Page 1 of 11 Sep 4, 2023 | Rev (s) | Doc: DS_M169 Series M169 Series– AC/DC Power Supply Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in M169 SERIES SINGLE-OUTPUT, UP TO 1KW AC/DC POWER SUPPLY The M169 is a series of mechanically robust, base plate cooled, high performance, 1kW single output AC to DC power supplies, for Navy shipboard, Airborne, and ground applications. The M169 converts 85 VAC -265 VAC /50-60Hz or 85 VAC -150 VAC /400Hz, to a well-regulated, filtered and protected DC Output.
Page 2 of 11 Sep 4, 2023 | Rev (s) | Doc: DS_M169 Series M169 Series– AC/DC Power Supply Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in THE MAIN FEATURES OF THE M169 ARE: ➢ AC/DC Single output power supply up to 1kW ➢ 85VAC -265VAC /50-60Hz or 85VAC -150VAC / 400Hz Standard Input version, single-phase ➢ For extended input version - Please contact factory for more details ➢ High efficiency ➢ Wide input range ➢ High power factor ➢ Input / Output isolation ➢ Remote sense compensation ➢ Remote Inhibit (On/Off) ➢ External sync. capability ➢ EMI filters included ➢ Inrush Current Limiter ➢ Non-latching protections: o Overload/Short-circuit o Output Overvoltage o Over Temperature o Input Undervoltage Lockout
Page 3 of 11 Sep 4, 2023 | Rev (s) | Doc: DS_M169 Series M169 Series– AC/DC Power Supply Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in Standard Models List (for other voltages – consult factory) Part number Input Output Special features Voltage range Frequency Voltage Curr ent M169-100 85-265VAC/Single phase 50/60/400Hz 5 VDC 70 A M169-101 85-265VAC/Single phase 50/60/400Hz 12 VDC 70 A M169-102 85-265VAC/Single phase 50/60/400Hz 24 VDC 42 A M169-103 85-265VAC/Single phase 50/60/400Hz 28 VDC 36 A M169-104 85-265VAC/Single phase 50/60/400Hz 48 VDC 21 A M169-105 85-265VAC/Single phase 50/60/400Hz 270 VDC 4 A M169-106 85-265VAC/Single phase 50/60/400Hz
28 VDC 36 A
Parallel operation via output voltage droop. Voltage regulation is ±2%.. M169-107 85-265VAC/Single phase 50/60/400Hz 48 VDC 21 A Parallel operation via output voltage droop. Voltage regulation is ±2%.. M169-108 85-265VAC/Single phase 50/60/400Hz 24 VDC 42 A Parallel operation via output voltage droop. Voltage regulation is ±2%..
- Additional standard configurations available. Contact factory for more details.
- All of our products can be configured to comply with EU REACH regulations. Contact factory for more details.
Page 4 of 11 Sep 4, 2023 | Rev (s) | Doc: DS_M169 Series M169 Series– AC/DC Power Supply Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in SPECIFICATIONS: AC Input Voltage Range Option 1: 85 VAC -265 VAC /50 Hz - 60 Hz / Single-phase Option 2: 85 VAC -150 VAC /400 Hz / Single-phase For extended input version - Please contact factory for more details Isolation 1 000 VDC Input to Output 1 000 VDC Input and Case Spikes Optional to withstand 1000 V spikes IAW MIL-STD-1399-300B. please consult factory DC Output Rating See table on page 8 Voltage Regulation Up to ±1% (no load to full load, –40 C to +85 C and over normal input voltage range). Remote Sense The SENSE is used to achieve accurate load regulations at load terminals (this is done by connecting the pins directly to the load’s terminals). For output voltage above 8V, the use of remote sense has a max limit of 0.25V voltage dropout between converter’s output and load terminals. For output voltage below 8V, the use of remote sense has a max limit of 0.5V voltage dropout between converter’s output and load terminals. When not used connect SENSE to OUT and SENSE RTN to OUT RTN. Ripple and Noise (max. 1%) measured at load across 1 μF and 0.1 μF ceramic capacitors. Isolation 200 VDC Output and Case. (At M169-105 it is 500VDC) Current Limit & Overload Output turns off and on periodically (hiccup) until fault is condition removed. Protection threshold set at 120% ± 10% of maximum current Efficiency Up to 85-87% - typical (nominal input voltage, full load, room temperature) Overvoltage Protection Active Over-Voltage Protection Internal control shuts output down if voltage exceeds 110% 5% of nominal. Passive Over-Voltage Protection A transorb, rated to 120% 10% of nominal voltage, is placed across the output Over Temp. Protection Unit shuts down if baseplate temperature exceeds 100 ± 5 C. Automatic recovery upon cooldown to below 90 ± 5 C.
Page 5 of 11 Sep 4, 2023 | Rev (s) | Doc: DS_M169 Series M169 Series– AC/DC Power Supply Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in Specifications (Cont.): Control & Indication ON/OFF input The INHIBIT IN signal is used to turn the power supply ON and OFF. TTL “1”or OPEN – will turn on the power supply. (For normal operation leave the signal not connected.) TTL “0” – will turn off the power supply. Ground reference for the INHIBIT IN signal is SIGNAL RTN (pin #1). Optional on/off ENABLE IN signal - Please consult factory: TTL “0”or OPEN – will turn on the power supply. (For normal operation leave the signal not connected.) TTL “1” – will turn off the power supply. Ground reference for the ENABLE IN signal is SIGNAL RTN (pin #1). INHIBIT OUT Used when connecting two units or more in parallel. Connect this signal to the INHIBIT IN pin of the slave unit (see diagram below). This signal synchronizes the shutdown and startup of the units. SYNC IN The SYNC IN signal is used to allow the power supply frequency to sync with the system frequency. The system frequency should be 250 kHz ± 10 kHz. When not connected the power supply will work at 250 kHz ± 10 kHz. SYNC OUT The SYNC OUT signal is used to sync the system with the power supply frequency. SIGNAL RTN The SIGNAL RTN is a floated ground. This pin is used as ground return for SYNC IN, SYNC OUT, INHIBIT IN and INHIBIT OUT signals. Environment Designed to meet MIL- STD-810F Temperature Methods 501.4 & 502.4 Operating: –40 C to +85 C (at baseplate) Storage: –55 C to +125 C (ambient) Humidity Method 507.4 Procedure I Up to 95% RH Salt-fog Method 509.5 Altitude Method 500.4 Procedures I – up to 70,000 ft. (non-operational) Procedure II – up to 40,000 ft. (operational)
Page 6 of 11 Sep 4, 2023 | Rev (s) | Doc: DS_M169 Series M169 Series– AC/DC Power Supply Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in Mechanical Shock Method 516.5 Procedure I 30 g, 11 ms terminal peak saw-tooth Vibration Method 514.5 Procedure I Category 24 - General minimum integrity exposure Fungus Does not support fungus growth, in accordance with the guidelines of MIL-STD-454, Requirement 4 EMI MIL-STD-461F Designed to meet* MIL-STD-461F CE101, CE102, CS101, CS114, CS115, CS116, RE101, RS101, RS103 Reliability 150,000 hours, calculated per MIL-STD-217F Notice 2 at +85 C baseplate, Ground Fixed environment. Form factor 5.51'' wide, 1.50'' high and 9.84'' deep. For detailed dimensions and tolerances see Drawing: M169001 Weight 1.92kg (4.25lbr) Connectors See Page 9-11 *Compliance achieved with shielded harness and static resistive load.
Page 7 of 11 Sep 4, 2023 | Rev (s) | Doc: DS_M169 Series M169 Series– AC/DC Power Supply Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in TYPICAL STAND-ALONE CONNECTION DIAGRAM M169 Phase (-) VOUT RTN (+) VOUT Load Signal RTN (-) Sense RTN (+) Sense Neutral Chassis Inhibit In Inhibit Sync In Sync Out Inhibit Out Sync EMI Filter (optional) Input Voltage Optional TYPICAL PARALLEL CONNECTION DIAGRAM M169 Phase (-) VOUT RTN (+) VOUT Load Signal RTN (-) Sense RTN (+) Sense Neutral Chassis Inhibit In Sync In Sync Out Inhibit Out EMI Filter (optional) Input Voltage Optional M169 Phase (-) VOUT RTN (+) VOUT Signal RTN (-) Sense RTN (+) Sense Neutral Chassis Inhibit In Sync In Sync Out Inhibit Out 1µF Sync Inhibit
Page 8 of 11 Sep 4, 2023 | Rev (s) | Doc: DS_M169 Series M169 Series– AC/DC Power Supply Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in PIN ASSIGNMENT: J1 - INPUT CONNECTOR Connector type: M24308/24-38F or eq. Mates with: M24308/2-2F or eq. Pin # Function P Pin # Function P Pin # Function P 1 PHASE ~ 6 NEUTRAL 0 11 N.C. 2 PHASE ~ 7 N.C. 12 NEUTRAL 0
3 PHASE ~ 8 CHASSIS 13 NEUTRAL 0
4 N.C. 9 PHASE ~ 14 NEUTRAL 0 5 NEUTRAL 0 10 PHASE ~ 15 N.C. Note: All pins with identical function/designation should be connected together for optimal performance. CHASSIS Note: Chassis PIN This pin is connected to the converter's chassis.
Page 9 of 11 Sep 4, 2023 | Rev (s) | Doc: DS_M169 Series M169 Series– AC/DC Power Supply Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in PIN ASSIGNMENT: J2 - OUTPUT CONNECTOR Connector type: M24308/23-41F or eq. Mates with: M24308/4-5F or eq. Pin # Function P Pin # Function P Pin # Function P
1 SIGNAL RTN – 18 INHIBIT OUT + 35 INHIBIT IN +
2 SYNC OUT + 19 SENSE RTN – 36 N.C.
3 SENSE + 20 OUT + 37 OUT +
4 OUT + 21 OUT + 38 OUT +
5 OUT + 22 OUT + 39 OUT +
6 OUT + 23 OUT + 40 OUT +
7 OUT + 24 OUT + 41 OUT +
8 OUT + 25 OUT + 42 OUT +
9 OUT + 26 OUT + 43 OUT +
10 OUT + 27 OUT RTN – 44 OUT RTN –
11 OUT RTN – 28 OUT RTN – 45 OUT RTN –
12 OUT RTN – 29 OUT RTN – 46 OUT RTN –
13 OUT RTN – 30 OUT RTN – 47 OUT RTN –
14 OUT RTN – 31 OUT RTN – 48 OUT RTN –
15 OUT RTN – 32 OUT RTN – 49 OUT RTN –
16 OUT RTN – 33 OUT RTN – 50 OUT RTN –
17 OUT RTN – 34 SYNC IN +
Note: All pins with identical function/designation should be connected together for optimal performance. CHASSIS Note: Chassis PIN This pin is connected to the converter's chassis.
Page 10 of 11 Sep 4, 2023 | Rev (s) | Doc: DS_M169 Series M169 Series– AC/DC Power Supply Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in HV option: High voltage version (100 to 300 VDC) Pin # Function P Pin # Function P Pin # Function P 2 SYNC OUT + 19 N.C. – 36 N.C. 3 N.C. + 20 OUT + 37 OUT + Note: All pins with identical function/designation should be connected together for optimal performance. CHASSIS Note: Chassis PIN This pin is connected to the converter's chassis.
Page 11 of 11 Sep 4, 2023 | Rev (s) | Doc: DS_M169 Series M169 Series– AC/DC Power Supply Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in OUTLINE DRAWING: For detailed dimensions and tolerances see Drawing: M169001 HEAT DISSIPATION SURFACE: Note: Specifications are subject to change without prior notice by the manufacturer. Notes 1. Dimensions are in inches [mm] 2. Tolerance is: .XX .02 in .XXX .01 in 3. Weight: 4.25 lbs [1 922 g] Dissipation Area 21.08 in² (13,600 mm²)