Page 1 of 10 Jun 14, 2021 | Rev (c) | Doc: DS_M1912 Series M1912 Series– AC/DC Power Supply Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in M1912 SERIES 300W Dual Output AC to DC Baseplate Cooled Power Supply PRODUCT DESCRIPTION The M1912 is a series of mechanically robust, base plate cooled, high performance, 300W dual output AC to DC power supplies, for Navy shipboard, Airborne, and ground applications. The M1912 converts 115VAC – 230VAC/50- 60Hz or 115VAC 400Hz, to a well-regulated, filtered and protected main DC Output 280W and Auxiliary output 20W. The product meet MIL-STD requirements (specified herein).

Page 2 of 10 Jun 14, 2021 | Rev (c) | Doc: DS_M1912 Series M1912 Series– AC/DC Power Supply Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in STANDARD CONFIGURATIONS Part number Input Main Output Aux Output ON/OFF Logic Voltage range Frequency Voltage Current Voltage Current M1912-100 Single-phase, 85 to 265 VAC 50/60/400 Hz 12 VDC 20 A 3.3 VDC 5 A Enable M1912-101 Single-phase, 85 to 265 VAC 50/60/400 Hz 12 VDC 20 A 3.3 VDC 5 A Inhibit M1912-102 Single-phase, 85 to 265 VAC 50/60/400 Hz 12 VDC 20 A 5 VDC 3.3 A Enable M1912-103 Single-phase, 85 to 265 VAC 50/60/400 Hz 12 VDC 20 A 5 VDC 3.3 A Inhibit1 M1912-104 Single-phase, 85 to 265 VAC 50/60/400 Hz 24 VDC 12A 3.3 VDC 5 A Inhibit1 M1912-106 Single-phase, 85 to 265 VAC 50/60/400 Hz 24 VDC 12A 5 VDC 3.3 A Inhibit1 M1912-108 Single-phase, 85 to 265 VAC 50/60/400 Hz 24 VDC 12A 12 VDC 1.5 A Inhibit1 M1912-110 Single-phase, 85 to 265 VAC 50/60/400 Hz 28 VDC 10A 3.3 VDC 5 A Inhibit1 M1912-112 Single-phase, 85 to 265 VAC 50/60/400 Hz 28 VDC 10A 5 VDC 3.3 A Inhibit1 M1912-114 Single-phase, 85 to 265 VAC 50/60/400 Hz 28 VDC 10A 12 VDC 1.5 A Inhibit1 M1912-116 Single-phase, 85 to 265 VAC 50/60/400 Hz 48 VDC 5.5A 3.3 VDC 5 A Inhibit1 M1912-118 Single-phase, 85 to 265 VAC 50/60/400 Hz 48 VDC 5.5A 5 VDC 3.3 A Inhibit1 M1912-120 Single-phase, 85 to 265 VAC 50/60/400 Hz 48 VDC 5.5A 12 VDC 1.5 A Inhibit1

  • Note: 1Enbale logic is available - Contact factory for more details.
  • Additional standard configurations available. Contact factory for more details.
  • All of our products can be configured to comply with EU REACH regulations. Contact factory for more details.
  • For CE MARKING (IEC 62368-1) configuration - Contact factory for more details.

Page 3 of 10 Jun 14, 2021 | Rev (c) | Doc: DS_M1912 Series M1912 Series– AC/DC Power Supply Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in MAIN FEATURES ➢ AC/DC Dual output power supply up to 300W ➢ Single phase input (50/60/400Hz) ➢ Withstands MIL-STD-1399-300B 1,000 V spikes ➢ Complies with MIL-STD-461F for shipboard application ➢ Complies with MIL-STD-167-1 (Type I) shipboard vibration ➢ Robust mechanical design, intended for systems that should withstand MIL-DTL-901E high impact shocks ➢ High power factor (Full load PF of above 0.9) ➢ Main output 12V to 48V @ Max 280W ➢ Aux. output 3.3V to 12V @ Max 20W ➢ High efficiency ➢ Full galvanic isolation between Input, Chassis and Outputs. ➢ Inrush Current Limiter ➢ External Inhibit (On/Off) ➢ Fixed switching freq. (250 kHz) ➢ EMI filters included ➢ Remote sense compensation for Auxiliary output ➢ Indefinite short circuit protection with auto-recovery ➢ Over-voltage shutdown with auto-recovery ➢ Over temperature shutdown with auto-recovery ➢ High density ➢ Conduction cooled via the baseplate ➢ J-STD-001B and IPC-610A Class-3 workmanship ➢ Conformal Coating per MIL-I-46058C and IPC-CC-830

Page 4 of 10 Jun 14, 2021 | Rev (c) | Doc: DS_M1912 Series M1912 Series– AC/DC Power Supply Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in SPECIFICATIONS AC Input Voltage and Frequency Option 1: 85 to 265 VAC ; 50/60Hz Single-phase, 5A max IAW MIL-STD-1399-300B, Type I (115 Vrms / 60 Hz) Option 2: 103 to 127 VAC ; 400Hz Single-phase, 5A max Under Voltage shutdown Unit protects itself (no damage) below 75 VAC @ full load. Inrush Current Limiter Initial input current surge to charge internal capacitances is limited internally. Isolation Input to Output: 1000 VDC Input to Case: 1000 VDC Note: Tested during production, at system level the test Voltage limited to 250V since internal TVS installed between Neutral to Chassis for surge protection. If this feature not required, please consult factory. DC Output Output Range Voltage Range Current Power Main Output 12V to 48V Up to 20A Up to 280W AUX Output 3.3V to 12V Up to 5A Up to 20W Main output and Auxiliary output are not isolated from each other. Additional configuration available. Consult factory for details. Voltage Regulation Less than 1% (no load to full load, –40 C to +85 C) For voltage output below 5V, Less than 3% (no load to full load, –40 C to +85 C) Remote Sense AUX SENSE The AUX SENSE line is used to achieve accurate voltage regulation at load terminals. To use this feature, connect this pin directly to load's positive terminal. If this function is not required, short AUX SENSE pin to AUX OUTPUT pins as close as possible to the unit. AUX SENSE RTN The AUX SENSE RTN line is used to achieve accurate voltage regulation at load terminals. To use this feature, connect this pin directly to load's negative terminal. If this function is not required, short SENSE RTN pin to OUTPUT RTN pins as close as possible to the unit. Note: The use of remote sense has a limit of voltage dropout between the converter's output and the load's terminals of approximately ±0.5V of nominal output voltage. Turn on Overshoot Output voltage overshoot during power on < 5% Ripple and noise For Vout>5V typical max 1% For Vout< 5V typical max 2% With 1μF external capacitance. Isolation Output to case: 200 VDC

Page 5 of 10 Jun 14, 2021 | Rev (c) | Doc: DS_M1912 Series M1912 Series– AC/DC Power Supply Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in Current Limit & Overload 10 - 30% above maximum current, indefinitely (Hiccup). Efficiency

115 Vrms / 400 Hz ≥ 80%

230 Vrms / 50 Hz ≥ 84%

(Typical @ 250W load) Overvoltage Protection

  • Active Over Voltage Protection 10% ± 2% above nominal voltage.
  • Passive Over Voltage Protection Transorb/Zener at output selected 20% ± 5% above nominal voltage. Over Temp. Protection Shutdown at base plate temp. above +105C ± 5 C Automatic recovery at base plate temp. below +95C ± 5C. Control & Indication ON/OFF Input The ENABLE/ INHIBIT signal is used to turn the power supply ON and OFF. The internal pullup voltage is 3.3V typical and the IPULLDOWN (the minimum current to RTN needed to turn on the PSU) is 3mA Typical. Table 1 – Inhibit and Enable Functionality Enable logic Inhibit logic 'ON' V < 0.8V – P.S 'ON' or Enable = 'SHORT' – P.S 'ON' V > 2.4V – P.S 'ON' or Inhibit = 'OPEN' – P.S 'ON' 'OFF' V > 2.4V – P.S 'OFF' or Enable = 'OPEN' – P.S 'OFF' Inhibit = 'SHORT' – P.S 'OFF' or V < 0.8V – P.S 'OFF' The ENABLE/ INHIBIT signal is floating form output return. Optional to applied 28V between Inhibit pin to signal RTN to active the power supply (output turned on)- Please consult factory. SIGNAL RTN This signal is used as grounding for ENABLE/INHIBIT signal. Signal RTN is isolated from output. Environment Temperature MIL-STD-810F, Methods 501.4 & 502.4 Operating: –40C to +85C (at baseplate) Storage: –55C to +125C (ambient) Optional: Operating -55C to +85C (at baseplate). Consult factory for details. Humidity MIL-STD-810F, Method 507.4 Up to 95% RH Salt-fog MIL-STD-810F, Method 509.4 Altitude MIL-STD-810F, Method 500.4 Procedures I – Storage/Air transport: up to 70,000 ft. (non-operational) Procedure II – Operation/Air Carriage: up to 40,000 ft. (operational)

Page 6 of 10 Jun 14, 2021 | Rev (c) | Doc: DS_M1912 Series M1912 Series– AC/DC Power Supply Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in Mechanical Shock MIL-STD-810F , Method 516.5,

  • Procedure I -Functional shock, 40g, 15 -23 ms, Terminal Peak, Sawtooth shock pulse
  • Procedure V - Crash Hazard, 40g, 15 -23 ms, Terminal Peak, Sawtooth shock pulse MIL-S-901D: Withstands the high-impact shipboard shock IAW MIL-S-901D, Grade A, Class I and II Vibration MIL-STD 810F, Method 514.5, Procedure I, Category 24, General minimum integrity exposure, IAW Figure 514.5C-17, 1 hour per axis. Type I vibration IAW MIL-STD-167-1A Fungus Does not support fungus growth (MIL-STD-810G, Method 508.6) EMC Designed to meet MIL-STD-461F Conducted Emission CE101, CE102 Conducted Susceptibility CS101, CS114, CS115, CS116 Radiated Emission RE101, RE102 Radiated Susceptibility RS101, RS103 * All tests are at full load and in accordance with the provisions of MIL -STD-461F – with shielded Output and Signals cables. EN/IEC Radiated Emission Conducted Emission EN55032 CLASS A Harmonic current Emission IEC6100-3-2 CLASS A Voltage Fluctuation & Flicker IEC6100-3-3 Immunity Test (EN/IEC) Test Type Test Method Test Type/Level/Class ESD EN61000-4-2 Enclosure; Contact; ±4Kv; [B] Radiated Immunity EN61000-4-3 (80-6000) MHz; 10V/m; [A] EFT EN61000-4-4 ±2kV; [B] Surge EN61000-4-5 L-L: ±1kV; [B] L-E: ±2kV; [B] Conducted Immunity EN61000-4-6 150kHz – 80MHz ; 10Vrms; [A] Magnetic Field EN61000-4-8 50Hz; 30A/m; [A] Voltage dips and short interruptions Cooling Requirements The M1912 is a baseplate cooled unit. The base of the M1912 should be thermally attached to a suitable heatsink that maintains it below +85 °C.

Page 7 of 10 Jun 14, 2021 | Rev (c) | Doc: DS_M1912 Series M1912 Series– AC/DC Power Supply Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in OPERATIONAL BLOCK DIAGRAM Form factor 119.4 mm wide, 30 mm high and 177.8 mm deep. The base should be mechanically and thermally attached to a user provided coldplate (see Page 9 and 10). For detailed dimensions and tolerances see Drawing: M1912-100 Weight 1150g (Typical) Reliability 150,000 hours, calculated IAW MIL-HDBK-217F Notice 2 at +65C baseplate, Ground fixed conditions.

Page 8 of 10 Jun 14, 2021 | Rev (c) | Doc: DS_M1912 Series M1912 Series– AC/DC Power Supply Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in PIN ASSIGNMENT J1 – AC Input connector J2 – DC Output connector Type: Positronic CBM3W3M550000 OR EQ. Type: HDC25S50000-15 OR EQ. Mates with: Positronic CBM3W3S00000 FC4016D-15 (X3) – #16 CRIMP CONTACTS Mates with: M24308/4-3Z OR EQ. Pin Fucntion Pin Fucntion Pin Fucntion A1 NEUTRAL 1 AUX SENSE RTN 14 AUX SENSE A2 PHASE 2 SIGNAL RTN 15 N/A A3 CHASSIS * 3 ENABLE/ INHIBIT 16 AUX OUTPUT

4 AUX OUTPUT 17 OUTPUT RTN

5 OUTPUT RTN 18 OUTPUT RTN

6 OUTPUT RTN 19 OUTPUT RTN

7 OUTPUT RTN 20 OUTPUT RTN

8 OUTPUT RTN 21 OUTPUT RTN

9 OUTPUT RTN 22 OUTPUT

10 OUTPUT 23 OUTPUT

11 OUTPUT 24 OUTPUT

12 OUTPUT 25 OUTPUT

13 OUTPUT

  • The CHASSIS pin allows additional connection of unit's chassis to system ground. TYPICAL CONNECTION DIAGRAM M1912 Output Output RTN AUX Sense RTN ENABLE / INHIBITSIGNAL RTN Neutral Phase Load Enable/ INHIBIT Input Voltage Load Aux Sense AUX OUTCHASSIS

Page 9 of 10 Jun 14, 2021 | Rev (c) | Doc: DS_M1912 Series M1912 Series– AC/DC Power Supply Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in OUTLINE DRAWING

Page 10 of 10 Jun 14, 2021 | Rev (c) | Doc: DS_M1912 Series M1912 Series– AC/DC Power Supply Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in OUTLINE DRAWING (Cont.)

  • These figures are for reference only. For more details, please contact us. Note: Specifications are subject to change without prior notice by the manufacturer