Page 1 of 8 Oct 18, 2021 | Rev g | Doc: DS_M1802 Series M1802 SERIES DC/DC POWER SUPPLY Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in M1802 SERIES DC/DC POWER SUPPLY PRODUCT HIGHLIGHTS
- MINIATURE
- HIGH DENSITY
- EIGHT OUTPUT
- DC/DC POWER SUPPLY
- UP TO 150 W
Page 2 of 8 Oct 18, 2021 | Rev g | Doc: DS_M1802 Series M1802 SERIES DC/DC POWER SUPPLY Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in
Applications
Military (Airborne, ground-fix, shipboard), Ruggedized, Telecom, Industrial Power Supply Special Features
- Miniature size
- High efficiency
- High Density
- Wide input range
- Input / Output isolation
- TTL logic enable
- Output voltage calibration
- Current limit calibration
- Fixed switching freq (250 kHz)
- External sync capability
- EMI filters included
- Non-latching protections: o Overload o Short circuit o Output Over Voltage o Over Temperature Electrical Specifications DC Input Voltage range: 18 to 70 VDC, IAW MIL-STD-704A DC Output Please see Outputs Configuration Range below. Isolation Input to Output: 200 VDC Input to Case: 200 VDC Output to Case:
100 VDC
No damage due to overvoltage transients IAW: MIL-STD-1275A (100 V for 50 ms) MIL-STD-704A (80 V for 0.1 s) Line/Load regulation Efficiency EMC Better than ±1% (no load to full load, –55 C to +85 C and over Typical 80% - (full load, room temperature) Designed to meet MIL-STD- 461F* input voltage range). CE101, CE102, CS101, CS114, CS115, CS116, RE101, RE102, RS101, RS103 Ripple and Noise Transient Over-and-undershoot Turn on Transient Less than 50 mVp-p, typical (max. Output change at load transient Voltage overshoot at during 1%) without external of 30%-100% with Tr & Tf of max power on is less than 1% nominal capacitance. When connected to 30 μs is 5% of output voltage. voltage. system capacitance ripple drops Output recover to steady stated significantly. within less 0.5 ms. * EMC compliance achieved when tested with 5 μH LISNs, shielded harness and static resistive load.
Page 3 of 8 Oct 18, 2021 | Rev g | Doc: DS_M1802 Series M1802 SERIES DC/DC POWER SUPPLY Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in Protections * Input
- Under Voltage Lockout Turn off below 16 VDC. Turn on above 17 VDC..
- Over Voltage Lockout Turn off above 72 VDC. Turn on below 70 VDC. Output
- Over Voltage Protection Passive protection: Transorb selected at approx. 20% above nominal voltage.
- Current limiting Continuous protection (10-30% above maximum current) for unlimited time. General
- Over Temperature Protection Shutdown at base plate temperature of +105 C ± 5 C. Automatic recovery at base plate temperature lower than +95 C ± 5 C. Environmental Conditions Designed to Meet MIL-STD-810F Temperature Methods 501.4 & 502.4 Operating: –55 C to +85 C (at baseplate) Storage: –55 C to +125 C (ambient) Vibration Method 514.5 Procedure I Category 24 - General minimum integrity exposure Altitude Method 500.4 Procedures I – Storage/Air transport: up to 70 kft Procedure II – Operation/Air Carriage: up to 70 kft Shock Method 516.5 30 g, 11 ms terminal peak saw-tooth Humidity Method 507.4 Up to 95% RH Salt Fog Method 509.4 Reliability 150,000 hours, calculated IAW MIL-HDBK-217F Notice 2 at +85 C baseplate, Ground Fix conditions. Environmental Stress Screening (ESS) Including random vibration and thermal cycles is also available. Please consult factory for details. * Thresholds and protections can be modified / removed – please consult factory.
Page 4 of 8 Oct 18, 2021 | Rev g | Doc: DS_M1802 Series M1802 SERIES DC/DC POWER SUPPLY Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in Operational Block Diagram
Page 5 of 8 Oct 18, 2021 | Rev g | Doc: DS_M1802 Series M1802 SERIES DC/DC POWER SUPPLY Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in Outputs Configuration Range Output # Voltage Range Current Range Power Range 1 1.5 to 50 VDC 0 to 2.5 A 0 to 40 W 2 1.5 to 50 VDC 0 to 2.5 A 0 to 40 W 3 5 to 18 VDC 0 to 5 A 0 to 25 W 4 1.25 to 100 VDC 0 to 8 A 0 to 30 W 5 1.25 to 100 VDC 0 to 5 A 0 to 10 W 6 1 to 100 VDC 0 to 5 A 0 to 10 W 7 5 to 18 VDC 0 to 2.5 A 0 to 20 W 8 -5 to -18 VDC 0 to 2.5 A 0 to 20 W Total 0 to 150 W Outputs Isolation (Ground RTN groups)
- All outputs are isolated form the input.
- Outputs are separated into the following five galvanically isolated groups: o Group A: Output #1 o Group B: Output #2 o Group C: Output #3 o Group D: Outputs #4, #5 and #6 o Group E: Output #7, #8
Page 6 of 8 Oct 18, 2021 | Rev g | Doc: DS_M1802 Series M1802 SERIES DC/DC POWER SUPPLY Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in Pin Assignment Connector type: M55302/61A36 or eq. Mates with: M55302/62-A36M (solder cup termination) or M55302/66-36M (#22 AWG crimp termination) or eq. Pin No. Function P Pin No. Function P
1 OUT 3 +
19 OUT 3 RTN –
2 OUT 3 +
20 OUT 3 RTN –
3 OUT 2 RTN –
21 SIGNAL RTN –
4 OUT 2 +
22 INHIBIT +
5 OUT 8 –
23 SYNC +
6 OUTS 7, 8 RTN
24 SENSE 4 RTN –
7 OUT 1 RTN –
25 SENSE 4 +
8 OUT 7 +
26 OUT 1 +
9 OUT 1 +
27 INPUT RTN –
10 INPUT RTN –
28 INPUT RTN –
11 INPUT RTN –
29 INPUT +
12 INPUT +
30 INPUT +
13 INPUT +
31 OUT 4 +
14 OUT 4 +
32 OUT 4 +
15 OUTS 4, 5, 6
33 OUTS 4, 5, 6
16 OUTS 4, 5, 6
34 OUTS 4, 5, 6
17 OUT 5 +
35 OUT 5 +
18 OUT 6 +
36 OUT 6 +
Page 7 of 8 Oct 18, 2021 | Rev g | Doc: DS_M1802 Series M1802 SERIES DC/DC POWER SUPPLY Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in Signals Description SENSE 4 (pin 25) The SENSE 4 line is used to achieve accurate voltage regulation at load 4 terminals. To use this feature, connect this pin directly to load 1's positive terminal. If this function is not required, short SENSE 4 to OUT 4 (pins 14, 31 and 32) as close as possible to the connector. SENSE 4 RTN (pin 24) The SENSE 4 RTN line is used to achieve accurate voltage regulation at load terminals. To use t his feature, connect this pin directly to load's negative terminal. If this function is not required, short SENSE 4 RTN to OUT 4 RTN (pins 15, 16, 33 and 34) as close as possible to the connector. This signal is referenced to OUTS 4, 5, 6 RTN. Note: The use of remote sense has a limit of voltage dropout between the converter's output and the load's terminals of approximately 5% of nominal output voltage or 0.5 V – the lesser of the two. INHIBIT (pin 22) The INHIBIT signal is used to turn the power supply ON and OFF. TTL “1” or OPEN – Power supply active (output turned on). TTL “0” or SHORT to SIGNAL RTN – Power supply inhibited (output turned off). If this function is not required, leave this pin unconnected. This signal is referenced to SIGNAL RTN (pin 21) SYNC (pin 23) The SYNC signal is used to synchronize the power supply's switching frequency to system's clock. Valid external clock frequency is 250 kHz ± 10 kHz, and duty cycle is 50% ± 10%. If this function is not required, leave this pin unconnected - the power supply will use its internal clock. This signal is referenced to SIGNAL RTN (pin 21) SIGNAL RTN (pin 21) Both INHIBIT and SYNC signals are referenced to this pin. This pin is referenced to INPUT RTN (pins 10, 11, 27 and 28).
Page 8 of 8 Oct 18, 2021 | Rev g | Doc: DS_M1802 Series M1802 SERIES DC/DC POWER SUPPLY Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in Outline Drawing Notes 1. Dimensions are in inches [mm] 2. Tolerance is: .XX 0.01 in .XXX 0.005 in 3. Weight: Approx. 14 oz [400 g] Note: Specifications are subject to change without prior notice by the manufacturer