Page 1 of 4 Oct 18, 2021 | Rev e | Doc: DS M167 Series M167 SERIES 3-PHASE AC/DC POWER SUPPLY Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in M167 SERIES 3-PHASE AC/DC POWER SUPPLY PRODUCT HIGHLIGHTS

  • COMPACT
  • HIGH DENSITY
  • HIGH EFFICIENCY
  • SINGLE OUTPUT
  • AC/DC POWER SUPPLY
  • UP TO 1600 W

Page 2 of 4 Oct 18, 2021 | Rev e | Doc: DS M167 Series M167 SERIES 3-PHASE AC/DC POWER SUPPLY Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in

Applications

Military (Airborne, ground-fix, shipboard), Ruggedized, Telecom, Industrial Special Features

  • High efficiency
  • Wide input range
  • Input / Output isolation
  • Limited Inrush Current
  • Fixed switching frequency
  • EMI filters included
  • Indefinite short circuit protection with auto-recovery
  • Over-voltage shutdown with auto-recovery
  • Over temperature shutdown with auto-recovery Electrical Specifications AC Input Range: 115V/400 Hz (320-520Hz), 3-phase per MIL-STD-704A/D DC Output: Voltage: 3.3V to 50V Current: Up to 55A Power: Up to 1.6kW Isolation: 500V between Input and Output 500V between Input and Case 100V between Output and Case Line/Load regulation: Less than 1% (no load to full load, –40C to +71C). Efficiency: 85% - minimum (full load, room temperature) EMC: Designed to meet MIL-STD- 461F at 45A: CE102, CS101, CS114, CS115, CS106, RE101, RE102, RS101, RS103 Ripple and Noise: 100150mVp-p, typical (max. 1%) without external capacitance. When connected to system capacitance ripple drops significantly. Turn on Transient No Voltage over shoot during power on. Protections * Input
  • Inrush Current Limiter peak value of 6 x IIN Output
  • Passive transorb on outputs 20% above nominal voltage.
  • Current limiting Continuous protection (10-30% above maximum current) for unlimited time. General
  • Over temperature protection: Shutdown at base plate temperature of +105C (5C) Automatic recovery at base plate temperature lower than +95C (5C) * Thresholds and protections can be modified / removed – please consult factory.

Page 3 of 4 Oct 18, 2021 | Rev e | Doc: DS M167 Series M167 SERIES 3-PHASE AC/DC POWER SUPPLY Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in Environmental Designed to meet MIL-STD- 810E Temperature: Operating: –40C to +71C (at Altitude: Method 500.4, Procedure I & II, Salt Fog: Method 509-4 base plate) Storage: –55C to +125C 40,000 ft. and 70,000 ft. Operational Reliability Humidity: Vibration and Shock: Min 50,000 hours, calculated per MIL-STD-217F at +70C base Method 507.4 - Up to 95%. Shock - Sow-tooth, 20g peak, 11mS. plate, Ground fixed. Note: at 100C base plate MTBF Vibration - method 514.6, proc. I. will be lower and method 519.6, proc. I Environmental Stress Screening (ESS) Including random vibration and thermal cycles is also available. Please consult factory for details. Pin Assignment (Input Connector) Pin No. Function Pin No. Function

1 CHASSIS 9 PHASE A

2 PHASE A 10 PHASE A

3 N.C. 11 N.C.

4 PHASE B 12 PHASE B

5 PHASE B 13 N.C. 6 N.C. 14 PHASE C

7 PHASE C 15 PHASE C

8 N.C. Pin Assignment (Output Connector) Pin No. Function Pin No. Function Pin No. Function Pin No. Function 1 - OUT 12 - OUT 23 + OUT 34 + OUT

2 INHIBIT 13 - OUT 24 - OUT 35 + OUT

3 + OUT 14 - OUT 25 - OUT 36 + OUT 4 + OUT 15 - OUT 26 - OUT 37 + OUT 5 + OUT 16 + OUT 27 - OUT 38 + OUT 6 + OUT 17 + OUT 28 - OUT 39 - OUT 7 + OUT 18 + OUT 29 - OUT 40 - OUT 8 + OUT 19 + OUT 30 - OUT 41 - OUT 9 - OUT 20 + OUT 31 -INHIBIT 42 - OUT 10 - OUT 21 + OUT 32 + OUT 43 - OUT 11 - OUT 22 + OUT 33 + OUT 44 - OUT

  • All output parallel pins should be connected together for best performance.

Page 4 of 4 Oct 18, 2021 | Rev e | Doc: DS M167 Series M167 SERIES 3-PHASE AC/DC POWER SUPPLY Switzerland sales@enercon-europe.com Israel sales@enercon.co.il India sales@mpsindia.in Functions and Signals INHIBIT signal The INHIBIT signal is used to turn the power supply ON and OFF. OPEN – will turn on the power supply. SHORT – between pin 2 and pin 31 will turn off the power supply. Outline Drawing

  • Specifications are subject to change without prior notice by the manufacturer N o t e s
  • Dimensions are in Inches [mm]
  • Tolerance is: XX .02 IN .XXX .01 IN
  • Weight: 1,600gr (preliminary)
  • Parasolid 3D module is available