovery ➢ Remote sense compensation ➢ Conduction cooled via the baseplate ➢ J-STD-001B and IPC-610A Class-3 workmanship ➢ Conformal Coating per MIL-I-46058C and IPC-CC-830

Page 4 of 8 Sep 5, 2021 | Rev (l) | Doc: DS_M286 Series M286 Series– AC/DC Power Supply Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in SPECIFICATIONS AC Input Type 3-Phase (3-lines), 115/200VAC, 400Hz Per MIL-STD-704F. Note: The M286 will operate and provide full performances when fed by a 270VDC source (per MIL-STD-704F) or by a 3-Phase 115/200VAC, 50/60Hz source (except that the input power factor will be lower). Voltage Range Steady State: 104 to 127VAC (180 to 215Vac Line-to-Line) Transients: up to 180Vac/50mS (per Figures 3 and 4 of MIL-STD-704F). During voltage transient (per Figure 3 of MIL-STD-704E) the output voltage may deviate by -15% +5% from the regulation range, but will recover within 50mS. Will also accept a +270VDC input. Frequency 45 to 450Hz (will also operate from a 270VDC source). Input Power Factor 0.85 Minimum (at full load and 115VAC/400Hz input). Missing Phase The M286 will not be damaged by a missing phase, but may shutdown. Automatic recovery within 1.5 Sec after input recovery. DC Output Nominal Voltage 28DC Rated Current 54Amp Regulation (Using the Sense Lines) ±1.5Vdc (worst case combination of steady state load, line and temp.) Note: In order to facilitate current sharing when several M286 are paralleled, the output voltage exhibits a controlled slop of 1.3Vdc from 0% to 100% the load near to the Remote Sense connection. Can be set, upon request, to lower or higher voltage). Remote Sense Capable of up to 3VDC line drop (round trip) compensation. When left open, the point of regulation shifts to the output connector. Current Limit & Overload Protection Output current internally limited to less than 125% of the full rated current. If an over-load pulls the output voltage below 14Vdc for more than 100mS, the output is disabled and will attempt to recover after 1 second. The recovery attempts (100mS On, 1 sec Off) will continue until the overload is removed. Ripple and noise Less than 300mVpp (measured with BW of 20MHZ on any resistive load between 2 to 54Amp and any capacitance between 1 to 10,000µF. Below 2Amp the ripple may rise to 1.5 Vpp. Overvoltage Protection In case of an internal failure that causes the output voltage to exceed 32.2±0.5V, the output will shut down. (Externally imposed voltage will not trip the protection). Recovery upon toggling the AC input or the INHIBIT Input. Over Temp. Protection Automatic shutdown when the Base Plate exceeds 90°C. Automatic recovery when the heatsink temperature drops below 80°C.

Page 5 of 8 Sep 5, 2021 | Rev (l) | Doc: DS_M286 Series M286 Series– AC/DC Power Supply Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in INHIBIT Input Open-collector (or low-level switch) Low (V < 3.5V @ 6mA, relative to RTNVout) inhibits the Output. Open (I < 1mA @ 12V) enables the Output. BIT Output Opto-coupler (Open-collector) Low (V < 0.8 @ 1mA, relative to RTNBIT) means Normal Operation. Open (I < 0.1mA @ 15V) means Failure to Operate. Isolation Input to Chassis GND 20MΩ (Min) at 500Vdc. Input to Output and BIT 20MΩ (Min) at 500Vdc. Output to Chassis GND 20MΩ (Min) at 200Vdc. BIT to Output & Chassis GND 20MΩ (Min) at 200Vdc EMI Designed to meet ҂ MIL-STD-461E CE102, CS101, CS114, CS115, CS116, RE102 and RS103. Cooling Base Plate User should maintain the M286’s Base Plate below 85°C by thermally attaching it to a suitable coldplate (heatsink). Temperature & Altitude Operating -50°C to +70°C, 40,000 feet. Non-operating -55°C to +80°C. Up to 40,000 feet. Vibration Operating and Non-operating MIL-STD-810F , Method 514.5C, Figure 514-5C-17 Mechanical Shock Operating and Non-operating Sow-tooth, 40g peak, 11mS (3 shocks in each 6 orthogonal directions). Humidity Operating and Non-operating Up to 100% RH (including condensation). Salt-fog Operating and Non-operating MIL-STD-810F, Method 509-4.

Page 6 of 8 Sep 5, 2021 | Rev (l) | Doc: DS_M286 Series M286 Series– AC/DC Power Supply Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in PIN ASSIGNMENT J1 – AC Input D38999/20WD5PN or Eq. Pin Fucntion A 115VAC Phase A (or +270VDC) B 115VAC Phase B (or RTN270VDC) C 115VAC Phase C (not used with DC Input) D NC E Chassis (Safety) GND J2 – DC Output D38999/20WE35SN or Eq. Pin Fucntion Pin Fucntion Pin Fucntion

1 Chassis GND 20 +Vout 39 RTN Vout

2 Inhibit 21 RTN Vout 40 +Vout

3 Reserved 22 RTN Vout 41 +Vout

4 Remote Sense (+) 23 RTN Vout 42 +Vout

5 Remote Sense (-) 24 NC 43 RTN Vout

6 +Vout 25 +Vout 44 RTN Vout

7 RTN Vout 26 +Vout 45 RTN Vout

8 BIT 27 +Vout 46 RTN Vout

9 RTN BIT 28 RTN Vout 47 +Vout

10 +Vout 29 RTN Vout 48 +Vout 11 +Vout 30 RTN Vout 49 +Vout 12 +Vout 31 RTN Vout 50 RTN Vout

13 RTN Vout 32 +Vout 51 RTN Vout

14 RTN Vout 33 +Vout 52 RTN Vout

15 RTN Vout 34 +Vout 53 +Vout

16 NC 35 +Vout 54 +Vout

17 +Vout 36 RTN Vout 55 RTN Vout 18 +Vout 37 RTN Vout 19 +Vout 38 RTN Vout

Page 7 of 8 Sep 5, 2021 | Rev (l) | Doc: DS_M286 Series M286 Series– AC/DC Power Supply Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in TYPICAL CONNECTION DIAGRAM M286-28 A AWG#16 B AWG#16 C AWG#16 E AWG#16 From 115VAC/ 3-Ph Source (200VAC Line-to-Line) Safety Ground (4) RMT SNS (+) (5) RMT SNS (-) (2) Inhibit (8) BIT (9) RTNBIT 23x AWG#22 23x AWG#22 +28VDC RTN28VDC Small Signal Switch 3.3/5Vcc 10KΩ 0.01µF Notes: 1. For effective remote sensing at full load (54Amp), the output cable length should not exceed 20 feet. 2. For best EMC performances use shielded cables. 3. The INHIBIT Switch can be a small-signal mechanical switch or an electronic switch (Small-signal Transistor). 4. To inhibit (disable) the 28VDC output, the low side of the switch (emitter for NPN, source for N-MOS) should be connected to the RTN28VDC. 5. RTNBIT may be connected to any Logic GND (not necessarily RTN28VDC). 6. When paralleling several M286, for best performances: Connect all AC Inputs (J1) to the same AC Source. Connect all +Vout and all RMT SNS (+) lines to the same point (+28VDC Point Of Regulation). Connect all RTNVout and all RMT SNS(-) lines to the same point (RTN28VDC Point Of Regulation). The Inhibit lines may be connected to a single or several switches. Each BIT should have its own pull-up and gate interface. (1) Chassis GND Chassis (optional) GND Shield Shield Logic GND (TTL/CMOS) LOAD AWG#22 AWG#22 AWG#22 AWG#22 AWG#22 AWG#22