File Name: M1981cat Rev D Date: 2017/04/20 Page 1 of 5 Enercon Technologies Ltd 31 Yad Harutsim St., Netanya, Israel

Applications

Military (Airborne, ground-fix, shipboard), Ruggedized, Telecom, Industrial Special Features

  • Miniature size
  • High efficiency
  • Wide input range
  • High power factor (0.98)
  • Input / Output isolation
  • Inrush Current Limiter
  • External On/Off Inhibit
  • Fixed switching freq. (250 kHz)
  • External synchronization capability
  • EMI filters included
  • Indefinite short circuit protection with auto-recovery
  • Over-voltage shutdown with auto-recovery
  • Over temperature shutdown with auto-recovery Electrical Specifications AC Input: 85 to 265 VAC, 50/60/400 Hz, single-phase per MIL-STD-704A & per MIL-STD-1399:300A (60Hz) DC Output: Output range – 3.3V to 48V Output power – 200W (peak 250W) Output current – max 20A Isolation: 1000V between Input and Output 1000V between Input and Case 200V between Output and Case Line/Load regulation: Less than 1% (no load to full load, –55°C to +85°C). Efficiency : Up to 80% - Typical (full load, room temperature) EMC: Designed to meet MIL-STD- 461D: CE101, CE102, CS101, CS114, CS115, CS116, RE101, RS101, RS103 Ripple and Noise: 100÷150mVp-p, typical (max. 1%) without external capacitance. Load Transient Overshoot and undershoot Current change from 50%-100% output voltage change less than 0.5V within 200-300µSec Turn on Transient Voltage overshoot at during power on is less than 3% nominal voltage. M1981 SERIES AC/DC CONVERTERS HIGH DENSITY, HIGH POWER FACTOR SINGLE PHASE, SINGLE OUTPUT UP TO 200W A&D&CO19(57(5

File Name: M1981cat Rev D Date: 2017/04/20 Page 2 of 5 Enercon Technologies Ltd 31 Yad Harutsim St., Netanya, Israel Protections * Input

  • Inrush Current Limiter peak value of 5 x IIN for inrush currents lasting more than 50µSec.
  • Under Voltage Lock-Out Unit shuts down below 75VAC ± 5VAC. Output
  • Active Overvoltage Protection Internal control protects unit 5- 15% above nominal voltage.
  • Passive Overvoltage Protection 10-30% above nominal voltage.
  • Current limiting Continuous protection (10-30% above maximum current) for unlimited time (Hiccup). General
  • Over temperature protection: Shuts down if base plate temp exceeds +105°C ± 5°C. Automatic recovery when base plate temperature drops below +95°C ± 5°C. * Thresholds and protections can be modified / removed – please consult factory. Environmental Designed to Meet MIL-STD-810F Temperature: Operating: –40°C to +85°C (base plate) Storage: –55°C to +125°C Humidity: Method 507.4 - Up to 95%. Altitude: Method 500.4, Procedure I & II, 40,000 ft. and 70,000 ft. Operational Vibration and Shock: Shock - Saw-tooth, 20g peak, 11mS. Vibration - Figure 514.5C-17, General minimum integrity exposure. (1 hour per axis.) Salt Fog: Method 509-4 Reliability ~143,000 hours, calculated per MIL-STD-217F Change Notice 2 at +85°C base plate, Ground Fixed. Environmental Stress Screening (ESS) Including random vibration and thermal cycles is also available. Please consult factory for details. A&D&CO19(57(5

File Name: M1981cat Rev D Date: 2017/04/20 Page 3 of 5 Enercon Technologies Ltd 31 Yad Harutsim St., Netanya, Israel Pin Assignment Option A: with external synchronization, without sense lines. Pin No. Function Pin No. Function Pin No. Function

1 OUT RTN (–) 10 PHASE 19 N/C

2 OUT RTN (–) 11 N/C 20 SYNC RTN

3 N/C 12 NEUTRAL 21 INHIBIT RTN

4 OUT (+) 13 NEUTRAL 22 N/C

5 OUT (+) 14 OUT RTN (–) 23 PHASE

6 N/C 15 OUT RTN (–) 24 N/C

7 SYNC 16 N/C 25 CHASSIS

8 INHIBIT 17 OUT (+)

9 N/C 18 OUT (+)

O ption B: with sense lines, without external synchronization. Pin No. Function Pin No. Function Pin No. Function

2 OUT RTN (–) 11 N/C 20 SENSE RTN (–)

7 SENSE (+) 16 N/C 25 CHASSIS

Note: All pins with the identical function or designation should be connected together for best performance. A&D&CO19(57(5

File Name: M1981cat Rev D Date: 2017/04/20 Page 4 of 5 Enercon Technologies Ltd 31 Yad Harutsim St., Netanya, Israel Functions and Signals SENSE The SENSE line is used to achieve accurate voltage regulation at load terminals. To use this feature, connect this pin directly to load's positive terminal. If this function is not required, short SENSE pin to OUTPUT pins as close as possible to the unit. SENSE RTN The SENSE RTN line is used to achieve accurate voltage regulation at load terminals. To use this feature, connect this pin directly to load's negative terminal. If this function is not required, short SENSE RTN pin to OUTPUT RTN pins as close as possible to the unit. Note: The use of remote sense has a limit of voltage dropout between the converter's output and the load's terminals of approximately 5% of nominal output voltage. INHIBIT The INHIBIT signal is used to turn the power supply ON and OFF. TTL “1” or OPEN – Power supply active (output turned on). TTL “0” or SHORT to Signal RTN – Power supply inhibited (output turned off). If this function is not required, leave this pin unconnected. SYNC The SYNC signal is used to synchronize the power supply's switching frequency to system 's clock. Valid external clock frequency is 250kHz ±10kHz. If this function is not required, leave this pin unconnected - the power supply will use its internal clock. CHASSIS The CHASSIS pin allows additional connection of unit's chassis to system ground. Typical Connection M1981 AC In Return (-) VOUT (+) VOUT Load Input Voltage Inhibit (-) Sense (+) Sense Chassis Inhibit Return Inhibit (Optional) (Optional) Sync Sync Return Inhibit AC In A&D&CO19(57(5

File Name: M1981cat Rev D Date: 2017/04/20 Page 5 of 5 Enercon Technologies Ltd 31 Yad Harutsim St., Netanya, Israel Outline Drawing Heat Dissipation Surface pecifications are subject to change without prior notice by the manufacturer. Notes 1. Dimensions are in inches [mm] 2. Tolerance is: .XX ± 0.01 in .XXX ± 0.005 in 3. Weight: Approx. 23 Oz [650 g] 4. Parasolid 3D module is available Dissipation Area 7.585 in² (5070 mm²) A&D&CO19(57(5