Features
LO/RF 7.0 to 26.5 GHz IF DC to 8.0 GHz 6.0 dB Typical Conversion Loss 38 dB Typical LO to RF Isolation Broadband RF and LO For a list of recommended LO driver amps for all mixers and IQ mixers, see here. Electrical Specifications - Specifications guaranteed from -55 to +100C, measured in a 50-Ohm system. Parameter LO RF IF Min Typ Max Diode Option (GHz) (GHz) (GHz) LO drive level (dBm) Isolation (dB) LO-RF 7.0-26.5 7.0-26.5 25 38 Input 1 dB Compression (dBm) 7.0-26.5 7.0-26.5 +2 L (+8 to +11) +5 M (+11 to +14) +8 N (+14 to +17) Input Two-Tone Third Order Intercept Point (dBm) +15 M (+11 to +14) +18 N (+14 to +17) Part Number Options Please specify diode level and package style by adding to model number. Package Style(s)1 Example R, S, Z M1R-0726 L R 1Connectorized test fixtures available for most carrier and surface mount packages. Consult factory. Marki Microwave reserves the right to make changes to the product(s) or information contained herein without not ice. Marki Microwave makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor does Marki Mi crowave assume any liability whatsoever arising out of the use of or application of any product.
Copyright © [2016, 2020] Marki Microwave, Inc. All Rights Reserved. DOUBLE-BALANCED MIXERS M1R-0726 Page 2 LO/RF 7.0 to 26.5 GHz IF DC to 8.0 GHz Typical Performance 1:1 2:1 3:1 RF Port VSWR2:1 3:1 LO Port VSWR LO to RF Isolation - dB 2.0 3.0 1.0 Relative IF Response - dB 9.0 7.0 5.0 Conversion Loss - dB Ref 7.0 GHz 26.57.0 GHz 26.5 7.0 GHz 26.5 DC GHz 8.07.0 GHz 26.5 4:1 LO to IF Isolation - dB 7.0 GHz 26.550 DATA SHEET NOTES: 1. Mixer Conversion Loss Plots IF frequency is 100 MHz. 2. Mixer Noise Figure typically measures within +0.5 dB of conversion loss for IF frequencies greater than 5 MHz. 3. Conversion Loss typically degrades less than 0.5 dB for LO drives 2 dB below the lowest and 3 dB above highest nominal LO drive levels. 4. Conversion Loss typically degrades less than 0.5 dB at +100°C and improves less than 0.5 dB at -55°C. 5. Maximum input power is+23 dBm at +25°C, derated linearly to +20 dBm at +100°C. 6. Specifications are subject to change without notice. Contact Marki Microwave for the most recent specifications and data sheets. 7. Catalog mixer circuits are continually improved. Configuration control requires custom mixer model numbers and specifications. Marki Microwave reserves the right to make changes to the product(s) or information contained herein without notice. Marki Microwave makes no warranty, representation, or guarantee regarding the suitability of its products for any particular purpos e, nor does Marki Microwave assume any liability whatsoever arising out of the use or application of any product. www.markimicrowave.com