Page 1 of 7 Oct 20, 2022 | Rev (k) | Doc: DS_M186 Series M186 SERIES THREE-PHASE AC/DC POWER SUPPLY Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in M186 SERIES THREE-PHASE AC/DC POWER SUPPLY PRODUCT HIGHLIGHTS
- COMPACT
- HIGH EFFICIENCY
- HIGHT DENSITY
- SINGLE OUTPUT
- THREE PHASE AC/DC POWER SUPPLY
- UP TO 2000 W
Page 2 of 7 Oct 20, 2022 | Rev (k) | Doc: DS_M186 Series M186 SERIES THREE-PHASE AC/DC POWER SUPPLY Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in
Applications
Military Power Supply (Airborne, ground-fix, shipboard), Ruggedized, Telecom, Industrial Power Supply Special Features
- Miniature size
- High efficiency
- Wide input range
- High density: up to 30.5 W/in³
- Input / Output isolation
- Limited Inrush Current
- Remote Inhibit (On/Off)
- Fixed switching freq. (400 kHz)
- EMI filters included
- Cos φ > 0.92 from 75% load
- Non-latching protections: o Output overload o Output short-circuit o Output over-voltage o Over temperature Electrical Specifications Normal Input Voltage AC variant voltage range: 115 10% VAC,L-N,
400 Hz, 3-Phase
Optional for 50/60Hz Input frequency: Please consult factory for details. DC Output: Voltage range: 5 to 60 VDC Current range: 0 to 80 A Power range: 0 to 2 000 W Isolation Input to Output: 500 VDC Input to Case: 500 VDC Output to Case: 100 VDC Line/Load regulation Up to ±1% (no load to full load, –55 C to +85 C and over input voltage range). Efficiency 90% - Typical (nominal line voltage, 28 VDC output, full load, standard room temperature) EMC Designed to meet MIL-STD- 461F**: CE102, CS101, CS114, CS115, CS116, RE102, RS101, RS103 Ripple and Noise 100 to 150 mVp-p, typical (max. 1% of nominal voltage) measured across a 1μF ceramic capacitor. Transient Over-and-undershoot Voltage change less than 10% of nominal value for load step from 50% to 100%. Return to regulation in under 1 ms. Turn on Transient No Voltage overshoot during turn on. Protections * Input
- Inrush Current Limiter Up to 6 times the maximum input current for less than 50 µs. Output
- Over-voltage Protection Passive transorb on output, 120% ± 10% of nominal voltage.
- Current limiting Continuous protection (10 to 30% above maximum current) for unlimited time. General
- Over temperature protection Shutdown at baseplate temperature of +105 C 5 C. Automatic recovery at base plate temperature lower than +95 C 5 C. * Thresholds and protections can be modified / removed – please consult factory. ** Depending on configuration, an external filter may be required to comply with EMI requirements.
Page 3 of 7 Oct 20, 2022 | Rev (k) | Doc: DS_M186 Series M186 SERIES THREE-PHASE AC/DC POWER SUPPLY Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in Environmental Conditions Designed to Meet MIL-STD-810F Temperature Methods 501.4 & 502.4 Operating: –55C to +85C (at baseplate) Storage: –55C to +125C (ambient) Vibration Method 514.5 Procedure I, Category 24 General minimum integrity exposure IAW Figure 514.5C-17 1 hour per axis. Altitude Method 500.4 Procedure I – Storage/Air transport: up to 70,000 ft. (non-operational) Procedure II – Operation/Air Carriage: up to 40,000 ft. (operational) Shock Method 516.5 Procedure I 20 g / 11 ms terminal peak sawtooth shock pulse Humidity Method 507.4 Up to 95% RH Salt Fog Method 509.4 Reliability 100,000 hours, calculated IAW MIL-HDBK-217F Notice 2 at +85 C baseplate, Ground fixed conditions.
Page 4 of 7 Oct 20, 2022 | Rev (k) | Doc: DS_M186 Series M186 SERIES THREE-PHASE AC/DC POWER SUPPLY Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in Pin Assignment Connector type: M24308/24-39F or eq. Mating connector type M24308/2-3F or eq. Pin No. Description 4, 5, 17 PHASE A 7, 8, 20 PHASE B 10, 11, 23 PHASE C 15 + SENSE † 2 - SENSE †
14 INHIBIT
1 SIGNAL RTN
25 CHASSIS
† Please inform factory if sense lines are required to be tied to the output from within, or if the remote sense compensation function will be used.
Page 5 of 7 Oct 20, 2022 | Rev (k) | Doc: DS_M186 Series M186 SERIES THREE-PHASE AC/DC POWER SUPPLY Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in Functions and Signals INHIBIT The INHIBIT signal is used to turn the power supply ON and OFF. OPEN – will turn on the power supply. SHORT – between pin 14 and pin 1 will turn off the power supply. This signal is referenced to the SIGNAL RTN pin. SENSE The SENSE is used to achieve accurate load regulations at load terminals (this is done by connecting the pins directly to the load’s terminals). The use of remote sense has a limit of voltage dropout between converter’s output and load terminals of 2-10% of voltage output (up to 2V). Please note that if Sense lines are not used the output may rise as much as 2V above nominal outputs. Typical Connection Diagram M186 Phase A Phase C (-) VOUT (+) VOUT Load Input Voltage Inhibit (-) Sense (+) Sense Phase B Chassis Signal Return Inhibit
Page 6 of 7 Oct 20, 2022 | Rev (k) | Doc: DS_M186 Series M186 SERIES THREE-PHASE AC/DC POWER SUPPLY Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in Outline Drawing Heat Dissipation Surface Notes 1. Dimensions are in inches [mm] 2. Tolerance is: .XX 0.025 in .XXX 0.010 in 3. Weight: Approx. 4.4 lbs [2 kg] Dissipation Area 40.08 in² (258.6 cm²)
Page 7 of 7 Oct 20, 2022 | Rev (k) | Doc: DS_M186 Series M186 SERIES THREE-PHASE AC/DC POWER SUPPLY Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in Standard Configurations Part number Input Output Voltage range Frequency Voltage Current M186-100 3-phase, 103 to 127 VAC 400 Hz 12 VDC 70 A M186-101 3-phase, 103 to 127 VAC 400 Hz 15 VDC 70 A M186-102 3-phase, 103 to 127 VAC 400 Hz 24 VDC 70 A M186-103 3-phase, 103 to 127 VAC 400 Hz 28 VDC 70 A M186-104 3-phase, 103 to 127 VAC 400 Hz 36 VDC 55 A M186-105 3-phase, 103 to 127 VAC 400 Hz 48 VDC 40 A Note: Specifications are subject to change without prior notice by the manufacturer